← Back
Two family converted from one family
238 WYCKOFF STREET
BROOKLYN · BIN 3006215
💬 Discuss this project
1872Year Built
2Stories
B3Building Class
R6BZoning
2,840 sfGross Floor Area
2Units
Two family converted from one family · 2,000 sf lot · 1.42 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof6p · 2 filings · 9 docs
Floor 31p · 1 filing · 12 docs
Floor 29p · 2 filings · 15 docs
Floor 110p · 3 filings · 18 docs
Cellar6p · 1 filing · 9 docs
Basement7p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/30/2019$2.8M—Private party → Private party$986/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
M. GELLER ARCHITECT, PLLC605/09/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J A EXPEDITING1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
C.S. SCOTT ENTERPRISESGeneral Contractor707/08/2026
CROSSFIELD PLBG.&HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AK ENGINEERING PC678505/09/2024
Building Lifecycle
All (28)Filed (6)Permit Issued (4)Signed Off (1)Inspection (7)Objection (4)Special Inspection (6)
06/18/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/11/2024
Signed off — Alteration
HEREBY FILING FOR THE REPLACEMENT, RELOCATION AND INSTALLATION OF PLUMBING FIXTURES. NO CHANGE TO USE OCCUPANCY OR EGRESS.
B00487524-I1
06/03/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/09/2024
Filed — Alteration
HEREBY FILING FOR THE REPLACEMENT, RELOCATION AND INSTALLATION OF PLUMBING FIXTURES. NO CHANGE TO USE OCCUPANCY OR EGRESS.
B00487524-P2
05/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ari Kamo
04/25/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/25/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/13/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/02/2024
Permit issued — General Construction
B00814710-I1-GC
10/12/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/12/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/22/2023
Filed — Alteration
HEREBY FILING FOR THE REPLACEMENT, RELOCATION AND INSTALLATION OF PLUMBING FIXTURES. NO CHANGE TO USE OCCUPANCY OR EGRESS.
B00487524-P1
09/20/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ari Kamo
07/31/2023
Permit issued — Plumbing
B00487524-I1-PL
03/27/2023
Permit issued — General Construction
B00814710-I1-GC
03/27/2023
Permit issued — Mechanical Systems
B00814782-I1-MS
03/01/2023
Objection raised — Scope
03/01/2023
Objection resolved — Addressed
03/01/2023
Objection raised — Other
03/01/2023
Objection resolved — Addressed
02/28/2023
Filed — Alteration
HEREBY FILING FOR THE INSTALLATION OF MECHANICAL EQUIPMENT. ALL WORK AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
B00814782-I1
02/27/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ari Kamo
01/24/2023
Filed — Alteration CO
B00814710-I1
01/18/2023
Special inspection requirement — Fire-Resistance Rated Construction
Ari Kamo
01/18/2023
Special inspection requirement — Mechanical Systems
Ari Kamo
01/18/2023
Special inspection requirement — Final
Ari Kamo
04/14/2021
Filed — Alteration
HEREBY FILING FOR THE REPLACEMENT, RELOCATION AND INSTALLATION OF PLUMBING FIXTURES. NO CHANGE TO USE OCCUPANCY OR EGRESS.
B00487524-I1
04/14/2021
Filed — Alteration
B00487513-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedC.S. SCOTT ENTERPRISES02/02/2024
DOB NOWPlumbingSigned-offCROSSFIELD PLBG.&HTG07/31/2023
DOB NOWGeneral ConstructionPermit IssuedC.S. SCOTT ENTERPRISES03/27/2023
DOB NOWMechanical SystemsPermit IssuedC.S. SCOTT ENTERPRISES03/27/2023
1 project · most recent 02/28/2023
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
02/28/2023Permit IssuedC.S. SCOTT ENTERPRISESHeating and Air Conditioning Systems
Heat / Cool
York AE48CX21 4 tons · Ahu ×1
YCE48B21S 4 tons · Condensing Unit ×1
1 project · most recent 11/26/2024
General Wiring
FiledStatusContractorScope
11/26/2024CompleteJASON SALOME ELEC'L CONTGGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
06/18/2025Pass-Final CND-Occupancy InspectionPassView ↗
06/03/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/25/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/25/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/13/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/12/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/12/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
05/01/2024Fire-Resistant Penetrations and JointsAri Kamospecial
09/20/2023Fire-Resistant Penetrations and JointsAri Kamospecial
02/27/2023Fire-Resistant Penetrations and JointsAri Kamospecial
01/18/2023Fire-Resistance Rated ConstructionAri Kamoprogress
01/18/2023Mechanical SystemsAri Kamospecial
01/18/2023FinalAri Kamoprogress
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
09/01/2026B00487524-I1Request digital key ↗
09/01/2026B00487524-P2Request digital key ↗
09/01/2026B00487524-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits6
▸DOB NOWLPC Approval/Permit6
08/13/2026B00487524-P1Open ↗
08/13/2026B00487524-I1Open ↗
08/13/2026B00487513-I1Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature6
09/01/2026B00487524-P2Open ↗
09/01/2026B00487524-P1Open ↗
09/01/2026B00487524-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026B00814782-I1Open ↗
08/28/2026B00814710-I1Open ↗
08/27/2026B00487524-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B00814782-I1Open ↗
08/28/2026B00814710-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00814710-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026B00814710-I1Open ↗
▸Other Documents3
▸DOB NOWProof of Historic Building2
08/13/2026B00814782-I1Open ↗
08/13/2026B00814710-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026B00814710-I1Open ↗