← Back
Miscellaneous asylum / home
City Wide Supportive
2303 ANDREWS AVENUE NORTH · BIN 2114464
💬 Discuss this project
2003Year Built
6Stories
N9Building Class
R7-1Zoning
31,770 sfGross Floor Area
27Units
LL97 CoveredRent Stabilized0 Open Violations
Miscellaneous asylum / home · Owner of record: CITY WIDE SUPPORTIVE HOUSING INC · 10,375 sf lot · 3.06 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Roof26p · 1 filing · 20 docs
Floor 623p · 1 filing · 20 docs
Floor 521p · 1 filing · 20 docs
Floor 422p · 1 filing · 20 docs
Floor 322p · 1 filing · 20 docs
Floor 222p · 1 filing · 20 docs
Floor 128p · 1 filing · 20 docs
Cellar25p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HKS CONSTRUCTION407/08/2026
NEW DESTINY HOUSING2807/08/2026
CITY WIDE SUPPORTIVE HOUSING703/22/2026
OWNER OF : 2303 ANDREWS A203/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING1403/21/2026
P WOLFE CONSULTANTS803/21/2026
A1 EXPEDITING SERVICE203/21/2026
HAIDER ENGINEERING, P.E.103/21/2026
HAIDER ENGINEERING P E103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MICHAEL BORRUTO GENERAL CONTR.General Contractor807/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing307/08/2026
QUEENSBORO ELEC'L CONTR'GElectrical203/22/2026
AMERICAN STANDARD PLUMBING &Fire Protection207/08/2026
ARSENAL SCAFFOLD INCGeneral Contractor107/08/2026
HKS CONSTRUCTION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
VIBRANALYSIS INC., DBA VT6864909/18/2024
Building Lifecycle
All (149)Filed (13)Permit Issued (12)Signed Off (6)Violation (49)Inspection (15)Objection (24)Special Inspection (30)
06/16/2025
Violation issued (HPD, closed)
A
03/07/2025
Signed off — Alteration CO
Propose to add concrete on top of existing metal deck over the existing roof structure of the extension and dunnage as per plan in conjunction with Alt-CO-GC # X00675174-I1.
X00675174-S5
03/06/2025
Signed off — Alteration CO
Propose to add concrete on top of existing metal deck over the existing roof structure of the extension and dunnage as per plan in conjunction with Alt-CO-GC # X00675174-I1.
X00675174-S1
01/10/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/01/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/26/2024
Signed off — Alteration CO
Propose to add concrete on top of existing metal deck over the existing roof structure of the extension and dunnage as per plan in conjunction with Alt-CO-GC # X00675174-I1.
X00675174-S2
11/11/2024
Filed — Alteration CO
Propose to add concrete on top of existing metal deck over the existing roof structure of the extension and dunnage as per plan in conjunction with Alt-CO-GC # X00675174-I1.
X00675174-P5
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/18/2024
Filed — Alteration CO
Propose to add concrete on top of existing metal deck over the existing roof structure of the extension and dunnage as per plan in conjunction with Alt-CO-GC # X00675174-I1.
X00675174-P3
09/18/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/18/2024
Special inspection requirement — Maintenance information
JUAN GOMEZ
09/18/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
JUAN GOMEZ
09/18/2024
Special inspection requirement — HVAC-R and service water heating system controls
JUAN GOMEZ
09/18/2024
Special inspection requirement — Energy Code Compliance Inspections
JUAN GOMEZ
09/18/2024
Special inspection requirement — HVAC-R and service water heating equipment
JUAN GOMEZ
09/18/2024
Special inspection requirement — Final
JUAN GOMEZ
09/18/2024
Special inspection requirement — Heating Systems
JUAN GOMEZ
09/18/2024
Special inspection requirement — Shutoff dampers
JUAN GOMEZ
09/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JUAN GOMEZ
09/18/2024
Special inspection requirement — Mechanical Systems
JUAN GOMEZ
09/12/2024
Signed off — Alteration CO
Propose to add concrete on top of existing metal deck over the existing roof structure of the extension and dunnage as per plan in conjunction with Alt-CO-GC # X00675174-I1.
