← Back
Extended stay / suite - apartment-like amenities
Goddard. 235 W 107th Street. Stephan Russo Residence
235 WEST 107 STREET · Upper West Side-Manhattan Valley · BIN 1056651
💬 Discuss this project
1920Year Built
6Stories
HSBuilding Class
R8BZoning
21,144 sfGross Floor Area
95Units
Rent Stabilized7 Open Violations 1 unresolved · 6 paperwork only ▸
Extended stay / suite - apartment-like amenities · Owner of record: 235 WEST 107TH STREET HOUSING DEV FUND C ORP · 5,046 sf lot · 4.19 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneral
Roof66p · 3 filings · 20 docs
Floor 77p · 1 filing · 15 docs
Floor 674p · 4 filings · 20 docs
Floor 5103p · 5 filings · 20 docs
Floor 496p · 5 filings · 20 docs
Floor 396p · 5 filings · 20 docs
Floor 297p · 5 filings · 20 docs
Floor 1101p · 5 filings · 20 docs
Cellar101p · 4 filings · 20 docs
Site & exterior7p · 1 filing · 15 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
235 WEST 107TH STREET HOUSING DEV FUND C ORP3107/08/2026
235 HOTEL603/21/2026
CONSOLIDATED SCAFFOLDING INC.404/09/2026
235 W 107 ST LLC303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/26/2021$12.6M—— → —$596/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
OCV ARCHITECTS411/24/2025
APPLIED HVAC ENGINEERING, PLLC811/14/2025
PAUL G. JONES, P.E.512/13/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SYNERGY BUILDING CONSULTANTS103/21/2026
OCV ARCHITECTS1203/21/2026
CONSOLIDATED SCAFFOLD BRIDGE803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CONSOLIDATED SCAFFOLDINGGeneral Contractor907/08/2026
ARROW MECHANICAL CORPGeneral Contractor807/08/2026
CONROCK CONSTRUCTION LLCGeneral Contractor607/08/2026
GBL MECHANICAL INCPlumbing307/08/2026
AMERICAN STANDARD PLUMBING &Fire Protection207/08/2026
TRITECH ELECTL & DATA INCElectrical203/22/2026
DAMICO, HECTORElectrical103/21/2026
MONERO, EUDYElectrical103/21/2026
LUNA NYC ELECTRIC CORPElectrical103/22/2026
BMT PLUMBING&HEATING LLCPlumbing107/08/2026
H JONAS & SON INCElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ACE STRUCTURAL ENGINEERIN4961211/24/2025
RICHMOND TESTING LAB263211/14/2025
Building Lifecycle
All (142)Filed (18)Permit Issued (24)Signed Off (2)Violation (60)Inspection (6)Objection (2)Special Inspection (30)
06/05/2026
Violation issued (ECB, open)
Construction
06/05/2026
Violation issued (ECB, open)
Construction
04/05/2026
Violation issued (HPD, closed)
C
04/05/2026
Violation issued (HPD, closed)
B
04/05/2026
Violation issued (HPD, closed)
B
04/05/2026
Violation issued (HPD, closed)
A
03/05/2026
Violation issued (ECB, closed)
Elevators
03/05/2026
Violation issued (ECB, open)
Elevators
01/27/2026
Signed off — Alteration
INSTALLATION OF A HEAVY DUTY SIDEWALK SHED AND PIPE SCAFFOLD AS PER PLANS DURING GENERAL CONSTRUCTION WORK. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED & PIPE SCAFFOLD TO COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE OF 2022.
M00859134-S1
01/27/2026
Signed off — Alteration
INSTALLATION OF A HEAVY DUTY SIDEWALK SHED AND PIPE SCAFFOLD AS PER PLANS DURING GENERAL CONSTRUCTION WORK. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED & PIPE SCAFFOLD TO COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE OF 2022.
M00859134-I1
12/04/2025
Special inspection requirement — Fire-Resistance Rated Construction
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Energy Code Compliance Inspections
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Fenestration air leakage
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Interior lighting power
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Maintenance information
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Insulation placement and R values
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Sprayed fire-resistant materials
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Exterior lighting power
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Metering
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Lighting controls
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Electrical motors and elevators
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Air barrier - visual inspection
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Lighting in dwelling units
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY UGBEBOR
12/04/2025
Special inspection requirement — Masonry
ANTHONY UGBEBOR
12/03/2025
Objection resolved — Addressed
11/26/2025
Objection raised — Admin
11/24/2025
Filed — Alteration CO
EXTERIOR AND INTERIOR RENOVATION OF EXISTING BUILDING. REPLACEMENT OF WINDOWS AND DOORS, KITCHEN BATH AND LIGHTING FIXTURES, FINISHES, AND MINOR FACADE REPAIR WORK.
