← Back
Three families
2348 61 STREET
BROOKLYN · BIN 3172337
💬 Discuss this project
1930Year Built
2Stories
C0Building Class
R4-1Zoning
2,800 sfGross Floor Area
3Units
Rent Stabilized7 Open Violations ▸FDNY Report ↗
Three families · Owner of record: 2348 REALTY LLC · 2,500 sf lot · 1.12 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar1p · 1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
2348 REALTY LLC103/22/2026
GENESIS NYC CONSTRUCTION403/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/13/2025$1.6M—— → —$589/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
M-CON ENGINEERING, PC807/15/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JRK CREATIVE1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GENESIS NYC CONSTRUCTIONGeneral Contractor603/21/2026
CONTROL PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M-CON ENGINEERING7341607/15/2025
Building Lifecycle
All (57)Filed (8)Permit Issued (3)Signed Off (3)Violation (13)Inspection (7)Special Inspection (23)
05/01/2026
Violation issued (HPD, open)
A
11/18/2025
Violation issued (HPD, open)
I
10/03/2025
Signed off — Alteration
FILING THIS APPLICATION TO INSTALL PLUMBING FIXTURES ON CELLAR,1ST FL,2ND FL FOR EXIST.THREE FAMILY DWELLING UNITS.CONSTRUCTION WORK FILING SEPARATE APPLICATION,NO CHANGE TO USE,EGRESS OR OCCUPANCY
B01184144-I1
09/18/2025
Signed off — Alteration
INTERIOR RENOVATION FOR EXISTING 3 FAMILY DWELLING UNIT,ON CELLAR,1ST FL,2ND FL,NEW PARTITION WALL AND PLUMBING WORK FILING SEPARATE APPLICATION ,NO CHANGE TO USE,EGRESS OR OCCUPANCY
B01183773-I1
09/03/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/08/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/28/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/25/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/16/2025
Signed off — Alteration
INSTALL 8' HEIGHT TEMPORARY CONSTRUCTION FENCE AS PER PLAN.
B01209034-I1
07/16/2025
Special inspection requirement — Lighting in dwelling units
Michelle Contri
07/16/2025
Special inspection requirement — Final
Michelle Contri
07/16/2025
Special inspection requirement — Energy Code Compliance Inspections
Michelle Contri
07/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Michelle Contri
07/16/2025
Special inspection requirement — Insulation placement and R values
Michelle Contri
07/16/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Michelle Contri
07/15/2025
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING 3 FAMILY DWELLING UNIT,ON CELLAR,1ST FL,2ND FL,NEW PARTITION WALL AND PLUMBING WORK FILING SEPARATE APPLICATION ,NO CHANGE TO USE,EGRESS OR OCCUPANCY
B01183773-P3
07/09/2025
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING 3 FAMILY DWELLING UNIT,ON CELLAR,1ST FL,2ND FL,NEW PARTITION WALL AND PLUMBING WORK FILING SEPARATE APPLICATION ,NO CHANGE TO USE,EGRESS OR OCCUPANCY
B01183773-P2
07/09/2025
Filed — Alteration
FILING THIS APPLICATION TO INSTALL PLUMBING FIXTURES ON CELLAR,1ST FL,2ND FL FOR EXIST.THREE FAMILY DWELLING UNITS.CONSTRUCTION WORK FILING SEPARATE APPLICATION,NO CHANGE TO USE,EGRESS OR OCCUPANCY
B01184144-P1
07/08/2025
Special inspection requirement — Lighting in dwelling units
Michelle Contri
07/08/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Michelle Contri
07/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Michelle Contri
07/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Michelle Contri
07/08/2025
Special inspection requirement — Energy Code Compliance Inspections
Michelle Contri
07/08/2025
Special inspection requirement — Final
Michelle Contri
07/08/2025
Special inspection requirement — Insulation placement and R values
Michelle Contri
07/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Michelle Contri
07/08/2025
Special inspection requirement — Energy Code Compliance Inspections
Michelle Contri
07/08/2025
Special inspection requirement — HVAC-R and service water heating system controls
Michelle Contri
07/08/2025
Special inspection requirement — HVAC-R and service water heating equipment
Michelle Contri
06/20/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/06/2025
Violation issued (HPD, open)
A
06/06/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/06/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/24/2025
Filed — Alteration
INSTALL 8' HEIGHT TEMPORARY CONSTRUCTION FENCE AS PER PLAN.
B01209034-P1
04/24/2025
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING 3 FAMILY DWELLING UNIT,ON CELLAR,1ST FL,2ND FL,NEW PARTITION WALL AND PLUMBING WORK FILING SEPARATE APPLICATION ,NO CHANGE TO USE,EGRESS OR OCCUPANCY
B01183773-P1
04/15/2025
Permit issued — Construction Fence
B01209034-I1-FN
04/15/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Michelle Contri
04/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Michelle Contri
04/15/2025
Special inspection requirement — Insulation placement and R values
Michelle Contri
04/15/2025
Special inspection requirement — Lighting in dwelling units
Michelle Contri
04/15/2025
Special inspection requirement — Final
Michelle Contri
04/15/2025
Special inspection requirement — Energy Code Compliance Inspections
Michelle Contri
04/10/2025
Filed — Alteration
INSTALL 8' HEIGHT TEMPORARY CONSTRUCTION FENCE AS PER PLAN.
