← Back
Two family converted from one family
239 MADISON STREET
BROOKLYN · BIN 3051436
💬 Discuss this project
1882Year Built
2Stories
B3Building Class
R6BZoning
2,400 sfGross Floor Area
2Units
Rent Stabilized1 Open Violation ▸
Two family converted from one family · 2,000 sf lot · 1.2 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Floor 24p · 1 filing · 20 docs
Floor 15p · 1 filing · 20 docs
Cellar7p · 1 filing · 20 docs
Basement4p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BRICKSTONE GROUP1207/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/30/2025$2.8M—736 VERMONT BRICKS GROUP LLC → Private party$1,167/sf building
03/15/2024$1.3M—— → —$527/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CQ&J CORPORATION803/25/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WM ARCH1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MORELL BUILDERS INCGeneral Contractor407/08/2026
PLBG P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
D&E BUILD EVERGREEN I9342503/25/2025
Building Lifecycle
All (79)Filed (8)Permit Issued (3)Signed Off (2)Violation (19)Inspection (7)Objection (10)Special Inspection (30)
05/05/2026
Violation issued (HPD, closed)
A
06/10/2025
Violation issued (HPD, closed)
A
04/11/2025
Signed off — Alteration CO
REMOVED & REINSTALL PLUMBING SYSTEM THROUGHOUT EXISTING THREE (3) FAMILY, THREE (3) STORY AS PER PLANS.
B01043133-S2
04/10/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/01/2025
Special inspection requirement — Insulation placement and R values
CALVIN TRAN
04/01/2025
Special inspection requirement — Lighting in dwelling units
CALVIN TRAN
04/01/2025
Special inspection requirement — Final
CALVIN TRAN
04/01/2025
Special inspection requirement — Fire-Resistance Rated Construction
CALVIN TRAN
04/01/2025
Special inspection requirement — Metering
CALVIN TRAN
04/01/2025
Special inspection requirement — Fenestration air leakage
CALVIN TRAN
04/01/2025
Special inspection requirement — Fenestration areas
CALVIN TRAN
04/01/2025
Special inspection requirement — Structural Wood Frame
CALVIN TRAN
04/01/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Danny Chen
04/01/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Danny Chen
04/01/2025
Special inspection requirement — Air barrier - visual inspection
CALVIN TRAN
04/01/2025
Special inspection requirement — Permanent certificate
CALVIN TRAN
04/01/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
CALVIN TRAN
03/25/2025
Filed — Alteration CO
REMOVED & REINSTALL PLUMBING SYSTEM THROUGHOUT EXISTING THREE (3) FAMILY, THREE (3) STORY AS PER PLANS.
B01043133-P5
03/25/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Danny Chen
03/25/2025
Special inspection requirement — Metering
CALVIN TRAN
03/25/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Danny Chen
03/25/2025
Special inspection requirement — Air barrier - visual inspection
CALVIN TRAN
03/25/2025
Special inspection requirement — Lighting in dwelling units
CALVIN TRAN
03/25/2025
Special inspection requirement — Permanent certificate
CALVIN TRAN
03/25/2025
Special inspection requirement — Fire-Resistance Rated Construction
CALVIN TRAN
03/25/2025
Special inspection requirement — Fenestration areas
CALVIN TRAN
03/25/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
CALVIN TRAN
03/25/2025
Special inspection requirement — Structural Wood Frame
CALVIN TRAN
03/25/2025
Special inspection requirement — Final
CALVIN TRAN
03/25/2025
Special inspection requirement — Insulation placement and R values
CALVIN TRAN
03/25/2025
Special inspection requirement — Fenestration air leakage
CALVIN TRAN
03/20/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/13/2025
Special inspection requirement — Mechanical Systems
Danny Chen
03/13/2025
Special inspection requirement — Heating Systems
Danny Chen
03/13/2025
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
03/13/2025
Special inspection requirement — Final
CALVIN TRAN
03/12/2025
Signed off — Alteration CO
REMOVED & REINSTALL PLUMBING SYSTEM THROUGHOUT EXISTING THREE (3) FAMILY, THREE (3) STORY AS PER PLANS.
B01043133-S1
03/12/2025
Filed — Alteration CO
REMOVED & REINSTALL PLUMBING SYSTEM THROUGHOUT EXISTING THREE (3) FAMILY, THREE (3) STORY AS PER PLANS.
B01043133-P4
03/07/2025
Filed — Alteration CO
REMOVED & REINSTALL PLUMBING SYSTEM THROUGHOUT EXISTING THREE (3) FAMILY, THREE (3) STORY AS PER PLANS.
B01043133-P2
03/04/2025
Filed — Alteration CO
REMOVED & REINSTALL PLUMBING SYSTEM THROUGHOUT EXISTING THREE (3) FAMILY, THREE (3) STORY AS PER PLANS.
B01043133-P1
03/03/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/25/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/17/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/17/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/17/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/08/2024
Permit issued — Mechanical Systems
B01043133-S2-MS
10/07/2024
Permit issued — Plumbing
B01043133-S1-PL
10/02/2024
Filed — Alteration CO
REMOVED & REINSTALL PLUMBING SYSTEM THROUGHOUT EXISTING THREE (3) FAMILY, THREE (3) STORY AS PER PLANS.
B01043133-S2
10/02/2024
Filed — Alteration CO
REMOVED & REINSTALL PLUMBING SYSTEM THROUGHOUT EXISTING THREE (3) FAMILY, THREE (3) STORY AS PER PLANS.
