← Back
Two family converted from one family
2350 EAST 1 STREET
BROOKLYN · Gravesend (East)-Homecrest · BIN 3194568
💬 Discuss this project
1925Year Built
2Stories
B3Building Class
R4Zoning
1,500 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family converted from one family · Owner of record: 2350 EAST 1ST STREET LLC · 2,000 sf lot · 0.75 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbingEquipment
Permit Issued — active, not yet Signed-off
Floor 2Under Construction66p · 1 filing · 20 docs
Floor 1Under Construction62p · 1 filing · 20 docs
CellarUnder Construction64p · 1 filing · 20 docs
Site & exterior2p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
2350 EAST 1ST STREET LLC303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/01/2023$995K—Private party → Private party$663/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DERMAN ENGINEERING PLLC411/11/2025
GARFINKEL ARCHITECT, PLLC511/07/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
4444 PPPP CORP1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
UPSTRATE INCGeneral Contractor507/08/2026
GREGG NY PLUMBING, INCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CITY-WIDE TESTING INC416811/11/2025
Building Lifecycle
All (89)Filed (9)Permit Issued (6)Violation (11)Inspection (3)Objection (30)Special Inspection (30)
05/01/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/01/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/01/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/08/2026
Permit issued — Mechanical Systems
B01206857-S4-MS
12/30/2025
Permit issued — General Construction
B01206857-I1-GC
12/19/2025
Special inspection requirement — Fenestration air leakage
ELIAS RASABI
12/19/2025
Special inspection requirement — Air barrier — testing
ELIAS RASABI
12/19/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
ELIAS RASABI
12/19/2025
Special inspection requirement — Electric vehicle service equipment requirements
ELIAS RASABI
12/19/2025
Special inspection requirement — Air barrier - visual inspection
ELIAS RASABI
12/19/2025
Special inspection requirement — Protection of exposed foundation insulation
ELIAS RASABI
12/19/2025
Special inspection requirement — Insulation placement and R values
ELIAS RASABI
12/19/2025
Special inspection requirement — Permanent certificate
ELIAS RASABI
12/19/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
ELIAS RASABI
12/19/2025
Special inspection requirement — Subgrade Inspections
ELIAS RASABI
12/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ELIAS RASABI
12/19/2025
Special inspection requirement — Concrete - Cast-In-Place
ELIAS RASABI
12/19/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ELIAS RASABI
12/19/2025
Special inspection requirement — Fire-Resistance Rated Construction
ELIAS RASABI
12/19/2025
Special inspection requirement — Energy Code Compliance Inspections
ELIAS RASABI
12/19/2025
Special inspection requirement — Interior lighting power
ELIAS RASABI
12/19/2025
Special inspection requirement — Fenestration areas
ELIAS RASABI
12/17/2025
Objection resolved — Addressed
12/11/2025
Permit issued — Plumbing
B01206857-S1-PL
12/04/2025
Permit issued — Structural
B01206857-S3-ST
12/04/2025
Permit issued — Foundation
B01206857-S2-FO
11/20/2025
Objection raised — Plumbing
11/18/2025
Permit issued — Construction Fence
B01221660-I1-FN
11/11/2025
Filed — Alteration CO
Plumbing work in conjunction with DOB NOW #B01160267-I1.
B01206857-P2
11/11/2025
Filed — Alteration CO
Plumbing work in conjunction with DOB NOW #B01160267-I1.
B01206857-P3
11/11/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
11/11/2025
Special inspection requirement — Structural Steel - Welding
11/07/2025
Filed — Alteration CO
Plumbing work in conjunction with DOB NOW #B01160267-I1.
