BuildNYC
Walk-up apt, over six families with stores
238 MOTT STREET
MANHATTAN · BIN 1007478
💬 Discuss this project
1900Year Built
6Stories
C7Building Class
C6-2Zoning
15,534 sfGross Floor Area
30Units
Rent Stabilized3 Active Violations ▸
Walk-up apt, over six families with stores · Owner of record: Hop Hing Realty · 2,825 sf lot · 5.5 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofBONI Restaurant2p · 1 filing · 16 docs
Floor 6BONI Restaurant, Unit 6C6p · 2 filings · 19 docs
Floor 5BONI Restaurant2p · 1 filing · 16 docs
Floor 4BONI Restaurant2p · 1 filing · 16 docs
Floor 3BONI Restaurant, Unit 3E6p · 2 filings · 19 docs
Floor 2BONI Restaurant2p · 1 filing · 16 docs
Floor 1BONI Restaurant, Hop Yick Co27p · 5 filings · 20 docs
CellarBONI Restaurant19p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Hop Hing Realty3903/22/2026
Hop Yick Co1303/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Apex Energy Solutions309/23/2024
KDV Designs Architects110/20/2023
LNZ103/15/2023
MW Professional Engineering305/23/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB Building Consulting803/21/2026
TBC & Associates203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
H&M ContractorsGeneral Contractor403/21/2026
Lambo ConstructionGeneral Contractor407/08/2026
Master Fire MechanicalGeneral Contractor303/21/2026
F.G.E. Electrical ContgElectrical103/21/2026
AMC Plumbing, Heating & CLNGPlumbing107/08/2026
American Standard P&H CororpPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Synergy Engineering784509/23/2024
MW Professional Engineering570202/23/2022
Building Lifecycle
All (108)Filed (8)Permit Issued (7)Signed Off (7)Violation (60)Inspection (5)Objection (4)Special Inspection (17)
04/29/2026
Violation issued (HPD, closed)
A
06/04/2025
Violation issued (HPD, closed)
A
03/24/2025
Signed off — Alteration
INSTALLING NEW COMMERCIAL KITCHEN COOKING VENTILATION SYSTEM. NEW S/S EXHAUST HOOD WITH NEW EXHAUST/MUA DUCTS AND NEW EXHAUST/MUA FANS TO BE INSTALLED AS PER PLANS. NO OTHER WORK TO BE DONE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00817708-S1
01/02/2025
Signed off — Alteration
INSTALLING NEW COMMERCIAL KITCHEN COOKING VENTILATION SYSTEM. NEW S/S EXHAUST HOOD WITH NEW EXHAUST/MUA DUCTS AND NEW EXHAUST/MUA FANS TO BE INSTALLED AS PER PLANS. NO OTHER WORK TO BE DONE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00817708-I1
12/11/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/07/2024
Special inspection requirement — Tenant Protection Plan Compliance
Alec Strongin
10/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alec Strongin
10/07/2024
Special inspection requirement — Energy Code Compliance Inspections
Alec Strongin
10/07/2024
Special inspection requirement — Maintenance information
Alec Strongin
10/07/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Alec Strongin
10/07/2024
Special inspection requirement — HVAC-R and service water heating system controls
Alec Strongin
10/07/2024
Special inspection requirement — HVAC-R and service water heating equipment
Alec Strongin
09/23/2024
Filed — Alteration
INSTALLING NEW COMMERCIAL KITCHEN COOKING VENTILATION SYSTEM. NEW S/S EXHAUST HOOD WITH NEW EXHAUST/MUA DUCTS AND NEW EXHAUST/MUA FANS TO BE INSTALLED AS PER PLANS. NO OTHER WORK TO BE DONE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00817708-P1
05/22/2024
Signed off — Alteration
Proposed Interior Renovation in Existing Eating &Drinking Establishment with New Partitions, and Finish Work @ 1st floor, as per plan., Mechanical and Plumbing work filed under separate applications. No change in use, egress, and occupancy.
M00817702-I1
05/22/2024
Signed off — Alteration
Propose Mechanical work in conjunction with Arch design. No change in use, egress, and occupancy.
