← Back
Two family brick
236 88 STREET
BROOKLYN · BIN 3154002
💬 Discuss this project
1905Year Built
2Stories
B1Building Class
R3-2Zoning
2,240 sfGross Floor Area
2Units
Two family brick · 2,000 sf lot · 1.12 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbingGeneral
Floor 11p · 2 filings · 20 docs
Cellar8p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/13/2023$1.3M—Private party → Private party$585/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BASIC GROUPS CORP401/07/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BASIC GROUPS803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
STEEL TONE CONSTRUCTIONGeneral Contractor107/08/2026
G & J PLMBNG AND HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ANDREW GOODRICH, P.E., PL965401/07/2025
Building Lifecycle
All (22)Filed (4)Permit Issued (2)Signed Off (2)Inspection (5)Special Inspection (9)
01/16/2025
Signed off — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK IN CONJUNCTION WITH OT JOB#B01080028-I1. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01088462-I1
01/15/2025
Signed off — Alteration
PROPOSED INTERIOR RENOVATION OF EXISTING FLOORS. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
B01080028-I1
01/14/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
01/07/2025
Filed — Alteration
PROPOSED INTERIOR RENOVATION OF EXISTING FLOORS. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
B01080028-P1
01/07/2025
Special inspection requirement — Lighting controls
ANDREW GOODRICH
01/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANDREW GOODRICH
01/07/2025
Special inspection requirement — Fire-Resistance Rated Construction
ANDREW GOODRICH
01/07/2025
Special inspection requirement — Energy Code Compliance Inspections
ANDREW GOODRICH
01/07/2025
Special inspection requirement — Interior lighting power
ANDREW GOODRICH
12/24/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
12/02/2024
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK IN CONJUNCTION WITH OT JOB#B01080028-I1. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01088462-P1
12/02/2024
Special inspection requirement — Energy Code Compliance Inspections
ANDREW GOODRICH
12/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANDREW GOODRICH
11/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANDREW GOODRICH
11/29/2024
Special inspection requirement — Energy Code Compliance Inspections
ANDREW GOODRICH
11/18/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/19/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/19/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/07/2024
Permit issued — Plumbing
B01088462-I1-PL
08/02/2024
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK IN CONJUNCTION WITH OT JOB#B01080028-I1. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01088462-I1
07/18/2024
Permit issued — General Construction
B01080028-I1-GC
07/16/2024
Filed — Alteration
PROPOSED INTERIOR RENOVATION OF EXISTING FLOORS. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
B01080028-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offG & J PLMBNG AND HTG INC08/07/2024
DOB NOWGeneral ConstructionSigned-offSTEEL TONE CONSTRUCTION07/18/2024
1 project · most recent 01/17/2024
General Wiring
FiledStatusContractorScope
01/17/2024Permit IssuedKINGS ELECTRIC CO., INC.General Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
01/14/2025Pass-Final General Construction Non-Directive 14PassView ↗
12/24/2024Fail-Final General Construction Non-Directive 14FailView ↗
11/18/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/19/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/19/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
01/07/2025Lighting controlsANDREW GOODRICHenergy_progress
01/07/2025Fire-Resistant Penetrations and JointsANDREW GOODRICHspecial
01/07/2025Fire-Resistance Rated ConstructionANDREW GOODRICHprogress
01/07/2025Energy Code Compliance InspectionsANDREW GOODRICHprogress
01/07/2025Interior lighting powerANDREW GOODRICHenergy_progress
12/02/2024Energy Code Compliance InspectionsANDREW GOODRICHprogress
12/02/2024Fire-Resistant Penetrations and JointsANDREW GOODRICHspecial
11/29/2024Fire-Resistant Penetrations and JointsANDREW GOODRICHspecial
11/29/2024Energy Code Compliance InspectionsANDREW GOODRICHprogress
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/24/2026B01080028-I1Request digital key ↗
08/24/2026B01080028-P1Request digital key ↗
08/24/2026B01088462-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/24/2026B01088462-I1Open ↗
08/13/2026B01088462-P1Open ↗
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/24/2026B01088462-I1Open ↗
08/24/2026B01088462-P1Open ↗
08/13/2026B01080028-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026B01088462-I1Open ↗
08/25/2026B01088462-P1Open ↗
08/23/2026B01080028-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026B01088462-I1Open ↗
08/25/2026B01088462-P1Open ↗
08/23/2026B01080028-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/24/2026B01088462-P1Open ↗
08/24/2026B01088462-I1Open ↗
08/13/2026B01080028-I1Open ↗
Showing 3 of 4 on file for this type