B01206857-P1
11/06/2025
Special inspection requirement — Structural Wood Frame
ELIAS RASABI
11/06/2025
Special inspection requirement — Footing and Foundation
ELIAS RASABI
11/06/2025
Special inspection requirement — Concrete - Cast-In-Place
ELIAS RASABI
11/06/2025
Special inspection requirement — Masonry
ELIAS RASABI
11/06/2025
Special inspection requirement — Post-installed Anchors
ELIAS RASABI
11/06/2025
Special inspection requirement — Structural Cold-Formed Steel
ELIAS RASABI
11/06/2025
Special inspection requirement — Structural Steel - Details
ELIAS RASABI
11/06/2025
Special inspection requirement — Structural Steel - High Strength Bolting
ELIAS RASABI
11/06/2025
Special inspection requirement — Final
ELIAS RASABI
11/06/2025
Special inspection requirement — Concrete - Cast-In-Place
ELIAS RASABI
11/06/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
ELIAS RASABI
08/29/2025
Objection resolved — Addressed
06/27/2025
Objection raised — Admin
06/26/2025
Objection resolved — Addressed
06/23/2025
Filed — Alteration CO
Plumbing work in conjunction with DOB NOW #B01160267-I1.
B01206857-S4
06/13/2025
Objection raised — Other
06/11/2025
Filed — Alteration CO
Plumbing work in conjunction with DOB NOW #B01160267-I1.
B01206857-S2
06/05/2025
Objection resolved — Addressed
06/04/2025
Objection resolved — Addressed
05/28/2025
Objection raised — Energy
05/23/2025
Objection resolved — Addressed
05/20/2025
Objection raised — Other
05/19/2025
Objection raised — Other
05/14/2025
Filed — Alteration CO
Plumbing work in conjunction with DOB NOW #B01160267-I1.
B01206857-S3
05/13/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/13/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/12/2025
Filed — Alteration CO
Plumbing work in conjunction with DOB NOW #B01160267-I1.
B01206857-S1
Latest 60 of 89 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedUPSTRATE INC01/08/2026
DOB NOWGeneral ConstructionPermit IssuedUPSTRATE INC12/30/2025
DOB NOWPlumbingPermit IssuedGREGG NY PLUMBING, INC12/11/2025
DOB NOWStructuralPermit IssuedUPSTRATE INC12/04/2025
DOB NOWFoundationPermit IssuedUPSTRATE INC12/04/2025
DOB NOWConstruction FencePermit IssuedUPSTRATE INC11/18/2025
1 project · most recent 11/11/2025
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/11/2025Permit IssuedUPSTRATE INCAir Conditioning Systems, Ventilation Systems
Cooling
Carrier 40MBABQ60XA3 5 tons · Fan Coil Indoor ×2
R4A4S60AKANA 5 tons · Condensing Unit ×2
Ventilation
Delta Breeze BreezProfessional Pro300 300 CFM · Exhaust Fan ×5
Best P195P1M70SB 490 CFM · Exhaust Fan ×1
1 project · most recent 11/11/2025
Gas Water/Sanitary
FiledStatusContractorScope
11/11/2025Permit IssuedSUPER MAX CONSULTING INCGas, Water/Sanitary
1 project · most recent 04/30/2025
General Wiring
FiledStatusContractorScope
04/30/2025Permit IssuedKINGS ELECTRIC CO., INC.General Wiring
1 project · most recent 11/11/2025
Steel Concrete Masonry Wood
FiledStatusContractorScope
11/11/2025Permit IssuedUPSTRATE INCSteel, Concrete, Masonry, Wood
1 project · most recent 05/12/2025
Fence
FiledStatusContractorScope
05/12/2025Permit IssuedUPSTRATE INCFence
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
05/01/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/01/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/01/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 59
DateRequirementInspectorRole
12/19/2025Fenestration air leakageELIAS RASABIenergy_progress
12/19/2025Air barrier — testing ELIAS RASABIenergy_progress
12/19/2025Fenestration and door U-factor and product ratingsELIAS RASABIenergy_progress