M00612442-P3
11/21/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/19/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/14/2025
Filed — Alteration
INSTALLATION OF VARIABLE REFRIGERANT FLOW HEAT PUMP, AND HIGH EFFICIENCY THRU THE WALL UNITS, FOR SPACE HTG/CLG. GAS FIRED ROOF TOP UNITS FOR VENTILATION OF COMMON AREAS, KITCHEN AND TOILET EXHAUST FANS, INTAKE AND DISCHARGE VENTS FOR GAS DHW BOILERS
M08019648-P3
11/14/2025
Permit issued — Plumbing
M08019756-I1-PL
11/12/2025
Special inspection requirement — Energy Code Compliance Inspections
ANTHONY UGBEBOR
11/12/2025
Special inspection requirement — HVAC-R and service water heating system controls
ANTHONY UGBEBOR
11/12/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
ANTHONY UGBEBOR
11/12/2025
Special inspection requirement — Maintenance information
ANTHONY UGBEBOR
11/12/2025
Special inspection requirement — HVAC-R and service water heating equipment
ANTHONY UGBEBOR
11/12/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY UGBEBOR
10/28/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/23/2025
Filed — Alteration
INSTALLATION OF WET AUTOMATIC SPRINKLER SYSTEM, PIPING AND EQUIPMENT.
M08020592-P2
10/23/2025
Filed — Alteration
INSTALLATION OF NEW 6" SANITARY & 6" STORM PIPES, INSTALLATION OF NEW PLUMBING FIXTURES, BLACK FLOW PREVENTER, DOMESTIC BOOSTER PUMPS, GAS PIPING FOR RTU, BOILERS AND STANDBY GENERATOR
M08019756-P1
10/07/2025
Special inspection requirement — HVAC-R and service water heating system controls
ANTHONY UGBEBOR
10/07/2025
Special inspection requirement — Lighting controls
ANTHONY UGBEBOR
10/07/2025
Special inspection requirement — Maintenance information
ANTHONY UGBEBOR
10/07/2025
Special inspection requirement — HVAC-R and service water heating equipment
ANTHONY UGBEBOR
10/07/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
ANTHONY UGBEBOR
10/07/2025
Special inspection requirement — Final
ANTHONY UGBEBOR
10/01/2025
Permit issued — Mechanical Systems
M08019648-I1-MS
09/18/2025
Permit issued — General Construction
M00612442-I1-GC
07/24/2025
Filed — Alteration CO
EXTERIOR AND INTERIOR RENOVATION OF EXISTING BUILDING. REPLACEMENT OF WINDOWS AND DOORS, KITCHEN BATH AND LIGHTING FIXTURES, FINISHES, AND MINOR FACADE REPAIR WORK.
M00612442-P2
06/04/2025
Violation issued (HPD, closed)
A
06/03/2025
Permit issued — Supported Scaffold
M00859134-I1-SF
06/03/2025
Permit issued — Sidewalk Shed
M00859134-I1-SH
04/26/2025
Violation issued (ECB, closed)
Unknown
04/26/2025
Violation issued (ECB, closed)
Construction
04/14/2025
Permit issued — General Construction
M00612442-I1-GC
03/25/2025
Permit issued — Mechanical Systems
M08019648-I1-MS
Latest 60 of 142 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offBMT PLUMBING&HEATING LLC11/14/2025
DOB NOWMechanical SystemsPermit IssuedARROW MECHANICAL CORP10/01/2025
DOB NOWGeneral ConstructionPermit IssuedCONROCK CONSTRUCTION LLC09/18/2025
DOB NOWSupported ScaffoldSigned-offCONSOLIDATED SCAFFOLDING06/03/2025
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING06/03/2025
DOB NOWGeneral ConstructionPermit IssuedCONROCK CONSTRUCTION LLC04/14/2025
DOB NOWMechanical SystemsPermit IssuedARROW MECHANICAL CORP03/25/2025
