DOB11/17/2025EMERGENCY WORK ORDER DUE TO OPEN/EXPOSED MASONRY SECTION WITH LOOSE WOOD INSIDE, CRACKED/SPALLING STUCCO AND CRACKING IN MASONRY/STONES AT EXPOSURE #2 SOUTH ELEVATION. REMEDY: IMMEDIATELY PROVIDE SAFETY MEASURES AT EXPOSURE #2 SOUTH ELEVATION TO COVER FULL EXPOSURE UNDER DIRECTION OF A LICENSED PROFESSIONAL
DOB11/17/2025FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AS PER SECTION 28-301.1 OF NYC ADMIN CODE. AS NOTED AT TIME OF INSPECTION OBSERVED AT EXPOSURE 2 EXPOSED BRICK WORK AND CRACKS IN MASONRY. REMEDY: REPAIR AND/OR REPLACE
ECB04/15/2025FAILED TO CERTIFY FOR CORRECTION FOR SUMMONS #39065450H, FILE A CERTIFICATE OF CORRECTION$6K due
DOB09/16/2022FAILURE TO COMPLY W/COMMISSIONER'S ORDER 340793(070822FEU30612ZT)DATED 07/08/22 REQUIRING THE OWNER TO START BLDG REPAIRS UNDER PERMIT FOR THE DAMAGED FACADE. AS OF 09/16/22 THERE ARE NO JOBS FILED IN BIS OR DOB NOW TO REPAIR THE BLDG. REMEDY: IMMED COMPLY W/COMMISSIONER'S ORDER 340793(070822FEU30612ZT)TO REPAIR THE BLDG UNDER PERMIT
DOB07/08/2022INSTALL APPROXIMATELY 26 FEET OF SIDEWALK SHED COVERING THE ENTIRE FRONT OF THE BUILDING(COURT STREET SIDE)WITH THE 5FT EXTENSION EXTENDE D TO THE FRONT OF 228 COURT STREET IN ORDER TO PROTECT THE PEDESTRIAN BELOW
DOB07/08/2022FAIL TO MAINTAIN-EXP1 FACADE FACE BRCKS APPEARD LOOSE,BULGNG OUTWARD & DTACHING FROM BACK UP WALLS(INTERIOR WALL).HORZNTL,VERT &DIAGONAL CRACKS OBSRVD ON EXP1 & EXP2 FACADE WALL OWNR RTAIN NYSPE-EVALU ENTIRE BLDG &PREPARE/FILE RPR DWGS RPRS STRT UNDR PRMT BY 8/15/22 &COMPLT/SIGND OFF BY 10/19/22
DOB07/08/2022ATOI, THE FACADES AT EXPS #'S 1 & 2 EXHIBITS EXCESSIVE VERT, HORIZ & DIAGONAL CRACKS. THE STUCCO VENEER IS BOWING OUTWARDLY & SEVERELY CRACKED & FLAKING AT THE 2ND & 3RD FLRS WINDOW LINTEL & SILL TOWARDS ADJOINING BLDGN 228 CRT STR WITH THE POSSIBILITY OF COLLAPSE UNTO PEDESTRIANS TRAVERSING BELOW ON THE PUBLIC THOROUGHFARE/SIDEWALK AT
ECB05/14/2024FAILURE TO SIGN OFF PERMITTED JOB REQUIRED BY DEPARTMENT OF BUILDINGS (DOB). DOB RECORD SHOWS THAT WORK UNDER JOB# 320591338 NOT SIGNED OFF, PERMIT EXPIRED. 28-116.4; 28-116.4, COMPLY WITH CODENothing owed — awaiting certificate of correction
ECB07/07/2022FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES; NOTED: OBSERVED CRACKS WITH BULGING AT THE FRONT EXTERIOR FACADE WALL. THIS IS A POTENTIAL FALL HAZARD., MAINTAIN EXTERIOR BUILDING WALLNothing owed — awaiting certificate of correction