← Back
One family attached or semi-detached
235-21 148 AVENUE
💬 Discuss this project
1965Year Built
2Stories
A5Building Class
R3-1Zoning
2,043 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · 2,725 sf lot · 0.75 FAR built · Flood zone AE
Locations of Work
ArchitectureStructuralElectricalPlumbingGeneralOther
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 2 filings · 16 docs
Floor 2Under Construction1p · 1 filing · 3 docs
Floor 1
Filed — no permit issued10p · 1 filing · 3 docs
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNRUN103/21/2026
NY State Solar LLC403/21/2026
ACA ASSOCIATES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRINITY SOLAR LLCGeneral Contractor303/21/2026
NYSS LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREEN RIVER ENVIRONMENTAL7841208/19/2025
PARKER AND WEST ENGINEERI5272106/20/2025
BITOPI CONSULTANTS LLC7036111/08/2024
Building Lifecycle
All (18)Filed (4)Permit Issued (2)Signed Off (1)Violation (1)Special Inspection (10)
11/25/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/28/2025
Signed off — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS
Q01259018-I1
08/20/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT MASONE
08/20/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT MASONE
08/20/2025
Special inspection requirement — Final
ROBERT MASONE
08/20/2025
Special inspection requirement — Energy Code Compliance Inspections
ROBERT MASONE
08/20/2025
Special inspection requirement — Air barrier - visual inspection
ROBERT MASONE
08/19/2025
Filed — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS
Q01259018-P1
08/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT MASONE
08/19/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT MASONE
08/19/2025
Special inspection requirement — Energy Code Compliance Inspections
ROBERT MASONE
08/19/2025
Special inspection requirement — Final
ROBERT MASONE
08/19/2025
Special inspection requirement — Air barrier - visual inspection
ROBERT MASONE
07/25/2025
Permit issued — Solar
Q01259018-I1-SL
07/21/2025
Filed — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS
Q01259018-I1
06/20/2025
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01243400-I1
11/20/2024
Permit issued — Solar
Q01138094-I1-SL
11/08/2024
Filed — Alteration
Q01138094-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offNYSS LLC07/25/2025
DOB NOWSolarPermit IssuedTRINITY SOLAR LLC11/20/2024
3 projects · most recent 07/21/2025
FiledStatusContractorScope
07/21/2025CompleteNY SOLAR ELECTRICAL LLC—
06/20/2025CancelledSUNRUN SOLAR ELECTL CORP—
10/31/2024CancelledREDLINE ELECTRIC INC—
1 project · most recent 06/20/2025
FiledStatusContractorScope
06/20/2025——8 panels, 3.24 kw, 168.18 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
08/20/2025Structural Stability – Alterations of existing buildingsROBERT MASONEspecial
08/20/2025Fire-Resistant Penetrations and JointsROBERT MASONEspecial
08/20/2025FinalROBERT MASONEprogress
08/20/2025Energy Code Compliance InspectionsROBERT MASONEprogress
08/20/2025Air barrier - visual inspectionROBERT MASONEenergy_progress
08/19/2025Fire-Resistant Penetrations and JointsROBERT MASONEspecial
08/19/2025Structural Stability – Alterations of existing buildingsROBERT MASONEspecial
08/19/2025Energy Code Compliance InspectionsROBERT MASONEprogress
08/19/2025FinalROBERT MASONEprogress
08/19/2025Air barrier - visual inspectionROBERT MASONEenergy_progress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026Q01138094-I1Request digital key ↗
08/19/2026Q01243400-I1Request digital key ↗
08/19/2026Q01259018-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/21/2026Q01138094-I1Open ↗
08/19/2026Q01243400-I1Open ↗
08/19/2026Q01259018-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/05/2026Q01259018-I1Open ↗
09/05/2026Q01259018-I1Open ↗
08/23/2026Q01259018-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/05/2026Q01259018-I1Open ↗
08/23/2026Q01259018-P1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/21/2026Q01138094-I1Open ↗
08/19/2026Q01243400-I1Open ↗
08/19/2026Q01259018-P1Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01259018-I1Open ↗