← Back
One story retail building
2334 RALPH AVENUE
BROOKLYN · BIN 3220531
💬 Discuss this project
1958Year Built
1Stories
K1Building Class
R3-2Zoning
5,300 sfGross Floor Area
3Units
3 Open Violations 2 unresolved · 1 paperwork only ▸FDNY Report ↗
One story retail building · Owner of record: JAMAP REALTY INC · 11,178 sf lot · 0.47 FAR built · Flood zone X500
Locations of Work
MechanicalPlumbing
Roof2p · 2 filings · 8 docs
1 job · most recent 11/02/2022
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
11/02/2022Permit IssuedJACK PICCINNI INCAir Conditioning Systems, Heating Systems
Cooling
Rheem RKKN-B073CL13E 70,000 BTU · Rooftop Unit ×3
Heating
Rheem RKKN-B073CL13E 135,000 BTU · Rooftop Unit ×3
1 job · most recent 11/02/2022
Gas
FiledStatusContractorScope
11/02/2022Permit IssuedP.R. PLUMBING & HTG INCGas
Building Lifecycle
All (16)Filed (2)Permit Issued (2)Violation (4)Special Inspection (8)
12/08/2022
Permit issued — Plumbing
B08017468-I1-PL
11/16/2022
Permit issued — Mechanical Systems
B08017044-I1-MS
11/02/2022
Filed — Alteration
REPLACE ROOFTOP HVAC UNITS.
B08017044-I1
11/02/2022
Filed — Alteration
GAS CONNECTION FOR REPLACEMENT HVAC UNITS.
B08017468-I1
10/07/2022
Special inspection requirement — Energy Code Compliance Inspections
LOUIS ARENA
10/07/2022
Special inspection requirement — Energy Code Compliance Inspections
LOUIS ARENA
10/07/2022
Special inspection requirement — Maintenance information
LOUIS ARENA
10/07/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
LOUIS ARENA
10/07/2022
Special inspection requirement — HVAC-R and service water heating system controls
LOUIS ARENA
10/07/2022
Special inspection requirement — HVAC-R and service water heating equipment
LOUIS ARENA
10/06/2022
Special inspection requirement — Final
LOUIS ARENA
10/06/2022
Special inspection requirement — Mechanical Systems
LOUIS ARENA
01/24/2001
Violation issued (ECB, closed)
Construction
01/22/2001
Violation issued (DOB, open)
VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
01/22/2001
Violation issued (ECB, open)
Construction
01/16/2001
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OWNER OF 2334 RALPH AVE103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW YORK ENGINEERING ASSOC., P.C.211/02/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEW YORK ENGINEERING ASSOCIATES P C203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JACK PICCINNI INCGeneral Contractor107/08/2026
CAM ENERGY HTG&MECH CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW YORK ENGINEERING ASSO851111/02/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedCAM ENERGY HTG&MECH CORP12/08/2022
DOB NOWMechanical SystemsPermit IssuedJACK PICCINNI INC11/16/2022
BISOTISSUEDMIDWOOD SIGN & DESIGN INC09/18/1998
BIS—ISSUEDMIDWOOD SIGN & DESIGN INC09/18/1998
BIS—ISSUEDMIDWOOD SIGN & DESIGN INC09/18/1998
BISPLISSUEDJ.JEKOWSKY & SON INC06/29/1998
BISEQISSUEDJACK PICCINNI INC06/17/1998
BISOTISSUEDBERGEN FUEL OIL CO.03/31/1993
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
10/07/2022Energy Code Compliance InspectionsLOUIS ARENAprogress
10/07/2022Energy Code Compliance InspectionsLOUIS ARENAprogress
10/07/2022Maintenance informationLOUIS ARENAenergy_progress
10/07/2022HVAC-R and service water piping design and insulationLOUIS ARENAenergy_progress
10/07/2022HVAC-R and service water heating system controlsLOUIS ARENAenergy_progress
10/07/2022HVAC-R and service water heating equipmentLOUIS ARENAenergy_progress
10/06/2022FinalLOUIS ARENAprogress
10/06/2022Mechanical SystemsLOUIS ARENAspecial
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/28/2026B08017468-I1Request digital key ↗
08/28/2026B08017044-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
09/06/2026B08017044-I1Open ↗
09/06/2026B08017044-I1Open ↗
08/27/2026B08017468-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B08017044-I1Open ↗
08/13/2026B08017468-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/06/2026B08017044-I1Open ↗