← Back
Factory, light manufacturing
2338 MCDONALD AVENUE
BROOKLYN · BIN 3193435
💬 Discuss this project
1958Year Built
1Stories
F5Building Class
C8-1Zoning
9,344 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Factory, light manufacturing · Owner of record: 2338 MCDONALD AVE LLC · 9,360 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingGeneral
Roof13p · 4 filings · 20 docs
Floor 191p · 1 filing · 10 docs
Floor 18
Floor 17
Floor 16
Floor 15
Floor 14
Floor 13
Floor 12
Floor 11
Floor 10
Floor 9
Floor 8
Floor 7
Floor 6
Floor 5
Floor 4
Floor 3
Floor 2
Floor 13p · 1 filing · 7 docs
1 job · most recent 10/07/2022
Air Conditioning Systems Associated Ducts and Piping Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/07/2022——Air Conditioning Systems, Associated Ducts and Piping, Heating Systems, Ventilation Systems
Cooling
Rheem RGECZT072ACT12BAA 6 tons · Rooftop Unit ×15
RGEDZS090AC 8 tons · Furnace ×5
RGEDZS120AC 10 tons ×5
Mitsubishi Electric PUY-A12NKA7 12,000 CFM · Split System ×10
PUY-A12NKA7/CU-1-1 12,000 BTU · Split System ×10
Heating
Tpi F1F5103N 400 CFM · Electric Heater ×20
F3483 425 CFM · Electric Heater ×10
Modine PTC85 85,000 BTU · Unit Heater ×10
Berner IDC12-3108G 4,536 CFM · Air Curtain ×5
Ventilation
Loren Cook 180KSP-B 7,530 CFM · Makeup Air ×15
Renewaire HE1.5JRTV-D35SS 800 CFM · Erv ×5
Ducts & Piping
Loren Cook CUE-080-VG 300 CFM · Exhaust Fan ×20
165VX150 450 CFM · Kitchen Exhaust ×10
CUE-100HP-VG 360 CFM ×10
180V17D 4,950 CFM · Kitchen Exhaust ×5
195V17D 5,100 CFM · Kitchen Exhaust ×5
245V11D 7,925 CFM · Kitchen Exhaust ×5
__Junk__ CUBE-100HP-5 600 CFM · Kitchen Exhaust ×5
1 job · most recent 09/26/2022
FiledStatusContractorScope
09/26/2022——300 heads
1 job · most recent 05/18/2024
Gas Water/Sanitary
FiledStatusContractorScope
05/18/2024——Gas, Water/Sanitary
3 jobs · most recent 04/24/2025
FiledStatusContractorScope
04/24/2025CompleteBERGER QUALITY ELEC'L CON—
07/13/2022Permit IssuedACCURATE ELEC'L CORP.1 meters, 1 new_meters
07/13/2022Permit IssuedACCURATE ELEC'L CORP.2 meters, 1 new_meters
1 job · most recent 11/29/2021
Steel
FiledStatusContractorScope
11/29/2021——Steel
1 job · most recent 05/16/2025
FiledStatusContractorScope
05/16/2025Permit IssuedBROOKLYN SOLAR PARTNERS88 panels, 51.48 kw, 9,429.3 roof_area_sqft
Building Lifecycle
All (137)Filed (15)Permit Issued (5)Violation (8)Objection (79)Special Inspection (30)
10/09/2025
Violation issued (FDNY_ORDER, closed)
10/09/2025
Violation issued (FDNY_ORDER, closed)
10/09/2025
Violation issued (FDNY_ORDER, closed)
10/09/2025
Violation issued (FDNY_ORDER, closed)
10/09/2025
Violation issued (FDNY_ORDER, closed)
10/09/2025
Violation issued (FDNY_ORDER, closed)
10/09/2025
Violation issued (FDNY_ORDER, closed)
10/09/2025
Violation issued (FDNY_ORDER, closed)
05/21/2025
Permit issued — Solar
B01223000-I1-SL
05/16/2025
Filed — Alteration
INSTALLATION OV PV SYSTEM ON EXISTING ROOF TOP. NO CHANGES TO THE USE EGRESS OR OCCUPANCY.