DOB NOWSprinklersPermit IssuedAMERICAN STANDARD PLUMBIN01/21/2025
DOB NOWConstruction FenceSigned-offCONSOLIDATED SCAFFOLDING12/13/2024
DOB NOWMechanical SystemsPermit IssuedARROW MECHANICAL CORP07/09/2024
DOB NOWSupported ScaffoldSigned-offCONSOLIDATED SCAFFOLDING07/02/2024
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING07/01/2024
DOB NOWPlumbingSigned-offLIQUID TECH PLBG&HTG,INC06/14/2024
DOB NOWGeneral ConstructionPermit IssuedCONROCK CONSTRUCTION LLC04/11/2024
DOB NOWPlumbingSigned-offLIQUID TECH PLBG&HTG,INC03/01/2024
DOB NOWSuspended ScaffoldPermit IssuedSASCO CONSTRUCTION SVC LL11/30/2023
DOB NOWSprinklersPermit IssuedAMERICAN STANDARD PLUMBIN10/16/2023
DOB NOWMechanical SystemsPermit IssuedARROW MECHANICAL CORP08/04/2023
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING07/10/2023
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING07/10/2023
DOB NOWPlumbingSigned-offLIQUID TECH PLBG&HTG,INC06/14/2023
DOB NOWSupported ScaffoldSigned-offCONSOLIDATED SCAFFOLDING05/18/2023
DOB NOWSupported ScaffoldSigned-offCONSOLIDATED SCAFFOLDING05/18/2023
DOB NOWGeneral ConstructionPermit IssuedCONROCK CONSTRUCTION LLC05/11/2023
BISPLISSUEDBT'S PLUMBING AND HEATING10/24/2017
BISSPISSUEDASCO SPRINKLER CO.,INC10/21/2016
BISPLISSUEDNCA PLUMBING&HEATING LLC09/28/2016
BISBLISSUEDAPPROVED OIL CO OF BKLYN04/21/2011
BISOTISSUED235 HOTEL LLC04/28/2000
BISFBISSUEDIRVING BAUER02/11/2000
BISPLISSUEDBEST MECHANICAL SVCS INC05/13/1999
BISOTISSUED235 HOTEL LLC04/21/1999
1 project · most recent 11/14/2025
Air Conditioning Systems Generators Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/14/2025Permit IssuedARROW MECHANICAL CORPAir Conditioning Systems, Generators, Heating and Air Conditioning Systems, Heating Systems
Cooling
Daikin FTX12AXVJU/RX12AXVJU 10,900 BTU · Ahu ×2
Lg LAN120HYV3/LAU120HYV3 13,785 BTU · Vrf Outdoor ×8
Heat / Cool
Polarair IPTAC-HEN-09X 9,500 BTU · Heat Pump Outdoor ×155
Daikin FXAQ09PVJU 9,500 BTU · Vrf Indoor ×18
FXFQ24TVJU/FXDQ18MVJURXYMQ48PVJU 47,500 BTU · Vrf Indoor ×3
FBQ24PVJU/RZQ24TAVJUA 24,000 BTU · Ahu ×2
FBQ30PVJU/RZQ30TAVJUA 30,000 BTU · Split System ×2
FXAQ009PVJU 9,500 BTU · Vrf Indoor ×2
FXZQ05TAVJU 5,800 BTU · Vrf Indoor ×2
FXZQ09TAVJU 9,500 BTU · Vrf Indoor ×2
RXYQ96TTJU 92,000 BTU · Vrf Outdoor ×2
Tempmaster ZT049N08R2B2ACA3A2 53,100 BTU · Rooftop Unit ×3
ZT078N12R2B2ACA3A2 75,900 BTU · Rooftop Unit ×3
Greenheck G-140HP-VG 630 CFM · Exhaust Fan ×1
Lg ARNU093SJS4 9,600 BTU · Vrf Indoor ×42
ARNU183MIA4/ARNU048GSS4 19,100 BTU · Vrf Indoor ×4
ARUM096BTE5 96,000 BTU · Vrf Outdoor ×4
LAN090HYV3/LAU090HYV3 11,970 BTU · Heat Pump Outdoor ×4
LHN248HVI/LUU240HHV 29,500 BTU · Vrf Indoor ×4
LHN368HV/LUU369HV 41,400 BTU · Condensing Unit ×4
ARNU053TRC4 5,800 BTU · Vrf Indoor ×2
ARNU053TRD4 5,800 BTU · Vrf Indoor ×2
ARNU093TRC4 5,800 BTU · Vrf Indoor ×2
ARNU093TRD4 9,500 BTU · Vrf Indoor ×2
ARNU243TAA4 24,200 BTU · Vrf Indoor ×2
Heating
Security Chimneys SSD SERIES 1 CFM · Boiler ×4
Stelpro ASK0501 60 CFM · Unit Heater ×108
AWF6008CT 6 kW · Unit Heater ×6
ASHU0583CTCHAR 5 kW · Exhaust Fan ×2
ASHU1583CTCHAR 15 kW · Exhaust Fan ×2
AWF4008T 3 kW · Unit Heater ×2
Ventilation