M00817704-I1
12/13/2023
Permit issued — Mechanical Systems
M00817708-S1-MS
11/17/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/17/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/20/2023
Filed — Alteration
INSTALLING NEW COMMERCIAL KITCHEN COOKING VENTILATION SYSTEM. NEW S/S EXHAUST HOOD WITH NEW EXHAUST/MUA DUCTS AND NEW EXHAUST/MUA FANS TO BE INSTALLED AS PER PLANS. NO OTHER WORK TO BE DONE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00817708-S1
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
C
09/12/2023
Violation issued (HPD, closed)
A
09/12/2023
Violation issued (HPD, closed)
A
09/12/2023
Violation issued (HPD, closed)
A
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
C
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
A
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
A
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
B
09/12/2023
Violation issued (HPD, closed)
A
09/12/2023
Violation issued (HPD, closed)
A
09/08/2023
Permit issued — Plumbing
M00817708-I1-PL
08/10/2023
Permit issued — Mechanical Systems
M00817704-I1-MS
07/03/2023
Violation issued (HPD, closed)
C
07/03/2023
Violation issued (HPD, closed)
B
06/29/2023
Violation issued (HPD, closed)
C
06/13/2023
Permit issued — General Construction
M00817702-I1-GC
04/02/2023
Objection raised — Admin
04/02/2023
Objection resolved — Addressed
03/27/2023
Filed — Alteration
INSTALLING NEW COMMERCIAL KITCHEN COOKING VENTILATION SYSTEM. NEW S/S EXHAUST HOOD WITH NEW EXHAUST/MUA DUCTS AND NEW EXHAUST/MUA FANS TO BE INSTALLED AS PER PLANS. NO OTHER WORK TO BE DONE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00817708-I1
03/27/2023
Filed — Alteration
Propose Mechanical work in conjunction with Arch design. No change in use, egress, and occupancy.
M00817704-I1
03/25/2023
Objection raised — Admin
03/25/2023
Objection resolved — Addressed
03/15/2023
Filed — Alteration
Proposed Interior Renovation in Existing Eating &Drinking Establishment with New Partitions, and Finish Work @ 1st floor, as per plan., Mechanical and Plumbing work filed under separate applications. No change in use, egress, and occupancy.
M00817702-I1
03/15/2023
Violation issued (HPD, closed)
A
03/01/2023
Special inspection requirement — Tenant Protection Plan Compliance
Alec Strongin
02/23/2023
Special inspection requirement — Shutoff dampers
Alec Strongin
02/23/2023
Special inspection requirement — Energy Code Compliance Inspections
Alec Strongin
02/23/2023
Special inspection requirement — HVAC-R and service water heating equipment
Alec Strongin
02/23/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Alec Strongin
02/23/2023
Special inspection requirement — Duct leakage testing, insulation and design
Alec Strongin
Latest 60 of 108 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offMaster Fire Mechanical12/13/2023
DOB NOWPlumbingSigned-offAmerican Standard P&H Cororp09/08/2023
DOB NOWMechanical SystemsSigned-offLambo Construction08/10/2023
DOB NOWGeneral ConstructionSigned-offLambo Construction06/13/2023
DOB NOWPlumbingSigned-offAMC Plumbing, Heating & CLNG06/10/2022
DOB NOWGeneral ConstructionSigned-offH&M Contractors03/28/2022
DOB NOWGeneral ConstructionSigned-offH&M Contractors11/21/2021
BISOTISSUEDH&M Contractors02/12/2019
BISOTISSUEDH&M Contractors12/03/2018
BISOTISSUEDH&M Contractors04/06/2015
BISOTISSUEDH&M Contractors12/03/2014
BISPLISSUEDBell Fuel Oil06/25/2014
BISFBISSUEDApproved Oil Co of Brooklyn06/25/2014
BISOTISSUEDH&M Contractors12/17/2012
BISOTISSUEDH&M Contractors12/20/2011
BISOTISSUEDH&M Contractors11/14/2011
BISEQISSUEDRock Scaffolding10/13/2011
BISEQISSUEDRock Scaffolding10/13/2011
BISPLRE-ISSUEDHourie's Plumbing & Heating06/22/2010
BISEQISSUEDMadison Construction Cons05/05/2010
BISOTISSUEDMadison Construction Cons05/05/2010
BISOTISSUEDH&M Contractors03/13/2009