X00675174-S3
09/10/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
JUAN GOMEZ
09/10/2024
Special inspection requirement — Energy Code Compliance Inspections
JUAN GOMEZ
09/10/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JUAN GOMEZ
09/10/2024
Special inspection requirement — Air barrier - visual inspection
JUAN GOMEZ
09/10/2024
Special inspection requirement — Fenestration air leakage
JUAN GOMEZ
09/10/2024
Special inspection requirement — Fenestration areas
JUAN GOMEZ
09/10/2024
Special inspection requirement — Insulation placement and R values
JUAN GOMEZ
09/10/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
JUAN GOMEZ
09/06/2024
Filed — Alteration CO
Propose to add concrete on top of existing metal deck over the existing roof structure of the extension and dunnage as per plan in conjunction with Alt-CO-GC # X00675174-I1.
X00675174-P4
09/03/2024
Special inspection requirement — Air barrier - visual inspection
JUAN GOMEZ
09/03/2024
Special inspection requirement — Energy Code Compliance Inspections
JUAN GOMEZ
09/03/2024
Special inspection requirement — Fenestration air leakage
JUAN GOMEZ
09/03/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JUAN GOMEZ
09/03/2024
Special inspection requirement — Insulation placement and R values
JUAN GOMEZ
09/03/2024
Special inspection requirement — Fenestration areas
JUAN GOMEZ
09/03/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
JUAN GOMEZ
09/03/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
JUAN GOMEZ
08/23/2024
Special inspection requirement — HVAC-R and service water heating equipment
JUAN GOMEZ
08/23/2024
Special inspection requirement — HVAC-R and service water heating system controls
JUAN GOMEZ
08/23/2024
Special inspection requirement — Energy Code Compliance Inspections
JUAN GOMEZ
08/23/2024
Special inspection requirement — Shutoff dampers
JUAN GOMEZ
08/07/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/06/2024
Objection resolved — Addressed
08/02/2024
Objection raised — Admin
07/31/2024
Filed — Alteration CO
Propose to add concrete on top of existing metal deck over the existing roof structure of the extension and dunnage as per plan in conjunction with Alt-CO-GC # X00675174-I1.
X00675174-P2
07/12/2024
Signed off — Alteration
X00147439-I1
07/10/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
06/28/2024
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
06/27/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
06/24/2024
Filed — Alteration CO
Propose to add concrete on top of existing metal deck over the existing roof structure of the extension and dunnage as per plan in conjunction with Alt-CO-GC # X00675174-I1.
X00675174-P1
06/17/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
06/07/2024
Signed off — Alteration
HEAVY DUTY SIDEWALK SHED DURING BLDG ALTERATION, FILED SEP. SIDEWALK SHED SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
X00959945-I1
06/07/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
06/05/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/05/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/02/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/10/2024
Permit issued — Sprinklers
X00675174-S3-EW-SP
Latest 60 of 149 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offAMERICAN STANDARD PLUMBIN04/10/2024
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.02/27/2024
DOB NOWBoiler EquipmentSigned-offAMERICAN STANDARD P&H CORORP.02/21/2024
