| Owner | Filings | Most Recent |
|---|---|---|
| 235 WEST 107TH STREET HOUSING DEV FUND C ORP | 31 | 07/08/2026 |
| 235 HOTEL | 6 | 03/21/2026 |
| CONSOLIDATED SCAFFOLDING INC. | 4 | 04/09/2026 |
| 235 W 107 ST LLC | 3 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/26/2021 | $12.6M | — | — → — | $596/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| OCV ARCHITECTS | 4 | 11/24/2025 |
| APPLIED HVAC ENGINEERING, PLLC | 8 | 11/14/2025 |
| PAUL G. JONES, P.E. | 5 | 12/13/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| SYNERGY BUILDING CONSULTANTS | 1 | 03/21/2026 |
| OCV ARCHITECTS | 12 | 03/21/2026 |
| CONSOLIDATED SCAFFOLD BRIDGE | 8 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| CONSOLIDATED SCAFFOLDING | General Contractor | 9 | 07/08/2026 |
| ARROW MECHANICAL CORP | General Contractor | 8 | 07/08/2026 |
| CONROCK CONSTRUCTION LLC | General Contractor | 6 | 07/08/2026 |
| GBL MECHANICAL INC | Plumbing | 3 | 07/08/2026 |
| AMERICAN STANDARD PLUMBING & | Fire Protection | 2 | 07/08/2026 |
| TRITECH ELECTL & DATA INC | Electrical | 2 | 03/22/2026 |
| DAMICO, HECTOR | Electrical | 1 | 03/21/2026 |
| MONERO, EUDY | Electrical | 1 | 03/21/2026 |
| LUNA NYC ELECTRIC CORP | Electrical | 1 | 03/22/2026 |
| BMT PLUMBING&HEATING LLC | Plumbing | 1 | 07/08/2026 |
| H JONAS & SON INC | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ACE STRUCTURAL ENGINEERIN | 496 | 12 | 11/24/2025 |
| RICHMOND TESTING LAB | 263 | 2 | 11/14/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | BMT PLUMBING&HEATING LLC | 11/14/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | ARROW MECHANICAL CORP | 10/01/2025 |
| DOB NOW | General Construction | Permit Issued | CONROCK CONSTRUCTION LLC | 09/18/2025 |
| DOB NOW | Supported Scaffold | Signed-off | CONSOLIDATED SCAFFOLDING | 06/03/2025 |
| DOB NOW | Sidewalk Shed | Signed-off | CONSOLIDATED SCAFFOLDING | 06/03/2025 |
| DOB NOW | General Construction | Permit Issued | CONROCK CONSTRUCTION LLC | 04/14/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | ARROW MECHANICAL CORP | 03/25/2025 |
| DOB NOW | Sprinklers | Permit Issued | AMERICAN STANDARD PLUMBIN | 01/21/2025 |
| DOB NOW | Construction Fence | Signed-off | CONSOLIDATED SCAFFOLDING | 12/13/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | ARROW MECHANICAL CORP | 07/09/2024 |
| DOB NOW | Supported Scaffold | Signed-off | CONSOLIDATED SCAFFOLDING | 07/02/2024 |
| DOB NOW | Sidewalk Shed | Signed-off | CONSOLIDATED SCAFFOLDING | 07/01/2024 |
| DOB NOW | Plumbing | Signed-off | LIQUID TECH PLBG&HTG,INC | 06/14/2024 |
| DOB NOW | General Construction | Permit Issued | CONROCK CONSTRUCTION LLC | 04/11/2024 |
| DOB NOW | Plumbing | Signed-off | LIQUID TECH PLBG&HTG,INC | 03/01/2024 |
| DOB NOW | Suspended Scaffold | Permit Issued | SASCO CONSTRUCTION SVC LL | 11/30/2023 |
| DOB NOW | Sprinklers | Permit Issued | AMERICAN STANDARD PLUMBIN | 10/16/2023 |
