← Back
STATEN ISLAND
24 MASSACHUSETTS STREET
STATEN ISLAND · BIN 5175084
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Flood zone X
Locations of Work
ArchitectureStructural
Floor 216p · 1 filing · 20 docs
Floor 115p · 1 filing · 20 docs
Cellar15p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SURFSIDE DEVELOPMENT2307/08/2026
SURF SIDE PROPERTIES603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TONY SAYAD ARCHITECT710/11/2024
A TECH ENGINEERING NYC, PLLC.202/14/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SURF SIDE PROPERTIES INCGeneral Contractor507/08/2026
CAPITAL CONTR P&H CORPPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738410/11/2024
Building Lifecycle
All (65)Filed (9)Permit Issued (7)Signed Off (4)Inspection (13)Objection (2)Special Inspection (30)
10/11/2024
Filed — New Building
PROPOSED NEW 2-STORY & CELLAR ONE-FAMILY DETACHED RESIDENCE WITH ACCESSORY OFF-STREET PARKING FOR 2 CARS
S00602121-P4
10/11/2024
Special inspection requirement — Electric vehicle service equipment requirements
anthony santoro
10/11/2024
Special inspection requirement — Air barrier — testing
anthony santoro
10/11/2024
Special inspection requirement — Final
anthony santoro
10/11/2024
Special inspection requirement — Duct leakage testing, insulation and design
anthony santoro
10/11/2024
Special inspection requirement — Fenestration air leakage
anthony santoro
10/11/2024
Special inspection requirement — Ventilation and air distribution system
anthony santoro
10/11/2024
Special inspection requirement — Subgrade Inspections
anthony santoro
10/11/2024
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
10/11/2024
Special inspection requirement — Structural Wood Frame
anthony santoro
10/11/2024
Special inspection requirement — Maintenance information
anthony santoro
10/11/2024
Special inspection requirement — Permanent certificate
anthony santoro
10/11/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
anthony santoro
10/11/2024
Special inspection requirement — HVAC-R and service water heating system controls
anthony santoro
10/11/2024
Special inspection requirement — Fenestration areas
anthony santoro
10/11/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
10/11/2024
Special inspection requirement — Mechanical Systems
anthony santoro
10/11/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
anthony santoro
10/11/2024
Special inspection requirement — Wood – Prefabricated I-Joists
anthony santoro
10/11/2024
Special inspection requirement — Fire-Resistance Rated Construction
anthony santoro
10/11/2024
Special inspection requirement — Footing and Foundation
anthony santoro
10/11/2024
Special inspection requirement — HVAC-R and service water heating equipment
anthony santoro
10/11/2024
Special inspection requirement — Fireplaces
anthony santoro
10/11/2024
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
anthony santoro
10/11/2024
Special inspection requirement — Insulation placement and R values
anthony santoro
10/11/2024
Special inspection requirement — Air barrier - visual inspection
anthony santoro
10/11/2024
Special inspection requirement — Interior lighting power
anthony santoro
10/11/2024
Special inspection requirement — Concrete - Cast-In-Place
anthony santoro
10/11/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
anthony santoro
09/27/2024
Signed off — New Building
PROPOSED NEW 2-STORY & CELLAR ONE-FAMILY DETACHED RESIDENCE WITH ACCESSORY OFF-STREET PARKING FOR 2 CARS
S00602121-S2
09/25/2024
Signed off — Alteration
INSTALLATION OF NEW FIRE SPRINKLER SYSTEM WITH VALVES AND METER FOR SAME.
S00617909-I1
09/05/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/28/2024
Signed off — New Building
PROPOSED NEW 2-STORY & CELLAR ONE-FAMILY DETACHED RESIDENCE WITH ACCESSORY OFF-STREET PARKING FOR 2 CARS
S00602121-S1
08/27/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/27/2024
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
08/23/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/23/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/23/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/12/2024
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
08/09/2024
Permit issued — Curb Cut
S00602121-S1-CC
08/07/2024
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
08/06/2024
Signed off — Alteration
PROP. 8 FT. HIGH CHAIN LINK FENCE & ACCESS GATES ALONG PROPERTY LINES, PURSUANT TO BC 3307.7 & BUILDING BULLETIN 2009-2010 IN CONJUNCTION WITH A NEW ONE-FAMILY BUILDING TO BE CONSTRUCTED ON THIS LOT.
