← Back
Two family brick
2350 PROSPECT AVENUE
BRONX · Belmont · BIN 2013044
💬 Discuss this project
1901Year Built
2Stories
B1Building Class
R7-1Zoning
2,060 sfGross Floor Area
2Units
3 Open Violations ▸
Two family brick · 1,755 sf lot · 1.17 FAR built · Flood zone X
Locations of Work
ArchitectureGeneral
Roof3p · 1 filing · 9 docs
Cellar3p · 2 filings · 6 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC106/24/2024
EACADO DESIGNERS ASSOCIATES, INC208/31/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
E&A DESIGN AND EXPEDITER CORP.403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CENTURION SOLAR ENERGYGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854106/24/2024
HRF SERVICES CORP5616108/31/2022
Building Lifecycle
All (40)Filed (3)Permit Issued (1)Signed Off (1)Violation (21)Objection (8)Special Inspection (6)
03/06/2025
Signed off — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
X01064136-I1
07/17/2024
Permit issued — Solar
X01064136-I1-SL
07/09/2024
Objection resolved — Addressed
07/09/2024
Objection resolved — Addressed
07/09/2024
Objection resolved — Addressed
07/09/2024
Objection resolved — Addressed
07/01/2024
Objection raised — Structural
07/01/2024
Objection raised — Other
07/01/2024
Objection raised — Scope
07/01/2024
Objection raised — Scope
06/24/2024
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
X01064136-I1
06/10/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
06/10/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
06/10/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
06/10/2024
Special inspection requirement — Final
TOM PETERSEN
06/10/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
08/31/2022
Filed — Alteration
X00789541-I1
08/31/2022
Filed — Alteration
JOB FILED FOR CORRECT ECB VIOLATION #'S 39046067L & 39046069P IN EXISTING TWO FAMILY HOUSE. RESTORED THE PREMISE TO LEGAL CONDITIONS. NO CHANGE IN USE, OCCUPANCY OR MEANS OF EGRESS.
X00789558-I1
08/08/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/17/2022
Violation issued (ECB, closed)
Construction
02/17/2022
Violation issued (ECB, closed)
Construction
02/17/2022
Violation issued (ECB, closed)
Construction
02/17/2022
Violation issued (ECB, closed)
Construction
12/03/2021
Violation issued (ECB, closed)
Construction
12/03/2021
Violation issued (ECB, closed)
Construction
12/03/2021
Violation issued (ECB, closed)
Construction
12/03/2021
Violation issued (ECB, closed)
Construction
11/10/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/10/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/10/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/10/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/13/2021
Violation issued (ECB, closed)
Construction
10/13/2021
Violation issued (ECB, closed)
Construction
10/13/2021
Violation issued (ECB, closed)
Construction
10/13/2021
Violation issued (ECB, closed)
Construction
08/16/2021
Violation issued (ECB, open)
Construction
08/16/2021
Violation issued (ECB, open)
Construction
08/16/2021
Violation issued (ECB, open)
Construction
08/16/2021
Violation issued (ECB, closed)
Construction
02/17/1998
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offCENTURION SOLAR ENERGY07/17/2024
1 project · most recent 08/31/2022
Gas Water/Sanitary
FiledStatusContractorScope
08/31/2022——Gas, Water/Sanitary
3 projects · most recent 07/19/2024
General Wiring
FiledStatusContractorScope
07/19/2024CompleteBERGER QUALITY ELEC'L CON—
04/19/2022CompleteJOE ELECTRICAL INCGeneral Wiring
03/04/2022CompleteJOE ELECTRICAL INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
06/10/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
06/10/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
06/10/2024Energy Code Compliance InspectionsTOM PETERSENprogress
06/10/2024FinalTOM PETERSENprogress
06/10/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
08/08/2022Fire-Resistant Penetrations and Joints—special
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026X00789541-I1Request digital key ↗
08/24/2026X00789558-I1Request digital key ↗
08/21/2026X01064136-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026X00789558-I1Open ↗
08/21/2026X01064136-I1Open ↗
08/13/2026X00789541-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/24/2026X01064136-I1Open ↗
08/24/2026X01064136-I1Open ↗
08/24/2026X01064136-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026X01064136-I1Open ↗
08/24/2026X01064136-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/24/2026X00789558-I1Open ↗
08/21/2026X01064136-I1Open ↗
08/13/2026X00789541-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01064136-I1Open ↗