← Back
Miscellaneous two family
2327 EAST 16 STREET
💬 Discuss this project
1940Year Built
1Stories
B9Building Class
R4Zoning
1,827 sfGross Floor Area
2Units
Miscellaneous two family · 2,200 sf lot · 0.83 FAR built · Flood zone X500
Locations of Work
ArchitectureElectricalPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction6p · 1 filing · 20 docs
Floor 1Under Construction1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
T C DESIGN1009/13/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/27/2025$940K—Private party → Private party$514/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NIC 88 CORP404/09/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WELLDONE INSPECTIONS INCGeneral Contractor104/09/2026
CROSSFIELD PLBG.&HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NIC DESIGN INC9758404/09/2026
Building Lifecycle
All (40)Filed (4)Permit Issued (2)Inspection (7)Special Inspection (27)
05/11/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/11/2026
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
05/07/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
04/10/2026
Special inspection requirement — HVAC-R and service water heating system controls
Eric Sun
04/10/2026
Special inspection requirement — Fire-Resistance Rated Construction
Eric Sun
04/10/2026
Special inspection requirement — HVAC-R and service water heating system controls
Eric Sun
04/10/2026
Special inspection requirement — HVAC-R and service water heating equipment
Eric Sun
04/10/2026
Special inspection requirement — Insulation placement and R values
Eric Sun
04/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Eric Sun
04/10/2026
Special inspection requirement — Interior lighting power
Eric Sun
04/10/2026
Special inspection requirement — Maintenance information
Eric Sun
04/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
04/10/2026
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
04/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Eric Sun
04/10/2026
Special inspection requirement — HVAC-R and service water heating equipment
Eric Sun
04/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
04/10/2026
Special inspection requirement — Mechanical Systems
Eric Sun
04/10/2026
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
04/10/2026
Special inspection requirement — Final
Eric Sun
04/09/2026
Filed — Alteration
INTERIOR RENOVATION OF 1ST AND 2ND FLOOR OF EXISTING 2 STORY BUILDING. DEMOLITION AND CONSTRUCTION WORK AS PER PLAN. INSTALL NEW HVAC, PARTITION, FLOORING, CEILING AND PAINTING THROUGHOUT. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01323558-P2
04/09/2026
Filed — Alteration
INTERIOR RENOVATION OF 1ST AND 2ND FLOOR OF EXISTING 2 STORY BUILDING. DEMOLITION AND CONSTRUCTION WORK AS PER PLAN. INSTALL NEW HVAC, PARTITION, FLOORING, CEILING AND PAINTING THROUGHOUT. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01323558-P1
04/08/2026
Special inspection requirement — Mechanical Systems
Eric Sun
04/08/2026
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
04/08/2026
Special inspection requirement — Final
Eric Sun
04/08/2026
Special inspection requirement — Fire-Resistance Rated Construction
Eric Sun
04/08/2026
Special inspection requirement — HVAC-R and service water heating system controls
Eric Sun
04/08/2026
Special inspection requirement — HVAC-R and service water heating equipment
Eric Sun
04/08/2026
Special inspection requirement — Insulation placement and R values
Eric Sun
04/08/2026
Special inspection requirement — Interior lighting power
Eric Sun
04/08/2026
Special inspection requirement — Maintenance information
Eric Sun
04/08/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Eric Sun
04/08/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
01/22/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/22/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/22/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/19/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/05/2025
Permit issued — Plumbing
B01323558-S1-PL
12/03/2025
Filed — Alteration
