← Back
Condo, residential unit, 1-3 unit building (orig. class 1)
231 BERGEN STREET
BROOKLYN · Downtown Brooklyn-DUMBO-Boerum Hill · BIN 3001396
💬 Discuss this project
1859Year Built
—Stories
R6Building Class
R6BZoning
4,183 sfGross Floor Area
3Units
1 Open Violation 0 unresolved · 1 paperwork only ▸
Condo, residential unit, 1-3 unit building (orig. class 1) · 2,000 sf lot · 2.09 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralOther
Site & exterior6p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
XINOS CONSTRUCTION1207/08/2026
5 TH AVENUE HOLDING1103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY RESTORATION TECHNOLOGY CORP209/13/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
XINOS CONSTRUCTION403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
XINOS CONSTRUCTION CORPGeneral Contractor707/08/2026
BUILDING RITEElectrical103/21/2026
SCHNEIDER, DANIELElectrical103/21/2026
Building Lifecycle
All (26)Filed (2)Permit Issued (4)Violation (18)Inspection (2)
06/01/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/17/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/07/2022
Permit issued — Supported Scaffold
B00185412-I1-SF
03/31/2022
Permit issued — Supported Scaffold
B00185412-I1-SF
03/14/2022
Violation issued (ECB, open)
Unknown
02/14/2020
Permit issued — Supported Scaffold
B00185412-I1-SF
09/19/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/13/2019
Filed — Alteration
SUPPORTED SCAFFOLD INSTALLATION LIMITED EXTERIOR AND ROOF LEVEL REPAIR INCLUDING REMOVAL AND REPLACEMENT OF EXISTING ROOFING SYSTEM AS PER DOB VIOLATION# 061819CCE0112G01.
B00185412-P1
09/11/2019
Violation issued (ECB, closed)
Construction
08/27/2019
Permit issued — Supported Scaffold
B00185412-I1-SF
08/26/2019
Filed — Alteration
SUPPORTED SCAFFOLD INSTALLATION LIMITED EXTERIOR AND ROOF LEVEL REPAIR INCLUDING REMOVAL AND REPLACEMENT OF EXISTING ROOFING SYSTEM AS PER DOB VIOLATION# 061819CCE0112G01.
B00185412-I1
08/07/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/17/2019
Violation issued (ECB, closed)
Construction
06/27/2019
Violation issued (ECB, closed)
Construction
06/27/2019
Violation issued (ECB, closed)
Construction
05/08/2019
Violation issued (ECB, closed)
Construction
11/07/2014
Violation issued (HPD, closed)
B
11/07/2014
Violation issued (HPD, closed)
B
11/07/2014
Violation issued (HPD, closed)
B
03/11/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/11/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/23/2003
Violation issued (ECB, closed)
Construction
10/27/2003
Violation issued (ECB, closed)
Construction
10/02/2003
Violation issued (ECB, closed)
Construction
10/02/2003
Violation issued (ECB, closed)
Construction
06/25/2003
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSupported ScaffoldPermit IssuedXINOS CONSTRUCTION CORP07/07/2022
DOB NOWSupported ScaffoldPermit IssuedXINOS CONSTRUCTION CORP03/31/2022
DOB NOWSupported ScaffoldPermit IssuedXINOS CONSTRUCTION CORP02/14/2020
DOB NOWSupported ScaffoldPermit IssuedXINOS CONSTRUCTION CORP08/27/2019
BISOTISSUEDXINOS CONSTRUCTION CORP03/08/2021
BISOTISSUEDXINOS CONSTRUCTION CORP10/28/2020
BISOTISSUEDXINOS CONSTRUCTION CORP03/04/2019
BISOTISSUEDXINOS CONSTRUCTION CORP08/24/2018
BIS—ISSUEDDYNAMIC TECH CONCEPTS & DESIGNS01/31/2006
BISEQISSUEDDISTINCTIVE WINDOW TREATMENT01/31/2006
BISEQISSUEDDISTINCTIVE WINDOW TREATMENT01/03/2006
BISPLISSUEDFLINT MECHANICAL CORP06/21/2005
BISEQISSUEDDISTINCTIVE WINDOW TREATMENT06/07/2005
BIS—ISSUEDDYNAMIC TECH CONCEPTS & DESIGNS03/30/2005
BISPLISSUEDG.A PLBG,HTG,SPR INC11/25/2003
BISEQISSUEDDISTINCTIVE WINDOW TREATMENT10/16/2003
BIS—ISSUEDDISTINCTIVE WINDOW TREATMENT07/01/2003
1 project · most recent 09/13/2019
Scaffold
FiledStatusContractorScope
09/13/2019Permit IssuedXINOS CONSTRUCTION CORPScaffold
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
06/01/2023Pass-Final CND-Occupancy InspectionPassView ↗
08/17/2022Pass-Final CND-Occupancy InspectionPassView ↗
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Supported Scaffold2
09/02/2026B00185412-I1Request digital key ↗
08/15/2026B00185412-P1Request digital key ↗
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION5
06/22/2020321767548Open ↗
06/16/2020321767548Open ↗
06/05/2020321767548Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION4
10/29/2020321767548Open ↗
10/26/2020321767548Open ↗
10/06/2020321767548Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications4
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
06/05/2018321767548Open ↗
06/05/2018321767548Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00185412-I1Open ↗
08/13/2026B00185412-P1Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
06/05/2018321767548Open ↗
▸Environmental & Asbestos1
▸BISDEP FORM V5 - ASBESTOS VARIANCE1
08/27/2018321767548Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
06/18/2020321767548Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
06/05/2018321767548Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
06/18/2020321767548Open ↗
▸Approvals, Objections & Sign-offs3
▸BISLANDMARKS APPROVAL2
06/29/2018321767548Open ↗
06/05/2018321767548Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
06/18/2020321767548Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
06/05/2018321767548Open ↗
▸Filing & Intake Forms4
▸BISBOROUGH INTAKE FORM2
10/26/2020321767548Open ↗
10/06/2020321767548Open ↗
▸BISADDITIONAL INFORMATION1
06/18/2020321767548Open ↗
▸BISEFILING COVER SHEET1
06/05/2018321767548Open ↗