12/19/2025Electric vehicle service equipment requirementsELIAS RASABIenergy_progress
12/19/2025Air barrier - visual inspectionELIAS RASABIenergy_progress
12/19/2025Protection of exposed foundation insulationELIAS RASABIenergy_progress
12/19/2025Insulation placement and R valuesELIAS RASABIenergy_progress
12/19/2025Permanent certificateELIAS RASABIenergy_progress
12/19/2025Exterior Insulation and Finish Systems (EIFS)ELIAS RASABIspecial
12/19/2025Subgrade InspectionsELIAS RASABIspecial
12/19/2025Fire-Resistant Penetrations and JointsELIAS RASABIspecial
12/19/2025Concrete - Cast-In-PlaceELIAS RASABIspecial
12/19/2025Structural Stability – Alterations of existing buildingsELIAS RASABIspecial
12/19/2025Fire-Resistance Rated ConstructionELIAS RASABIprogress
12/19/2025Energy Code Compliance InspectionsELIAS RASABIprogress
12/19/2025Interior lighting powerELIAS RASABIenergy_progress
12/19/2025Fenestration areasELIAS RASABIenergy_progress
11/11/2025Structural Stability – Alterations of existing buildings—special
11/11/2025Structural Steel - Welding—special
11/06/2025Structural Wood FrameELIAS RASABIprogress
11/06/2025Footing and FoundationELIAS RASABIprogress
11/06/2025Concrete - Cast-In-PlaceELIAS RASABIspecial
11/06/2025MasonryELIAS RASABIspecial
11/06/2025Post-installed AnchorsELIAS RASABIspecial
11/06/2025Structural Cold-Formed SteelELIAS RASABIspecial
Latest 25 of 59.
▾Documents — 74 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/21/2026B01221660-I1Request digital key ↗
08/21/2026B01206857-P4Request digital key ↗
08/21/2026B01206857-P3Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records8
▸DOB NOWZD1: DOB Zoning Diagram3
08/21/2026B01206857-I1Open ↗
08/21/2026B01206857-P4Open ↗
08/13/2026B01206857-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)3
08/21/2026B01206857-P4Open ↗
08/21/2026B01206857-I1Open ↗
08/13/2026B01206857-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/21/2026B01206857-I1Open ↗
08/13/2026B01206857-P1Open ↗
▸Seals & Professional Certifications26
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/21/2026B01221660-I1Open ↗
08/21/2026B01206857-S3Open ↗
08/21/2026B01206857-S2Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature9
09/01/2026B01206857-S4Open ↗
09/01/2026B01206857-S4Open ↗
09/01/2026B01206857-S4Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/01/2026B01206857-S4Open ↗
08/30/2026B01206857-P2Open ↗
08/27/2026B01206857-P1Open ↗
Showing 3 of 7 on file for this type
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/21/2026B01206857-I1Open ↗
08/21/2026B01206857-P4Open ↗
08/13/2026B01206857-P1Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/21/2026B01206857-P4Open ↗
08/21/2026B01206857-I1Open ↗
08/13/2026B01206857-P1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/21/2026B01206857-S3Open ↗
08/21/2026B01206857-S2Open ↗
08/21/2026B01206857-I1Open ↗
Showing 3 of 9 on file for this type
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026B01206857-S2Open ↗
▸Other Documents14
▸DOB NOWPlot Diagram5
08/21/2026B01206857-P4Open ↗
08/21/2026B01206857-I1Open ↗
08/21/2026B01206857-S2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSite Survey: Initial3
08/21/2026B01206857-P4Open ↗
08/21/2026B01206857-I1Open ↗
08/13/2026B01206857-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/21/2026B01206857-P4Open ↗
08/21/2026B01206857-I1Open ↗
08/13/2026B01206857-P1Open ↗
▸DOB NOWProperty Ownership Certification3
08/21/2026B01206857-I1Open ↗
08/21/2026B01206857-P4Open ↗
08/13/2026B01206857-P1Open ↗