B01209034-I1
04/04/2025
Violation issued (ECB, closed)
Construction
04/04/2025
Violation issued (ECB, closed)
Construction
04/04/2025
Violation issued (ECB, closed)
Construction
04/04/2025
Violation issued (ECB, closed)
Construction
03/25/2025
Permit issued — Plumbing
B01184144-I1-PL
03/20/2025
Filed — Alteration
FILING THIS APPLICATION TO INSTALL PLUMBING FIXTURES ON CELLAR,1ST FL,2ND FL FOR EXIST.THREE FAMILY DWELLING UNITS.CONSTRUCTION WORK FILING SEPARATE APPLICATION,NO CHANGE TO USE,EGRESS OR OCCUPANCY
B01184144-I1
02/27/2025
Permit issued — General Construction
B01183773-I1-GC-CX
02/24/2025
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING 3 FAMILY DWELLING UNIT,ON CELLAR,1ST FL,2ND FL,NEW PARTITION WALL AND PLUMBING WORK FILING SEPARATE APPLICATION ,NO CHANGE TO USE,EGRESS OR OCCUPANCY
B01183773-I1
04/08/2024
Violation issued (HPD, open)
A
11/17/2023
Violation issued (HPD, closed)
I
03/20/2023
Violation issued (HPD, open)
A
02/22/2022
Violation issued (HPD, open)
A
04/06/2021
Violation issued (HPD, open)
A
04/06/2021
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FenceSigned-offGENESIS NYC CONSTRUCTION04/15/2025
DOB NOWPlumbingSigned-offCONTROL PLBG & HTG INC03/25/2025
DOB NOWGeneral ConstructionSigned-offGENESIS NYC CONSTRUCTION02/27/2025
1 project · most recent 09/04/2025
General Wiring
FiledStatusContractorScope
09/04/2025CompleteFIRST STAR ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
09/03/2025Pass-Final General Construction Non-Directive 14PassView ↗
08/08/2025Fail-Final General Construction Non-Directive 14FailView ↗
07/28/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/25/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/20/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/06/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/06/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
07/16/2025Lighting in dwelling unitsMichelle Contrienergy_progress
07/16/2025FinalMichelle Contriprogress
07/16/2025Energy Code Compliance InspectionsMichelle Contriprogress
07/16/2025Fire-Resistant Penetrations and JointsMichelle Contrispecial
07/16/2025Insulation placement and R valuesMichelle Contrienergy_progress
07/16/2025Structural Stability – Alterations of existing buildingsMichelle Contrispecial
07/08/2025Lighting in dwelling unitsMichelle Contrienergy_progress
07/08/2025HVAC-R and service water piping design and insulationMichelle Contrienergy_progress
07/08/2025Fire-Resistant Penetrations and JointsMichelle Contrispecial
07/08/2025Structural Stability – Alterations of existing buildingsMichelle Contrispecial
07/08/2025Energy Code Compliance InspectionsMichelle Contriprogress
07/08/2025FinalMichelle Contriprogress
07/08/2025Insulation placement and R valuesMichelle Contrienergy_progress
07/08/2025Fire-Resistant Penetrations and JointsMichelle Contrispecial
07/08/2025Energy Code Compliance InspectionsMichelle Contriprogress
07/08/2025HVAC-R and service water heating system controlsMichelle Contrienergy_progress
07/08/2025HVAC-R and service water heating equipmentMichelle Contrienergy_progress
04/15/2025Structural Stability – Alterations of existing buildingsMichelle Contrispecial
04/15/2025Fire-Resistant Penetrations and JointsMichelle Contrispecial
04/15/2025Insulation placement and R valuesMichelle Contrienergy_progress
04/15/2025Lighting in dwelling unitsMichelle Contrienergy_progress
04/15/2025FinalMichelle Contriprogress
04/15/2025Energy Code Compliance InspectionsMichelle Contriprogress
▾Documents — 41 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/22/2026B01183773-P3Request digital key ↗
08/22/2026B01183773-P2Request digital key ↗
08/22/2026B01183773-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications30
▸DOB NOWProgress Inspector Seal & Signature16
09/02/2026B01184144-P1Open ↗
09/02/2026B01184144-P1Open ↗
09/02/2026B01184144-P1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/22/2026B01183773-P2Open ↗
08/22/2026B01183773-P1Open ↗
08/22/2026B01183773-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/02/2026B01184144-P1Open ↗
09/01/2026B01183773-P1Open ↗
09/01/2026B01183773-P1Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/22/2026B01183773-P2Open ↗
08/22/2026B01183773-I1Open ↗
08/22/2026B01183773-P3Open ↗
Showing 3 of 5 on file for this type