← Back
Two family converted from one family
238 COLERIDGE STREET
BROOKLYN · BIN 3429617
💬 Discuss this project
1920Year Built
2Stories
B3Building Class
R3-1Zoning
3,060 sfGross Floor Area
2Units
Two family converted from one family · Owner of record: 238COL LLC · 5,500 sf lot · 0.56 FAR built · Flood zone X500
Locations of Work
Architecture
Floor 11 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/20/2022$2.2M—— → —$727/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ZPROEKT ARCHITECTURE209/06/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HM CONSULTING EXPEDITING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KADAR ELITE CONSTRUCTIONGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519209/06/2024
Building Lifecycle
All (27)Filed (2)Permit Issued (1)Inspection (2)Objection (14)Special Inspection (8)
10/08/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/25/2024
Special inspection requirement — Final
NAVEEN KUMAR
09/25/2024
Special inspection requirement — Concrete - Cast-In-Place
Younes Abouyaala
09/25/2024
Special inspection requirement — Footing and Foundation
Younes Abouyaala
09/25/2024
Special inspection requirement — Lowest Floor Elevation
Younes Abouyaala
09/09/2024
Objection raised — Admin
09/09/2024
Objection resolved — Addressed
09/06/2024
Filed — New Building
proposed accessory use one car garage in conjunction with NB#B00844077-I1. Curb cut filed under B00844077-S2
B00871671-P1
09/06/2024
Special inspection requirement — Concrete - Cast-In-Place
Younes Abouyaala
09/06/2024
Special inspection requirement — Final
NAVEEN KUMAR
09/06/2024
Special inspection requirement — Footing and Foundation
Younes Abouyaala
09/06/2024
Special inspection requirement — Lowest Floor Elevation
Younes Abouyaala
09/05/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
09/25/2023
Permit issued — General Construction
B00871671-I1-GC-CX
06/13/2023
Objection resolved — Addressed
06/06/2023
Objection resolved — Addressed
06/06/2023
Objection resolved — Addressed
05/18/2023
Objection resolved — Addressed
05/17/2023
Objection raised — Structural
05/17/2023
Objection raised — Structural
05/17/2023
Objection resolved — Addressed
05/17/2023
Objection raised — Structural
05/17/2023
Objection raised — Zoning
05/17/2023
Objection raised — Zoning
05/17/2023
Objection resolved — Addressed
05/17/2023
Objection raised — Structural
05/12/2023
Filed — New Building
proposed accessory use one car garage in conjunction with NB#B00844077-I1. Curb cut filed under B00844077-S2
B00871671-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedKADAR ELITE CONSTRUCTION09/25/2023
1 project · most recent 09/06/2024
General Wiring
FiledStatusContractorScope
09/06/2024CompleteCMY ELECTRICAL CORPGeneral Wiring
1 project · most recent 09/06/2024
Concrete
FiledStatusContractorScope
09/06/2024Permit IssuedKADAR ELITE CONSTRUCTIONConcrete
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
10/08/2024Pass-Final CND-Occupancy InspectionPassView ↗
09/05/2024Fail-Final CND-Occupancy InspectionFailView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
09/25/2024FinalNAVEEN KUMARprogress
09/25/2024Concrete - Cast-In-PlaceYounes Abouyaalaspecial
09/25/2024Footing and FoundationYounes Abouyaalaprogress
09/25/2024Lowest Floor ElevationYounes Abouyaalaprogress
09/06/2024Concrete - Cast-In-PlaceYounes Abouyaalaspecial
09/06/2024FinalNAVEEN KUMARprogress
09/06/2024Footing and FoundationYounes Abouyaalaprogress
09/06/2024Lowest Floor ElevationYounes Abouyaalaprogress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/15/2026B00871671-P1Request digital key ↗
08/14/2026B00871671-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026B00871671-P1Open ↗
08/13/2026B00871671-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026B00871671-I1Open ↗
08/13/2026B00871671-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00871671-I1Open ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
08/31/2026B00871671-P1Open ↗
08/31/2026B00871671-P1Open ↗
08/24/2026B00871671-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/31/2026B00871671-P1Open ↗
08/24/2026B00871671-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026B00871671-I1Open ↗
08/24/2026B00871671-P1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/15/2026B00871671-P1Open ↗
08/14/2026B00871671-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026B00871671-I1Open ↗
▸Other Documents8
▸DOB NOWSite Survey: Initial2
08/13/2026B00871671-I1Open ↗
08/13/2026B00871671-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B00871671-P1Open ↗
08/13/2026B00871671-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/15/2026B00871671-P1Open ↗
08/14/2026B00871671-I1Open ↗
▸DOB NOWFEMA Elevation Certificate (086-0-33)/Flood Proofing Certificate (086-0-34)1
08/13/2026B00871671-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00871671-I1Open ↗