Greenheck G-140HP-VG 965 CFM · Exhaust Fan ×5
G-100HP-VG 367 CFM · Exhaust Fan ×2
Floaire FABI11DD-RM 750 CFM · Exhaust Fan ×10
DR50H 600 CFM · Exhaust Fan ×4
FABI13DD-RM 1,035 CFM · Exhaust Fan ×2
Generators
Kholes 48RCLC 48 kW · Generator ×3
1 project · most recent 10/23/2025
FiledStatusContractorScope
10/23/2025Permit IssuedAMERICAN STANDARD PLUMBIN567 heads
2 projects · most recent 10/23/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
10/23/2025———
10/23/2025Signed-offGBL MECHANICAL GROUP INCGas, Storm, Water/Sanitary
5 projects · most recent 11/25/2025
General Wiring
FiledStatusContractorScope
11/25/2025Permit IssuedTRITECH ELECTL & DATA INCGeneral Wiring
09/16/2025Permit IssuedJAM ELECTRICAL CORP—
08/20/2025CompleteJAM ELECTRICAL CORP—
07/03/2023Permit IssuedLUNA NYC ELECTRIC CORPGeneral Wiring
04/24/2023CompleteSOLAS ELECTRICAL CORP—
1 project · most recent 11/16/2023
Suspended Scaffold (SC)
FiledStatusContractorScope
11/16/2023Permit Issued—Suspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
11/21/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/19/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/28/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/12/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/12/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/05/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 77
DateRequirementInspectorRole
12/04/2025Air barrier - visual inspectionANTHONY UGBEBORenergy_progress
12/04/2025Exterior lighting powerANTHONY UGBEBORenergy_progress
12/04/2025Lighting controlsANTHONY UGBEBORenergy_progress
12/04/2025Mastic and Intumescent Fire-resistant CoatingsANTHONY UGBEBORspecial
12/04/2025Structural Stability – Alterations of existing buildingsANTHONY UGBEBORspecial
12/04/2025Fire-Resistant Penetrations and JointsANTHONY UGBEBORspecial
12/04/2025MasonryANTHONY UGBEBORspecial
12/04/2025Fenestration air leakageANTHONY UGBEBORenergy_progress
12/04/2025Electrical motors and elevatorsANTHONY UGBEBORenergy_progress
12/04/2025Fenestration and door U-factor and product ratingsANTHONY UGBEBORenergy_progress
12/04/2025Insulation placement and R valuesANTHONY UGBEBORenergy_progress
12/04/2025Lighting in dwelling unitsANTHONY UGBEBORenergy_progress
12/04/2025Interior lighting powerANTHONY UGBEBORenergy_progress
12/04/2025Sprayed fire-resistant materialsANTHONY UGBEBORspecial
12/04/2025MeteringANTHONY UGBEBORenergy_progress
12/04/2025Energy Code Compliance InspectionsANTHONY UGBEBORprogress
12/04/2025Fire-Resistance Rated ConstructionANTHONY UGBEBORprogress
12/04/2025Maintenance informationANTHONY UGBEBORenergy_progress
11/12/2025HVAC-R and service water heating system controlsANTHONY UGBEBORenergy_progress
11/12/2025Energy Code Compliance InspectionsANTHONY UGBEBORprogress
11/12/2025Fire-Resistant Penetrations and JointsANTHONY UGBEBORspecial
11/12/2025HVAC-R and service water heating equipmentANTHONY UGBEBORenergy_progress
11/12/2025Maintenance informationANTHONY UGBEBORenergy_progress
11/12/2025HVAC-R and service water piping design and insulationANTHONY UGBEBORenergy_progress
10/07/2025Fire-Resistant Penetrations and JointsANTHONY UGBEBORspecial
Latest 25 of 77.