B01043133-S1
09/06/2024
Permit issued — Structural
B01043133-I1-GC-CX
07/16/2024
Filed — Alteration
B01080231-I1
05/22/2024
Objection raised — Other
05/22/2024
Objection resolved — Addressed
05/22/2024
Objection raised — Other
05/22/2024
Objection resolved — Addressed
05/22/2024
Objection raised — Zoning
05/22/2024
Objection resolved — Addressed
05/22/2024
Objection raised — Admin
05/22/2024
Objection resolved — Addressed
05/22/2024
Objection raised — Zoning
Latest 60 of 79 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offMORELL BUILDERS INC10/08/2024
DOB NOWPlumbingSigned-offPLBG P & H INC10/07/2024
DOB NOWStructuralPermit IssuedMORELL BUILDERS INC09/06/2024
1 project · most recent 03/25/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/25/2025Signed-offMORELL BUILDERS INCHeating and Air Conditioning Systems
Heat / Cool
Daikin 3MXS24WMVJU9 24,000 BTU · Condensing Unit ×1
5MXS48WVJU9 47,000 BTU · Heat Pump Outdoor ×1
RXC09AXVJU 9,400 BTU · Condensing Unit ×1
1 project · most recent 03/25/2025
Gas Water/Sanitary
FiledStatusContractorScope
03/25/2025Signed-offPLBG P & H INCGas, Water/Sanitary
2 projects · most recent 04/01/2025
General Wiring
FiledStatusContractorScope
04/01/2025CompleteFLOW STATE ELECTRIC, LLCGeneral Wiring
07/01/2024CompleteFLOW STATE ELECTRIC, LLCGeneral Wiring
1 project · most recent 03/25/2025
FiledStatusContractorScope
03/25/2025Signed-offMORELL BUILDERS INC1 scope_items
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
04/10/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/20/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/03/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/25/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
10/17/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/17/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/17/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 67
DateRequirementInspectorRole
04/01/2025Fenestration areasCALVIN TRANenergy_progress
04/01/2025Permanent certificateCALVIN TRANenergy_progress
04/01/2025Insulation placement and R valuesCALVIN TRANenergy_progress
04/01/2025Fenestration air leakageCALVIN TRANenergy_progress
04/01/2025MeteringCALVIN TRANenergy_progress
04/01/2025Lighting in dwelling unitsCALVIN TRANenergy_progress
04/01/2025Fenestration and door U-factor and product ratingsCALVIN TRANenergy_progress
04/01/2025Air barrier - visual inspectionCALVIN TRANenergy_progress
04/01/2025Fire-Resistant Penetrations and JointsDanny Chenspecial
04/01/2025Structural Stability – Alterations of existing buildingsDanny Chenspecial
04/01/2025Fire-Resistance Rated ConstructionCALVIN TRANprogress
04/01/2025FinalCALVIN TRANprogress
04/01/2025Structural Wood FrameCALVIN TRANprogress
03/25/2025Fire-Resistant Penetrations and JointsDanny Chenspecial
03/25/2025Air barrier - visual inspectionCALVIN TRANenergy_progress
03/25/2025Fenestration air leakageCALVIN TRANenergy_progress
03/25/2025Fenestration and door U-factor and product ratingsCALVIN TRANenergy_progress
03/25/2025Lighting in dwelling unitsCALVIN TRANenergy_progress
03/25/2025Fenestration areasCALVIN TRANenergy_progress
03/25/2025Permanent certificateCALVIN TRANenergy_progress
03/25/2025Insulation placement and R valuesCALVIN TRANenergy_progress
03/25/2025MeteringCALVIN TRANenergy_progress
03/25/2025Structural Wood FrameCALVIN TRANprogress
03/25/2025Fire-Resistance Rated ConstructionCALVIN TRANprogress
03/25/2025FinalCALVIN TRANprogress
Latest 25 of 67.
▾Documents — 62 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/24/2026B01080231-I1Request digital key ↗
08/22/2026B01043133-P4Request digital key ↗
08/22/2026B01043133-P2Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits8
▸DOB NOWLPC Approval/Permit8
08/13/2026B01043133-P4Open ↗
08/13/2026B01080231-I1Open ↗
08/13/2026B01043133-S1Open ↗
Showing 3 of 8 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZoning Exhibit form (1-5)3
08/13/2026B01043133-I1Open ↗
08/13/2026B01043133-P5Open ↗
08/13/2026B01043133-P2Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B01043133-I1Open ↗
▸Seals & Professional Certifications27
▸DOB NOWProgress Inspector Seal & Signature14
09/01/2026B01043133-S1Open ↗
09/01/2026B01043133-S1Open ↗
08/25/2026B01043133-P2Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/22/2026B01043133-P4Open ↗
08/22/2026B01043133-P2Open ↗
08/22/2026B01043133-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/25/2026B01043133-P2Open ↗
08/25/2026B01043133-S2Open ↗
08/24/2026B01043133-I1Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/13/2026B01043133-I1Open ↗
08/13/2026B01043133-P2Open ↗
08/13/2026B01043133-P5Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/22/2026B01043133-P4Open ↗
08/22/2026B01043133-P2Open ↗
08/22/2026B01043133-P5Open ↗
Showing 3 of 8 on file for this type
▸Other Documents4
▸DOB NOWProperty Ownership Certification3
08/22/2026B01043133-P5Open ↗
08/22/2026B01043133-I1Open ↗
08/22/2026B01043133-P2Open ↗
▸DOB NOWFinal Survey1
08/13/2026B01043133-I1Open ↗