S00616256-I1
08/06/2024
Special inspection requirement — Interior lighting power
anthony santoro
08/06/2024
Special inspection requirement — Final
anthony santoro
08/05/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/23/2024
Filed — New Building
PROPOSED NEW 2-STORY & CELLAR ONE-FAMILY DETACHED RESIDENCE WITH ACCESSORY OFF-STREET PARKING FOR 2 CARS
S00602121-P2
07/23/2024
Filed — New Building
PROPOSED NEW 2-STORY & CELLAR ONE-FAMILY DETACHED RESIDENCE WITH ACCESSORY OFF-STREET PARKING FOR 2 CARS
S00602121-P3
04/18/2024
Permit issued — Construction Fence
S00616256-I1-FN
04/18/2024
Permit issued — Foundation
S00602121-I1-GC-CX
02/20/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/20/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/14/2024
Filed — Alteration
INSTALLATION OF NEW FIRE SPRINKLER SYSTEM WITH VALVES AND METER FOR SAME.
S00617909-P1
12/07/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/01/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
11/28/2023
Permit issued — Plumbing
S00617909-I1-PL
11/27/2023
Permit issued — Plumbing
S00602121-S2-PL
04/12/2023
Permit issued — Construction Fence
S00616256-I1-FN
04/12/2023
Permit issued — General Construction
S00602121-I1-GC-CX
01/07/2022
Filed — Alteration
INSTALLATION OF NEW FIRE SPRINKLER SYSTEM WITH VALVES AND METER FOR SAME.
S00617909-I1
12/06/2021
Objection raised — Scope
Latest 60 of 65 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offSURF SIDE PROPERTIES INC08/09/2024
DOB NOWConstruction FenceSigned-offSURF SIDE PROPERTIES INC04/18/2024
DOB NOWFoundationPermit IssuedSURF SIDE PROPERTIES INC04/18/2024
DOB NOWPlumbingSigned-offCAPITAL CONTR P&H CORP11/28/2023
DOB NOWPlumbingSigned-offCAPITAL CONTR P&H CORP11/27/2023
DOB NOWConstruction FenceSigned-offSURF SIDE PROPERTIES INC04/12/2023
DOB NOWGeneral ConstructionPermit IssuedSURF SIDE PROPERTIES INC04/12/2023
1 project · most recent 10/11/2024
Air Conditioning Systems Associated Ducts and Piping Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/11/2024Signed-offSURF SIDE PROPERTIES INCAir Conditioning Systems, Associated Ducts and Piping, Heating Systems, Ventilation Systems
Cooling
York YORK (AIR HANDLER) JHETB36DBCS2N1A; YORK (AIR HANDLER) JHETB24CBAS2N1A, YORK (CONDENSER) TCD2B36S21SA; YORK (CONDENSER) TCD2B24S21A 36,000 BTU · Condensing Unit ×2
Heating
Triangle Tube INSTINCT SOLO 110 110,000 BTU · Boiler ×1
Ventilation
Panasonic FV-10VE2 80 CFM · Erv ×1
Ducts & Piping
Southwark Metal G-60 COATED GALVANIZED STEEL 24 GA. Ductwork ×1
1 project · most recent 10/11/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
10/11/2024Signed-offCAPITAL CONTR P&H CORPGas, Storm, Water/Sanitary
1 project · most recent 02/06/2024
General Wiring
FiledStatusContractorScope
02/06/2024CompleteD AND H ELECTRICAL CONSTGeneral Wiring
1 project · most recent 10/11/2024
Wood
FiledStatusContractorScope
10/11/2024Signed-offSURF SIDE PROPERTIES INCWood
1 project · most recent 10/11/2024
Earthwork
FiledStatusContractorScope
10/11/2024Signed-offSURF SIDE PROPERTIES INCEarthwork
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
09/05/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/27/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/27/2024Pass-Final Curb Cut Non-Directive 14PassView ↗
08/23/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/23/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/23/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
08/12/2024Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
08/07/2024Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
08/05/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/20/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/20/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/07/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/01/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 62
DateRequirementInspectorRole
10/11/2024HVAC-R and service water heating system controlsanthony santoroenergy_progress
10/11/2024Fenestration and door U-factor and product ratingsanthony santoroenergy_progress
10/11/2024Fenestration air leakageanthony santoroenergy_progress
10/11/2024HVAC-R and service water piping design and insulationanthony santoroenergy_progress
10/11/2024Ventilation and air distribution systemanthony santoroenergy_progress
10/11/2024Fenestration areasanthony santoroenergy_progress
