← Back
BuildNYC
One story - permanent living quarter
240-02 147TH ROAD
QUEENS · BIN 4291652
💬 Discuss this project
1950Year Built
2Stories
A2Building Class
R3XZoning
2,889 sfGross Floor Area
1Units
One story - permanent living quarter · Owner of record: 245-40 147 Ave · 4,000 sf lot · 0.72 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofVertical and Horizontal Enlargement. Conversion to Two-famil3p · 1 filing · 20 docs
AtticVertical and Horizontal Enlargement. Conversion to Two-famil18p · 1 filing · 20 docs
Floor 2Vertical and Horizontal Enlargement. Conversion to Two-famil18p · 1 filing · 20 docs
Floor 1Vertical and Horizontal Enlargement. Conversion to Two-famil18p · 1 filing · 20 docs
CellarVertical and Horizontal Enlargement. Conversion to Two-famil20p · 1 filing · 20 docs
Site & exteriorSide yard fence construction14p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/10/2026$1.6M—245-40 147 AVE LLC → Private party$554/sf building
06/28/2024$570K—Private party → 245-40 147 AVE LLC$197/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
D&E Build Evergreen810/17/2025
Peter Cho Architects108/12/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Metro Design1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Hayden Brown ConstructionGeneral Contractor507/08/2026
Hayden Brown ConstructionScaffold304/09/2026
Ayyub ElectricElectrical103/22/2026
Infiniti Esc PlumbingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
D&E Build Evergreen I9342810/17/2025
Triangle Inspection & Tes7495310/16/2025
Building Lifecycle
All (81)Filed (9)Permit Issued (6)Signed Off (3)Inspection (5)Objection (28)Special Inspection (30)
12/16/2025
Signed off — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING (COQ 86567) INTO A TWO- STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTIVAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY
Q01090037-S1
11/28/2025
Signed off — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING (COQ 86567) INTO A TWO- STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTIVAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY
Q01090037-S2
11/26/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/22/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Danny Chen
11/22/2025
Special inspection requirement — Maintenance information
Danny Chen
11/22/2025
Special inspection requirement — Duct leakage testing, insulation and design
Danny Chen
11/22/2025
Special inspection requirement — Mechanical Systems
Danny Chen
11/22/2025
Special inspection requirement — Final
PETER CHO
11/22/2025
Special inspection requirement — Energy Code Compliance Inspections
Danny Chen
11/22/2025
Special inspection requirement — HVAC-R and service water heating system controls
Danny Chen
11/22/2025
Special inspection requirement — HVAC-R and service water heating equipment
Danny Chen
11/22/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Danny Chen
11/22/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Danny Chen
11/22/2025
Special inspection requirement — Ventilation and air distribution system
Danny Chen
11/17/2025
Objection resolved — Addressed
11/11/2025
Signed off — Alteration
Q01094518-I1
11/11/2025
Special inspection requirement — Fenestration air leakage
Danny Chen
11/11/2025
Special inspection requirement — Air barrier - visual inspection
Danny Chen
11/11/2025
Special inspection requirement — Metering
Danny Chen
11/11/2025
Special inspection requirement — Final
PETER CHO
11/11/2025
Special inspection requirement — Structural Steel - High Strength Bolting
Danny Chen
11/11/2025
Special inspection requirement — Interior lighting power
Danny Chen
11/11/2025
Special inspection requirement — Maintenance information
Danny Chen
11/11/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
11/11/2025
Special inspection requirement — Permanent certificate
Danny Chen
11/11/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Danny Chen
11/11/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Danny Chen
11/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Danny Chen
11/11/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Danny Chen
11/11/2025
Special inspection requirement — Concrete - Cast-In-Place
Danny Chen
11/11/2025
Special inspection requirement — Subgrade Inspections
Danny Chen
11/11/2025
Special inspection requirement — Structural Steel - Details
Danny Chen
11/11/2025
Special inspection requirement — Structural Wood Frame
Danny Chen
11/11/2025
Special inspection requirement — Footing and Foundation