BISOTISSUEDH&M Contractors08/24/2008
BISOTISSUEDH&M Contractors07/23/2008
BISPLISSUEDRRP Plumbing11/02/2007
BISOTISSUEDH&M Contractors10/17/2005
BISFBISSUEDAtedg HTS Cooling03/26/2004
BISOTISSUEDH&M Contractors11/10/2003
BISOTISSUEDAmerican Advertising05/24/2000
BISOTISSUEDJose G.leal09/04/1996
BISFPISSUEDIleal Fire Control05/14/1992
1 project · most recent 11/03/2022
FiledStatusContractorScope
11/03/2022Permit IssuedGoodall Electric3 meters, 3 new_meters
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
12/11/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/17/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/17/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/14/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/17/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
10/07/2024Tenant Protection Plan ComplianceAlec Stronginspecial
10/07/2024Fire-Resistant Penetrations and JointsAlec Stronginspecial
10/07/2024Energy Code Compliance InspectionsAlec Stronginprogress
10/07/2024Maintenance informationAlec Stronginenergy_progress
10/07/2024HVAC-R and service water piping design and insulationAlec Stronginenergy_progress
10/07/2024HVAC-R and service water heating system controlsAlec Stronginenergy_progress
10/07/2024HVAC-R and service water heating equipmentAlec Stronginenergy_progress
03/01/2023Tenant Protection Plan ComplianceAlec Stronginspecial
02/23/2023Shutoff dampersAlec Stronginenergy_progress
02/23/2023Energy Code Compliance InspectionsAlec Stronginprogress
02/23/2023HVAC-R and service water heating equipmentAlec Stronginenergy_progress
02/23/2023HVAC-R and service water piping design and insulationAlec Stronginenergy_progress
02/23/2023Duct leakage testing, insulation and designAlec Stronginenergy_progress
02/23/2023HVAC-R and service water heating system controlsAlec Stronginenergy_progress
02/23/2023Maintenance informationAlec Stronginenergy_progress
01/24/2023FinalAlec Stronginprogress
01/24/2023Mechanical SystemsAlec Stronginspecial
▾Tenants in the building
TenantSpaceFloorsRenovation projects
BONI RestaurantRestaurant / Food ServiceCellar, Floors 1–6, Roof
Project M00817704 Alteration · LOC Issued · 03/27/2023
Project M00817708 Alteration · LOC Issued · 03/27/2023
Project M00817702 Alteration · LOC Issued · 03/15/2023
Hop Yick CoRetailFloor 1
Project M00686750 Alteration · LOC Issued · 05/23/2022
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 275 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
09/03/2026M00630985-I1Request digital key ↗
09/02/2026M00597169-I1Request digital key ↗
09/02/2026M00686750-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits42
▸BISPLAN / WORK APPROVAL APPLICATION24
11/06/2019123740345Open ↗
02/12/2019123405252Open ↗
01/29/2019123250828Open ↗
Showing 3 of 24 on file for this type
▸BISWORK PERMIT APPLICATION17
02/13/2019123405252Open ↗
12/04/2018123405252Open ↗
04/14/2015140284626Open ↗
Showing 3 of 17 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
12/03/2018123405252Open ↗
▸Seals & Professional Certifications80
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION26
02/24/2020123740345Open ↗
11/06/2019123740345Open ↗
04/25/2019123405252Open ↗
Showing 3 of 26 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
08/25/2026M00817704-I1Open ↗
08/25/2026M00817704-I1Open ↗
08/25/2026M00817704-I1Open ↗
Showing 3 of 13 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST12
12/03/2018123405252Open ↗
09/11/2013121761664Open ↗
12/20/2011120924474Open ↗
Showing 3 of 12 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM10
09/11/2013121761664Open ↗
11/15/2011120896290Open ↗
10/17/2011120861031Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
09/03/2026M00630985-I1Open ↗
09/02/2026M00597169-I1Open ↗
09/02/2026M00686750-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/25/2026M00817704-I1Open ↗