B01223000-I1
05/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
James Clancy
05/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
James Clancy
05/08/2025
Special inspection requirement — Air barrier - visual inspection
James Clancy
05/08/2025
Special inspection requirement — Energy Code Compliance Inspections
James Clancy
05/08/2025
Special inspection requirement — Final
James Clancy
05/21/2024
Special inspection requirement — HVAC-R and service water heating equipment
JAN PEREZ
05/21/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Withdrawn
05/21/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
JAN PEREZ
05/21/2024
Special inspection requirement — Maintenance information
JAN PEREZ
05/21/2024
Special inspection requirement — HVAC-R and service water heating system controls
JAN PEREZ
05/21/2024
Special inspection requirement — Energy Code Compliance Inspections
JAN PEREZ
05/18/2024
Filed — Alteration
INSTALL PLUMBING FIXTURES IN CONJUNCTION WITH JOB#B00609387 & B00502499
B00609436-P4
12/26/2023
Permit issued — General Construction
B00609387-I1-GC
07/26/2023
Objection resolved — Addressed
07/26/2023
Objection resolved — Addressed
07/25/2023
Objection raised — Scope
07/25/2023
Objection raised — Scope
07/22/2023
Filed — Alteration
INSTALL PLUMBING FIXTURES IN CONJUNCTION WITH JOB#B00609387 & B00502499
B00609436-P3
07/19/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
JAN PEREZ
07/19/2023
Special inspection requirement — Energy Code Compliance Inspections
JAN PEREZ
07/19/2023
Special inspection requirement — HVAC-R and service water heating equipment
JAN PEREZ
07/19/2023
Special inspection requirement — HVAC-R and service water heating system controls
JAN PEREZ
07/19/2023
Special inspection requirement — Maintenance information
JAN PEREZ
07/19/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
JAN PEREZ
01/19/2023
Permit issued — General Construction
B00609387-I1-GC
01/11/2023
Objection raised — Scope
01/05/2023
Filed — Alteration
INSTALL KITCHEN EQUIPMENT AS PER PLANS. EGRESS OR OCCUPANCY (INCLUDE OT WORK TYPE) FILED UNDER ALT-1 #B00502499. NO CHANGE EXISTING BUILDING HEIGHT; NO IN CREASE FLOOR AREA.
B00609387-P1
12/13/2022
Objection resolved — Addressed
12/13/2022
Objection resolved — Addressed
12/13/2022
Objection resolved — Addressed
12/13/2022
Objection resolved — Addressed
12/07/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
12/07/2022
Special inspection requirement — Final
12/07/2022
Special inspection requirement — Energy Code Compliance Inspections
12/07/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
12/07/2022
Special inspection requirement — Mechanical Systems
12/07/2022
Special inspection requirement — Shutoff dampers
12/07/2022
Special inspection requirement — HVAC-R and service water heating system controls
12/07/2022
Special inspection requirement — Maintenance information
12/07/2022
Special inspection requirement — HVAC-R and service water heating equipment
11/30/2022
Objection raised — Other
11/30/2022
Objection raised — Inspections
11/30/2022
Objection raised — Mechanical
11/30/2022
Objection raised — Admin
11/23/2022
Objection resolved — Addressed
11/16/2022
Filed — Alteration
INSTALL PLUMBING FIXTURES IN CONJUNCTION WITH JOB#B00609387 & B00502499
B00609436-P2
10/17/2022
Objection raised — Scope
10/14/2022
Objection resolved — Addressed
10/14/2022
Objection resolved — Addressed
10/14/2022
Objection resolved — Addressed
Latest 60 of 137 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NATE3607/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/11/2020$3.5M—— → —$375/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JAMES A CLANCY105/16/2025