DOB NOWMechanical SystemsSigned-offMICHAEL BORRUTO GENERAL C12/08/2023
DOB NOWGeneral ConstructionPermit IssuedMICHAEL BORRUTO GENERAL C12/08/2023
DOB NOWSidewalk ShedSigned-offARSENAL SCAFFOLD INC11/13/2023
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.03/28/2023
DOB NOWSprinklersSigned-offAMERICAN STANDARD PLUMBIN03/28/2023
DOB NOWStructuralPermit IssuedMICHAEL BORRUTO GENERAL C01/19/2023
DOB NOWGeneral ConstructionPermit IssuedMICHAEL BORRUTO GENERAL C01/19/2023
DOB NOWMechanical SystemsSigned-offMICHAEL BORRUTO GENERAL C01/19/2023
DOB NOWSidewalk ShedSigned-offHKS CONSTRUCTION CORP03/28/2019
BISCCISSUEDPHOENIX BUILDERS05/01/2006
BISEQISSUEDPHOENIX BUILDERS,INC03/29/2005
BIS—ISSUEDPHOENIX BUILDERS,INC03/29/2005
BISEQISSUEDPHOENIX BUILDERS,INC12/03/2004
BISSDISSUEDRO-SAL PLBG HTG INC08/23/2004
BISPLISSUEDRO-SAL PLUMBING & HTG INC INC.08/23/2004
BISEQISSUEDPHOENIX BUILDERS,INC03/27/2004
BIS—ISSUEDPHOENIX BUILDERS,INC03/27/2004
BISSPISSUEDRO-SAL PLBG HTG INC08/22/2003
BISPLISSUEDRO-SAL PLUMBING & HTG INC INC.06/27/2003
BIS—ISSUEDPHOENIX BUILDERS,INC06/16/2003
BIS—ISSUEDPHOENIX BUILDERS,INC03/11/2003
BISEQISSUEDPHOENIX BUILDERS,INC03/11/2003
BISEQISSUEDPHOENIX BUILDERS,INC01/06/2003
BIS—ISSUEDPHOENIX BUILDERS,INC10/17/2002
1 project · most recent 11/11/2024
Air Conditioning Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/11/2024Permit IssuedMICHAEL BORRUTO GENERAL CAir Conditioning Systems, Heating and Air Conditioning Systems, Ventilation Systems
Cooling
York ZE072J12D2C6LAA2B1 73,400 BTU · Packaged Unit ×2
Heat / Cool
Mitsubishi Electric PURY-P72TNU-A 72,000 BTU · Vrf Outdoor ×2
PUZ-A12NKA7 12,000 BTU · Condensing Unit ×2
Ventilation
Greenheck CUE-100HP-5-VG-1-19-X 400 CFM · Exhaust Fan ×2
ERVE-20-30L 2,025 CFM · Erv ×2
G-097-4-VG-1-19-X 100 CFM · Exhaust Fan ×2
1 project · most recent 11/11/2024
Sprinkler System
FiledStatusContractorScope
11/11/2024Signed-offAMERICAN STANDARD PLUMBINSprinkler System
1 project · most recent 11/11/2024
Gas Water/Sanitary
FiledStatusContractorScope
11/11/2024Signed-offAMERICAN STANDARD P&H CORGas, Water/Sanitary
3 projects · most recent 09/17/2024
General Wiring
FiledStatusContractorScope
09/17/2024CompleteQUEENSBORO ELEC'L CONTR'GGeneral Wiring
11/09/2023CompleteNASH ELECTRIC SERVICES IN—
04/08/2019CompleteRICHARD NEU—
1 project · most recent 11/11/2024
Steel Concrete
FiledStatusContractorScope
11/11/2024Signed-offAMERICAN STANDARD PLUMBINSteel, Concrete
▾Field Inspections (DOB CAP) — 15
DateTypeResultReport
01/10/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/18/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/07/2024Pass-Final CND-Occupancy InspectionPassView ↗
07/10/2024Fail-Final CND-Occupancy InspectionFailView ↗
06/28/2024Pass-Final Boiler Equipment InspectionPassView ↗
06/27/2024Fail-Final CND-Occupancy InspectionFailView ↗
06/17/2024Fail-Final CND-Occupancy InspectionFailView ↗
06/07/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
06/05/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/05/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/26/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/20/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/29/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/30/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/22/2023Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 64
DateRequirementInspectorRole
09/18/2024HVAC-R and service water heating equipmentJUAN GOMEZenergy_progress