INTERIOR RENOVATION OF 1ST AND 2ND FLOOR OF EXISTING 2 STORY BUILDING. DEMOLITION AND CONSTRUCTION WORK AS PER PLAN. INSTALL NEW HVAC, PARTITION, FLOORING, CEILING AND PAINTING THROUGHOUT. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01323558-S1
11/25/2025
Permit issued — General Construction
B01323558-I1-GC-CX
11/24/2025
Filed — Alteration
INTERIOR RENOVATION OF 1ST AND 2ND FLOOR OF EXISTING 2 STORY BUILDING. DEMOLITION AND CONSTRUCTION WORK AS PER PLAN. INSTALL NEW HVAC, PARTITION, FLOORING, CEILING AND PAINTING THROUGHOUT. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01323558-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCROSSFIELD PLBG.&HTG12/05/2025
DOB NOWGeneral ConstructionPermit IssuedWELLDONE INSPECTIONS INC11/25/2025
1 project · most recent 04/09/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
04/09/2026Permit IssuedWELLDONE INSPECTIONS INCAir Conditioning Systems
Cooling
Mitsubishi Electric MUZ-GL18NA-U1 21,600 BTU · Condensing Unit ×3
MUZ-GL09NA 10,900 BTU · Condensing Unit ×1
MXZ-3C24NA 25,000 BTU · Condensing Unit ×1
1 project · most recent 04/09/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/09/2026Signed-offCROSSFIELD PLBG.&HTGGas, Water/Sanitary
2 projects · most recent 03/26/2026
General Wiring
FiledStatusContractorScope
03/26/2026Permit IssuedJ Y ELECTRIC INC2 meters, 2 new_meters
11/07/2025Permit IssuedJ Y ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
05/11/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/11/2026Certified Sprinkler - SP - RoughingCertifiedView ↗
05/07/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/22/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/22/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/22/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/19/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 27
DateRequirementInspectorRole
04/10/2026HVAC-R and service water heating system controlsEric Sunenergy_progress
04/10/2026Fire-Resistance Rated ConstructionEric Sunprogress
04/10/2026HVAC-R and service water heating system controlsEric Sunenergy_progress
04/10/2026HVAC-R and service water heating equipmentEric Sunenergy_progress
04/10/2026Insulation placement and R valuesEric Sunenergy_progress
04/10/2026HVAC-R and service water piping design and insulationEric Sunenergy_progress
04/10/2026Interior lighting powerEric Sunenergy_progress
04/10/2026Maintenance informationEric Sunenergy_progress
04/10/2026Fire-Resistant Penetrations and JointsEric Sunspecial
04/10/2026Energy Code Compliance InspectionsEric Sunprogress
04/10/2026HVAC-R and service water piping design and insulationEric Sunenergy_progress
04/10/2026HVAC-R and service water heating equipmentEric Sunenergy_progress
04/10/2026Fire-Resistant Penetrations and JointsEric Sunspecial
04/10/2026Mechanical SystemsEric Sunspecial
04/10/2026Energy Code Compliance InspectionsEric Sunprogress
04/10/2026FinalEric Sunprogress
04/08/2026Mechanical SystemsEric Sunspecial
04/08/2026Energy Code Compliance InspectionsEric Sunprogress
04/08/2026FinalEric Sunprogress
04/08/2026Fire-Resistance Rated ConstructionEric Sunprogress
04/08/2026HVAC-R and service water heating system controlsEric Sunenergy_progress
04/08/2026HVAC-R and service water heating equipmentEric Sunenergy_progress
04/08/2026Insulation placement and R valuesEric Sunenergy_progress
04/08/2026Interior lighting powerEric Sunenergy_progress
04/08/2026Maintenance informationEric Sunenergy_progress
Latest 25 of 27.
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/19/2026B01323558-S1Request digital key ↗
08/19/2026B01323558-I1Request digital key ↗
08/19/2026B01323558-P2Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications13
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B01323558-I1Open ↗
09/01/2026B01323558-I1Open ↗
08/27/2026B01323558-S1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/19/2026B01323558-S1Open ↗
08/19/2026B01323558-I1Open ↗
08/19/2026B01323558-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026B01323558-I1Open ↗
08/27/2026B01323558-S1Open ↗
08/24/2026B01323558-P2Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/19/2026B01323558-S1Open ↗
08/19/2026B01323558-I1Open ↗
08/19/2026B01323558-P1Open ↗
Showing 3 of 4 on file for this type