08/25/2026M00817704-I1Open ↗
08/22/2026M00817708-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
12/03/2018123405252Open ↗
11/24/2014140284626Open ↗
12/14/2012140044388Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
11/24/2014140284626Open ↗
12/14/2012140044388Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
11/24/2014140284626Open ↗
12/14/2012140044388Open ↗
▸Trade Schedules & Equipment13
▸BISSELF-CERT PLUMBING NOTICE5
03/10/2015121761664Open ↗
09/02/2010120333692Open ↗
08/19/2010120333692Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE B - PLUMBING2
09/11/2013121761664Open ↗
05/05/2010120333692Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
01/12/2015121761664Open ↗
10/14/2014121761664Open ↗
▸BISEQUIPMENT USE APPLICATION-PERMIT2
04/26/2011120333692Open ↗
05/05/2010120333692Open ↗
▸BISEQUIPMENT USE PERMITS1
04/26/2011120333692Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
10/14/2014121761664Open ↗
▸Safety & Tenant Protection6
▸BISTenant Protection Plan and Notes3
03/12/2020123740345Open ↗
11/06/2019123740345Open ↗
01/29/2019123250828Open ↗
▸BISSTREET TREE CHECKLIST3
08/04/2009120122517Open ↗
Showing 1 of 3 on file for this type
▸Environmental & Asbestos27
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'9
12/20/2011120924474Open ↗
11/15/2011120896290Open ↗
10/14/2011120861031Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)9
02/13/2020123740345Open ↗
01/29/2019123250828Open ↗
12/03/2018123405252Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
09/03/2026M00630985-I1Open ↗
09/02/2026M00597169-I1Open ↗
09/02/2026M00686750-I1Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
08/04/2009120122517Open ↗
▸Energy Compliance19
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS8
11/06/2019123740345Open ↗
04/25/2019123405252Open ↗
01/29/2019123250828Open ↗
Showing 3 of 8 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
04/25/2019123405252Open ↗
10/01/2015121761664Open ↗
08/06/2015140284626Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
11/24/2014140284626Open ↗
12/14/2012140044388Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
11/24/2014140284626Open ↗
12/14/2012140044388Open ↗
▸BISTECHNICAL REPORT: ENERGY1
12/20/2011120924474Open ↗
▸BISTR8: Energy Code Progress Inspections1
09/11/2013121761664Open ↗
▸BISNYCECC ANALYSIS1
12/14/2012140044388Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026M00597169-I1Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
11/24/2014140284626Open ↗
12/14/2012140044388Open ↗
▸Approvals, Objections & Sign-offs26
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST10
04/25/2019123405252Open ↗
10/01/2015121761664Open ↗
08/06/2015140284626Open ↗
Showing 3 of 10 on file for this type
▸BISADMINISTRATIVE OBJECTIONS9
12/20/2011120924474Open ↗
11/15/2011120896290Open ↗
10/14/2011120861031Open ↗
Showing 3 of 9 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION7
04/25/2019123405252Open ↗
08/06/2015140284626Open ↗
12/18/2012120924474Open ↗
Showing 3 of 7 on file for this type
▸Cost, Insurance & Ownership25
▸BISCOST AFFIDAVIT22
11/06/2019123740345Open ↗
04/25/2019123405252Open ↗
01/29/2019123250828Open ↗
Showing 3 of 22 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT3
12/21/2011120924474Open ↗
08/05/2009120122517Open ↗
08/05/2009120122517Open ↗
▸Filing & Intake Forms27
▸BISEFILING COVER SHEET12
11/06/2019123740345Open ↗
01/29/2019123250828Open ↗
12/03/2018123405252Open ↗
Showing 3 of 12 on file for this type
▸BISADDITIONAL INFORMATION10
03/12/2020123740345Open ↗
03/25/2019123405252Open ↗
02/03/2015140284626Open ↗
Showing 3 of 10 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
11/24/2014140284626Open ↗
12/14/2012140044388Open ↗
Showing 2 of 3 on file for this type
▸BISBOROUGH INTAKE FORM2
04/25/2019123405252Open ↗
02/05/2019123405252Open ↗