← Back
Two family brick
2348 WEST STREET
BROOKLYN · Gravesend (East)-Homecrest · BIN 3194518
💬 Discuss this project
1955Year Built
2Stories
B1Building Class
R4Zoning
2,182 sfGross Floor Area
2Units
Two family brick · 2,000 sf lot · 1.09 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralGeneral
Filed — no permit issued11p · 1 filing · 12 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MSM ENGINEERING SERVICES, PLLC209/16/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MISTER EXPEDITER203/21/2026
Building Lifecycle
All (27)Filed (2)Objection (12)Special Inspection (13)
10/17/2025
Objection resolved — Addressed
10/09/2025
Objection raised — Admin
09/30/2025
Objection resolved — Addressed
09/30/2025
Objection resolved — Addressed
09/19/2025
Objection resolved — Addressed
09/18/2025
Objection raised — Zoning
09/18/2025
Objection raised — Admin
09/16/2025
Filed — Alteration
HEREBY FILING FOR TEMPORARY CONSTRUCTION FENCE
B01251278-S1
09/10/2025
Objection resolved — Addressed
08/20/2025
Objection resolved — Addressed
08/19/2025
Objection raised — Zoning
08/19/2025
Objection raised — Energy
08/01/2025
Objection raised — Admin
07/22/2025
Filed — Alteration
HEREBY FILING FOR TEMPORARY CONSTRUCTION FENCE
B01251278-I1
07/04/2025
Special inspection requirement — Permanent certificate
07/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/04/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/04/2025
Special inspection requirement — Concrete - Cast-In-Place
07/04/2025
Special inspection requirement — Energy Code Compliance Inspections
07/04/2025
Special inspection requirement — Fire-Resistance Rated Construction
07/04/2025
Special inspection requirement — Fenestration areas
07/04/2025
Special inspection requirement — Air barrier - visual inspection
07/04/2025
Special inspection requirement — Fenestration air leakage
07/04/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
07/04/2025
Special inspection requirement — Insulation placement and R values
07/04/2025
Special inspection requirement — Metering
07/03/2025
Special inspection requirement — Final
Nothing on file for this building.
1 project · most recent 09/16/2025
Fence
FiledStatusContractorScope
09/16/2025——Fence
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
07/04/2025Permanent certificate—energy_progress
07/04/2025Fire-Resistant Penetrations and Joints—special
07/04/2025Structural Stability – Alterations of existing buildings—special
07/04/2025Concrete - Cast-In-Place—special
07/04/2025Energy Code Compliance Inspections—progress
07/04/2025Fire-Resistance Rated Construction—progress
07/04/2025Fenestration areas—energy_progress
07/04/2025Air barrier - visual inspection—energy_progress
07/04/2025Fenestration air leakage—energy_progress
07/04/2025Fenestration and door U-factor and product ratings—energy_progress
07/04/2025Insulation placement and R values—energy_progress
07/04/2025Metering—energy_progress
07/03/2025Final—progress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026B01251278-I1Request digital key ↗
08/20/2026B01251278-S1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B01251278-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B01251278-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026B01251278-I1Open ↗
08/20/2026B01251278-S1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/20/2026B01251278-I1Open ↗
▸Other Documents3
▸DOB NOWPlot Diagram1
08/13/2026B01251278-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B01251278-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B01251278-I1Open ↗