10/11/2024Concrete - Cast-In-Placeanthony santorospecial
10/11/2024Exterior Insulation and Finish Systems (EIFS)anthony santorospecial
10/11/2024Fire-Resistant Penetrations and Jointsanthony santorospecial
10/11/2024Mechanical Systemsanthony santorospecial
10/11/2024Subgrade Inspectionsanthony santorospecial
10/11/2024Subsurface Investigations (Borings/Test Pits)anthony santorospecial
10/11/2024Wood – Prefabricated I-Joistsanthony santorospecial
10/11/2024Energy Code Compliance Inspectionsanthony santoroprogress
10/11/2024Finalanthony santoroprogress
10/11/2024Fire-Resistance Rated Constructionanthony santoroprogress
10/11/2024Footing and Foundationanthony santoroprogress
10/11/2024Structural Wood Frameanthony santoroprogress
10/11/2024HVAC-R and service water heating equipmentanthony santoroenergy_progress
10/11/2024Fireplacesanthony santoroenergy_progress
10/11/2024Maintenance informationanthony santoroenergy_progress
10/11/2024Duct leakage testing, insulation and designanthony santoroenergy_progress
10/11/2024Electric vehicle service equipment requirementsanthony santoroenergy_progress
10/11/2024Insulation placement and R valuesanthony santoroenergy_progress
10/11/2024Permanent certificateanthony santoroenergy_progress
Latest 25 of 62.
▾Documents — 86 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/25/2026S00602121-S2Request digital key ↗
08/25/2026S00602121-S1Request digital key ↗
08/25/2026S00602121-P3Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION3
01/10/2024540203858Open ↗
01/04/2024540203858Open ↗
07/28/2021540203858Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation2
01/24/2024540203858Open ↗
08/26/2021540203858Open ↗
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026S00602121-P4Open ↗
08/13/2026S00602121-P2Open ↗
08/13/2026S00602121-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)3
08/13/2026S00602121-I1Open ↗
08/13/2026S00602121-P4Open ↗
08/13/2026S00602121-P2Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00602121-I1Open ↗
▸Seals & Professional Certifications32
▸DOB NOWProgress Inspector Seal & Signature14
08/28/2026S00602121-S2Open ↗
08/28/2026S00602121-S2Open ↗
08/28/2026S00602121-S2Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/25/2026S00602121-P4Open ↗
08/25/2026S00602121-I1Open ↗
08/25/2026S00602121-S1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
08/28/2026S00602121-S2Open ↗
08/28/2026S00602121-P4Open ↗
08/28/2026S00602121-P4Open ↗
Showing 3 of 7 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
07/28/2021540203858Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/28/2021540203858Open ↗
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/13/2026S00602121-I1Open ↗
08/13/2026S00602121-P2Open ↗
08/13/2026S00602121-P4Open ↗
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist3
08/25/2026S00602121-P2Open ↗
08/25/2026S00602121-P4Open ↗
08/14/2026S00602121-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026S00602121-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026S00602121-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026S00602121-I1Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026S00602121-S2Open ↗
08/13/2026S00602121-I1Open ↗
▸Inspections & Test Reports7
▸DOB NOWSOIL REPORT3
08/13/2026S00602121-I1Open ↗
08/13/2026S00602121-P2Open ↗
08/13/2026S00602121-P4Open ↗
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
07/28/2021540203858Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/28/2021540203858Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026S00602121-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026S00602121-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
08/26/2021540203858Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
07/28/2021540203858Open ↗
▸BISADDITIONAL INFORMATION1
01/24/2024540203858Open ↗
▸Other Documents12
▸DOB NOWSite Survey: Initial3
08/13/2026S00602121-P2Open ↗
08/13/2026S00602121-P4Open ↗
08/13/2026S00602121-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026S00602121-P4Open ↗
08/13/2026S00602121-P2Open ↗
08/13/2026S00602121-I1Open ↗
▸DOB NOWProperty Ownership Certification3
08/25/2026S00602121-P2Open ↗
08/25/2026S00602121-P4Open ↗
08/14/2026S00602121-I1Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION2
01/24/2024540203858Open ↗
07/28/2021540203858Open ↗
▸DOB NOWFinal Survey1
08/13/2026S00602121-I1Open ↗