ARC CONSULTING ENGINEERS1305/18/2024
RAS PE CONSULTING ENGINEERS111/29/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AMERILAND BROOK LLC1203/21/2026
ARC DESIGN AND CONSULTING LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ELITE GC NY INCGeneral Contractor1007/08/2026
BROOKLYN SOLAR PARTNERSGeneral Contractor303/21/2026
PAR PLUMBING CO., INCPlumbing303/22/2026
J. CAIAZZO PLBG & HTG CORGeneral Contractor203/22/2026
DPH PLUMBING & HTG CORPPlumbing203/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JAMES A CLANCY9176105/16/2025
ARC CONSULTING ENGINEERS,4083805/18/2024
AMERILAND BROOK LLC1506209/26/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedBROOKLYN SOLAR PARTNERS05/21/2025
DOB NOWGeneral ConstructionPermit IssuedELITE GC NY INC12/26/2023
DOB NOWGeneral ConstructionPermit IssuedELITE GC NY INC01/19/2023
DOB NOWGeneral ConstructionPermit IssuedELITE GC NY INC05/16/2022
DOB NOWGeneral ConstructionPermit IssuedELITE GC NY INC04/06/2022
BISMHISSUEDM & D CONSTRUCTION CO01/30/2003
▾Special Inspection Requirements (DOB NOW) — 65
DateRequirementInspectorRole
05/08/2025Structural Stability – Alterations of existing buildingsJames Clancyspecial
05/08/2025Fire-Resistant Penetrations and JointsJames Clancyspecial
05/08/2025Air barrier - visual inspectionJames Clancyenergy_progress
05/08/2025FinalJames Clancyprogress
05/08/2025Energy Code Compliance InspectionsJames Clancyprogress
05/21/2024HVAC-R and service water heating equipmentJAN PEREZenergy_progress
05/21/2024Energy Code Compliance InspectionsJAN PEREZprogress
05/21/2024Fire-Resistant Penetrations and JointsWithdrawnspecial
05/21/2024Maintenance informationJAN PEREZenergy_progress
05/21/2024HVAC-R and service water heating system controlsJAN PEREZenergy_progress
05/21/2024HVAC-R and service water piping design and insulationJAN PEREZenergy_progress
07/19/2023Energy Code Compliance InspectionsJAN PEREZprogress
07/19/2023Fire-Resistant Penetrations and JointsJAN PEREZspecial
07/19/2023HVAC-R and service water heating equipmentJAN PEREZenergy_progress
07/19/2023Maintenance informationJAN PEREZenergy_progress
07/19/2023HVAC-R and service water heating system controlsJAN PEREZenergy_progress
07/19/2023HVAC-R and service water piping design and insulationJAN PEREZenergy_progress
12/07/2022HVAC-R and service water heating system controls—energy_progress
12/07/2022Shutoff dampers—energy_progress
12/07/2022Final—progress
12/07/2022Energy Code Compliance Inspections—progress
12/07/2022Fire-Resistant Penetrations and Joints—special
12/07/2022Mechanical Systems—special
12/07/2022HVAC-R and service water piping design and insulation—energy_progress
12/07/2022HVAC-R and service water heating equipment—energy_progress
Latest 25 of 65.
▾Documents — 73 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch17
08/31/2026B00609436-P4Request digital key ↗
08/31/2026B00609436-P1Request digital key ↗
08/31/2026B00609436-P2Request digital key ↗
Showing 3 of 17 on file for this type
▸Seals & Professional Certifications48
▸DOB NOWProgress Inspector Seal & Signature20
09/17/2026B00609436-P3Open ↗
09/17/2026B00609436-P3Open ↗
09/02/2026B00609395-P1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature17
08/31/2026B00609436-I1Open ↗
08/31/2026B00609436-P1Open ↗
08/31/2026B00609436-P2Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
09/17/2026B00609436-P3Open ↗
09/02/2026B00609395-P1Open ↗
08/29/2026B01223000-I1Open ↗
Showing 3 of 11 on file for this type
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/29/2026B00609440-I1Open ↗
08/15/2026B00502499-I1Open ↗
08/14/2026B00502499-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWACP5/20/21 or V51
08/15/2026B00502499-I1Open ↗