| DOB NOW | Mechanical Systems | Permit Issued | ARROW MECHANICAL CORP | 08/04/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | CONSOLIDATED SCAFFOLDING | 07/10/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | CONSOLIDATED SCAFFOLDING | 07/10/2023 |
| DOB NOW | Plumbing | Signed-off | LIQUID TECH PLBG&HTG,INC | 06/14/2023 |
| DOB NOW | Supported Scaffold | Signed-off | CONSOLIDATED SCAFFOLDING | 05/18/2023 |
| DOB NOW | Supported Scaffold | Signed-off | CONSOLIDATED SCAFFOLDING | 05/18/2023 |
| DOB NOW | General Construction | Permit Issued | CONROCK CONSTRUCTION LLC | 05/11/2023 |
| BIS | PL | ISSUED | BT'S PLUMBING AND HEATING | 10/24/2017 |
| BIS | SP | ISSUED | ASCO SPRINKLER CO.,INC | 10/21/2016 |
| BIS | PL | ISSUED | NCA PLUMBING&HEATING LLC | 09/28/2016 |
| BIS | BL | ISSUED | APPROVED OIL CO OF BKLYN | 04/21/2011 |
| BIS | OT | ISSUED | 235 HOTEL LLC | 04/28/2000 |
| BIS | FB | ISSUED | IRVING BAUER | 02/11/2000 |
| BIS | PL | ISSUED | BEST MECHANICAL SVCS INC | 05/13/1999 |
| BIS | OT | ISSUED | 235 HOTEL LLC | 04/21/1999 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 11/14/2025 | Permit Issued | ARROW MECHANICAL CORP | Air Conditioning Systems, Generators, Heating and Air Conditioning Systems, Heating Systems | Cooling Daikin FTX12AXVJU/RX12AXVJU 10,900 BTU · Ahu ×2 Lg LAN120HYV3/LAU120HYV3 13,785 BTU · Vrf Outdoor ×8 Heat / Cool Polarair IPTAC-HEN-09X 9,500 BTU · Heat Pump Outdoor ×155 Daikin FXAQ09PVJU 9,500 BTU · Vrf Indoor ×18 FXFQ24TVJU/FXDQ18MVJURXYMQ48PVJU 47,500 BTU · Vrf Indoor ×3 FBQ24PVJU/RZQ24TAVJUA 24,000 BTU · Ahu ×2 FBQ30PVJU/RZQ30TAVJUA 30,000 BTU · Split System ×2 FXAQ009PVJU 9,500 BTU · Vrf Indoor ×2 FXZQ05TAVJU 5,800 BTU · Vrf Indoor ×2 FXZQ09TAVJU 9,500 BTU · Vrf Indoor ×2 RXYQ96TTJU 92,000 BTU · Vrf Outdoor ×2 Tempmaster ZT049N08R2B2ACA3A2 53,100 BTU · Rooftop Unit ×3 ZT078N12R2B2ACA3A2 75,900 BTU · Rooftop Unit ×3 Greenheck G-140HP-VG 630 CFM · Exhaust Fan ×1 Lg ARNU093SJS4 9,600 BTU · Vrf Indoor ×42 ARNU183MIA4/ARNU048GSS4 19,100 BTU · Vrf Indoor ×4 ARUM096BTE5 96,000 BTU · Vrf Outdoor ×4 LAN090HYV3/LAU090HYV3 11,970 BTU · Heat Pump Outdoor ×4 LHN248HVI/LUU240HHV 29,500 BTU · Vrf Indoor ×4 LHN368HV/LUU369HV 41,400 BTU · Condensing Unit ×4 ARNU053TRC4 5,800 BTU · Vrf Indoor ×2 ARNU053TRD4 5,800 BTU · Vrf Indoor ×2 ARNU093TRC4 5,800 BTU · Vrf Indoor ×2 ARNU093TRD4 9,500 BTU · Vrf Indoor ×2 ARNU243TAA4 24,200 BTU · Vrf Indoor ×2 Heating Security Chimneys SSD SERIES 1 CFM · Boiler ×4 Stelpro ASK0501 60 CFM · Unit Heater ×108 AWF6008CT 6 kW · Unit Heater ×6 ASHU0583CTCHAR 5 kW · Exhaust Fan ×2 ASHU1583CTCHAR 15 kW · Exhaust Fan ×2 AWF4008T 3 kW · Unit Heater ×2 Ventilation Floaire FABI11DD-RM 750 CFM · Exhaust Fan ×10 DR50H 600 CFM · Exhaust Fan ×4 FABI13DD-RM 1,035 CFM · Exhaust Fan ×2 Generators Kholes 48RCLC 48 kW · Generator ×3 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/23/2025 | Permit Issued | AMERICAN STANDARD PLUMBIN | 567 heads |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/23/2025 | — | — | — |