▾Documents — 225 on file (BIS + DOB NOW)
▸Plans & Drawings18
▸DOB NOWPlans/Sketch18
08/31/2026M00612442-I1Request digital key ↗
08/31/2026M00612442-P3Request digital key ↗
08/31/2026M00612442-P2Request digital key ↗
Showing 3 of 18 on file for this type
▸Applications & Permits16
▸BISPLAN / WORK APPROVAL APPLICATION12
09/01/2017122849463Open ↗
08/18/2017122849463Open ↗
05/31/2017122849463Open ↗
Showing 3 of 12 on file for this type
▸BISWORK PERMIT APPLICATION4
10/25/2017122849463Open ↗
09/29/2016122849463Open ↗
04/25/2011120548372Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications114
▸DOB NOWProgress Inspector Seal & Signature60
09/01/2026M08019756-I1Open ↗
09/01/2026M08019756-I1Open ↗
09/01/2026M08019756-I1Open ↗
Showing 3 of 60 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature28
09/01/2026M08019756-I1Open ↗
08/28/2026M00612442-P1Open ↗
08/28/2026M00612442-P1Open ↗
Showing 3 of 28 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature17
08/31/2026M00612442-I1Open ↗
08/31/2026M00612442-P3Open ↗
08/31/2026M00612442-P2Open ↗
Showing 3 of 17 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
01/09/2017122849463Open ↗
08/05/2016122849463Open ↗
10/14/2015122362273Open ↗
Showing 3 of 8 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/05/2016122849463Open ↗
▸Trade Schedules & Equipment9
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE7
09/01/2017122849463Open ↗
08/18/2017122849463Open ↗
05/31/2017122849463Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE B - PLUMBING1
05/30/2012121063008Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
12/10/2010120548372Open ↗
▸Safety & Tenant Protection28
▸DOB NOWHPD-3: Single Room Occupancy Multiple Dwelling (SRO MD) Anti-Harassment Checklist17
08/20/2026M08019648-P1Open ↗
08/20/2026M08019648-I1Open ↗
08/13/2026M00612442-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWStreet Tree Checklist4
08/13/2026M00612442-P1Open ↗
08/13/2026M00612442-P2Open ↗
08/13/2026M00612442-P3Open ↗
Showing 3 of 4 on file for this type
▸BISSRO MD ANTI-HARASSMENT CHECKLIST3
08/05/2016122849463Open ↗
04/14/2015122362273Open ↗
06/15/2012121063008Open ↗
▸BISSTREET TREE CHECKLIST3
12/08/2016122849463Open ↗
04/14/2015122362273Open ↗
12/10/2010120548372Open ↗
▸BISHPD-1 - Anti-Harassment Area Checklist1
01/26/2011120548372Open ↗
▸Environmental & Asbestos9
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
07/24/2018122362273Open ↗
08/05/2016122849463Open ↗
08/05/2016122849463Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
08/31/2026M00612442-I1Open ↗
08/21/2026M08020592-I1Open ↗
08/21/2026M08019756-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
12/10/2010120548372Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
10/14/2015122362273Open ↗
07/07/2015120548372Open ↗
04/14/2015122362273Open ↗
▸BISTECHNICAL REPORT: ENERGY1
04/28/2011120548372Open ↗
▸Approvals, Objections & Sign-offs13
▸BISSCHEDULE A - OCCUPANCY / USE4
08/30/2016122362273Open ↗
10/14/2015122362273Open ↗
10/14/2015122362273Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP Variance (V5) letter4
08/13/2026M08019756-I1Open ↗
08/13/2026M08020592-I1Open ↗
08/13/2026M00612442-I1Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS2
05/04/2012121063008Open ↗
12/10/2010120548372Open ↗
▸BISSUPERSEDING LETTER1
10/25/2017122849463Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
07/07/2015120548372Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/07/2015120548372Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
08/05/2016122849463Open ↗
04/14/2015122362273Open ↗
05/30/2012121063008Open ↗
▸Filing & Intake Forms7
▸BISADDITIONAL INFORMATION3
09/01/2017122849463Open ↗
05/16/2017122849463Open ↗
03/02/2017122849463Open ↗
▸BISEFILING COVER SHEET3
08/05/2016122849463Open ↗
04/14/2015122362273Open ↗
12/10/2010120548372Open ↗
▸BISBOROUGH INTAKE FORM1
08/18/2017122849463Open ↗
▸Other Documents4
▸BISPLOT DIAGRAM1
04/14/2015122362273Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026M00963731-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026M00612442-I1Open ↗
▸DOB NOWCalculations1