09/18/2024Heating SystemsJUAN GOMEZspecial
09/18/2024Mechanical SystemsJUAN GOMEZspecial
09/18/2024Fire-Resistant Penetrations and JointsJUAN GOMEZspecial
09/18/2024Energy Code Compliance InspectionsJUAN GOMEZprogress
09/18/2024FinalJUAN GOMEZprogress
09/18/2024Shutoff dampersJUAN GOMEZenergy_progress
09/18/2024HVAC-R and service water piping design and insulationJUAN GOMEZenergy_progress
09/18/2024HVAC-R and service water heating system controlsJUAN GOMEZenergy_progress
09/18/2024Maintenance informationJUAN GOMEZenergy_progress
09/10/2024Structural Stability – Alterations of existing buildingsJUAN GOMEZspecial
09/10/2024Insulation placement and R valuesJUAN GOMEZenergy_progress
09/10/2024Fenestration areasJUAN GOMEZenergy_progress
09/10/2024Fenestration and door U-factor and product ratingsJUAN GOMEZenergy_progress
09/10/2024Air barrier - visual inspectionJUAN GOMEZenergy_progress
09/10/2024Energy Code Compliance InspectionsJUAN GOMEZprogress
09/10/2024Fire-Resistant Penetrations and JointsJUAN GOMEZspecial
09/10/2024Fenestration air leakageJUAN GOMEZenergy_progress
09/03/2024Fire-Resistant Penetrations and JointsJUAN GOMEZspecial
09/03/2024Fenestration and door U-factor and product ratingsJUAN GOMEZenergy_progress
09/03/2024Air barrier - visual inspectionJUAN GOMEZenergy_progress
09/03/2024Fenestration air leakageJUAN GOMEZenergy_progress
09/03/2024Insulation placement and R valuesJUAN GOMEZenergy_progress
09/03/2024Fenestration areasJUAN GOMEZenergy_progress
09/03/2024Energy Code Compliance InspectionsJUAN GOMEZprogress
Latest 25 of 64.
▾Documents — 104 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch11
08/21/2026X00675174-S2Request digital key ↗
08/21/2026X00675174-S4Request digital key ↗
08/21/2026X00675174-S5Request digital key ↗
Showing 3 of 11 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed1
08/26/2026X00147439-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X00675174-I1Open ↗
▸Seals & Professional Certifications68
▸DOB NOWProgress Inspector Seal & Signature36
09/23/2026X00675174-S5Open ↗
09/22/2026X00675174-P3Open ↗
09/22/2026X00675174-P3Open ↗
Showing 3 of 36 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature20
09/23/2026X00675174-S5Open ↗
09/22/2026X00675174-P3Open ↗
09/22/2026X00675174-P3Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/26/2026X00147439-I1Open ↗
08/13/2026X00675174-I1Open ↗
08/13/2026X00675174-S1Open ↗
Showing 3 of 12 on file for this type
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist3
08/13/2026X00675174-P2Open ↗
08/13/2026X00675174-P4Open ↗
08/13/2026X00675174-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026X00675174-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026X00675174-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X00675174-I1Open ↗
▸Energy Compliance4
▸DOB NOWPreliminary Commissioning Report Certification3
08/13/2026X00675174-S2Open ↗
08/13/2026X00675174-S1Open ↗
08/13/2026X00675174-S5Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026X00675174-I1Open ↗
▸Approvals, Objections & Sign-offs9
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter9
08/13/2026X00675174-P2Open ↗
08/13/2026X00675174-S4Open ↗
08/13/2026X00675174-S1Open ↗
Showing 3 of 9 on file for this type
▸Other Documents4
▸DOB NOWProperty Ownership Certification3
08/13/2026X00675174-I1Open ↗
08/13/2026X00675174-P4Open ↗
08/13/2026X00675174-P2Open ↗
▸DOB NOWBSA Meeting Minutes/BSA Resolution1
08/13/2026X00147439-I1Open ↗