| 10/23/2025 | Signed-off | GBL MECHANICAL GROUP INC | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/25/2025 | Permit Issued | TRITECH ELECTL & DATA INC | General Wiring |
| 09/16/2025 | Permit Issued | JAM ELECTRICAL CORP | — |
| 08/20/2025 | Complete | JAM ELECTRICAL CORP | — |
| 07/03/2023 | Permit Issued | LUNA NYC ELECTRIC CORP | General Wiring |
| 04/24/2023 | Complete | SOLAS ELECTRICAL CORP | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/16/2023 | Permit Issued | — | Suspended Scaffold (SC) |
| Date | Type | Result | Report |
|---|---|---|---|
| 11/21/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/19/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 10/28/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 04/12/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 04/12/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 03/05/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 12/04/2025 | Air barrier - visual inspection | ANTHONY UGBEBOR | energy_progress |
| 12/04/2025 | Exterior lighting power | ANTHONY UGBEBOR | energy_progress |
| 12/04/2025 | Lighting controls | ANTHONY UGBEBOR | energy_progress |
| 12/04/2025 | Mastic and Intumescent Fire-resistant Coatings | ANTHONY UGBEBOR | special |
| 12/04/2025 | Structural Stability – Alterations of existing buildings | ANTHONY UGBEBOR | special |
| 12/04/2025 | Fire-Resistant Penetrations and Joints | ANTHONY UGBEBOR | special |
| 12/04/2025 | Masonry | ANTHONY UGBEBOR | special |
| 12/04/2025 | Fenestration air leakage | ANTHONY UGBEBOR | energy_progress |
| 12/04/2025 | Electrical motors and elevators | ANTHONY UGBEBOR | energy_progress |
| 12/04/2025 | Fenestration and door U-factor and product ratings | ANTHONY UGBEBOR | energy_progress |
| 12/04/2025 | Insulation placement and R values | ANTHONY UGBEBOR | energy_progress |
| 12/04/2025 | Lighting in dwelling units | ANTHONY UGBEBOR | energy_progress |
| 12/04/2025 | Interior lighting power | ANTHONY UGBEBOR | energy_progress |
| 12/04/2025 | Sprayed fire-resistant materials | ANTHONY UGBEBOR | special |
| 12/04/2025 | Metering | ANTHONY UGBEBOR | energy_progress |
| 12/04/2025 | Energy Code Compliance Inspections | ANTHONY UGBEBOR | progress |
| 12/04/2025 | Fire-Resistance Rated Construction | ANTHONY UGBEBOR | progress |
| 12/04/2025 | Maintenance information | ANTHONY UGBEBOR | energy_progress |
| 11/12/2025 | HVAC-R and service water heating system controls | ANTHONY UGBEBOR | energy_progress |
| 11/12/2025 | Energy Code Compliance Inspections | ANTHONY UGBEBOR | progress |
| 11/12/2025 | Fire-Resistant Penetrations and Joints | ANTHONY UGBEBOR | special |
| 11/12/2025 | HVAC-R and service water heating equipment | ANTHONY UGBEBOR | energy_progress |
| 11/12/2025 | Maintenance information | ANTHONY UGBEBOR | energy_progress |
| 11/12/2025 | HVAC-R and service water piping design and insulation | ANTHONY UGBEBOR | energy_progress |
| 10/07/2025 | Fire-Resistant Penetrations and Joints | ANTHONY UGBEBOR | special |