Danny Chen
11/11/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Danny Chen
11/06/2025
Objection raised — Energy
10/17/2025
Filed — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING (COQ 86567) INTO A TWO- STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTIVAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY
Q01090037-P3
10/16/2025
Filed — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING (COQ 86567) INTO A TWO- STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTIVAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY
Q01090037-P5
10/16/2025
Filed — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING (COQ 86567) INTO A TWO- STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTIVAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY
Q01090037-P4
07/23/2025
Permit issued — Construction Fence
Q01094518-I1-FN
07/21/2025
Permit issued — General Construction
Q01090037-I1-GC-CX
05/21/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/21/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
05/21/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/19/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/14/2025
Permit issued — Plumbing
Q01090037-S1-PL
02/21/2025
Filed — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING (COQ 86567) INTO A TWO- STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTIVAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY
Q01090037-P2
02/04/2025
Filed — Alteration CO
CONVERSION OF THE EXISTING ONE AND HALF STORY ONE-FAMILY BUILDING (COQ 86567) INTO A TWO- STORY TWO-FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED VERTIVAL AND HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY
Q01090037-P1
01/29/2025
Permit issued — General Construction
Q01090037-I1-GC-CX
01/29/2025
Permit issued — Mechanical Systems
Q01090037-S2-MS
12/12/2024
Objection resolved — Addressed
12/05/2024
Objection resolved — Addressed
12/02/2024
Objection raised — Other
12/02/2024
Objection raised — Other
11/25/2024
Permit issued — Construction Fence
Q01094518-I1-FN
11/25/2024
Objection resolved — Addressed
11/14/2024
Objection resolved — Addressed
11/08/2024
Objection resolved — Addressed
11/08/2024
Objection resolved — Addressed
11/08/2024
Objection resolved — Addressed
Latest 60 of 81 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FenceSigned-offHayden Brown Cons07/23/2025
DOB NOWGeneral ConstructionPermit IssuedHayden Brown Cons07/21/2025
DOB NOWPlumbingSigned-offInfiniti Esc Plumbing05/14/2025
DOB NOWGeneral ConstructionPermit IssuedHayden Brown Cons01/29/2025
DOB NOWMechanical SystemsSigned-offHayden Brown Cons01/29/2025
DOB NOWConstruction FenceSigned-offHayden Brown Cons11/25/2024
1 project · most recent 10/17/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/17/2025Permit IssuedHayden Brown ConsAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Goodman GLXS3BN3610AA 36,000 BTU · Condensing Unit ×2
GLXS3BN6010AA 60,000 BTU · Condensing Unit ×2
Heating
Goodman GR9S800603BNAA 60,000 BTU · Furnace ×2
GR9S921005CNAA 100,000 BTU · Furnace ×2
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×10
Delta Breeze SMT150 150 CFM · Exhaust Fan ×4
1 project · most recent 10/17/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
10/17/2025Signed-offInfiniti Esc PlumbingGas, Storm, Water/Sanitary
2 projects · most recent 03/15/2025
General Wiring
FiledStatusContractorScope
03/15/2025CompleteAyyub Electric—
03/15/2025CompleteAyyub ElectricGeneral Wiring
1 project · most recent 10/17/2025
Steel Wood
FiledStatusContractorScope
10/17/2025Permit IssuedHayden Brown ConsSteel, Wood
1 project · most recent 10/17/2025
Earthwork
FiledStatusContractorScope
10/17/2025Permit IssuedHayden Brown ConsEarthwork
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
11/26/2025Pass-Final CND-Occupancy InspectionPassView ↗
05/21/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/21/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
05/21/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/19/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 113
DateRequirementInspectorRole
11/22/2025Mechanical SystemsDanny Chenspecial
11/22/2025Structural Stability – Alterations of existing buildingsDanny Chenspecial
11/22/2025Fire-Resistant Penetrations and JointsDanny Chenspecial
11/22/2025HVAC-R and service water piping design and insulationDanny Chenenergy_progress
11/22/2025Duct leakage testing, insulation and designDanny Chenenergy_progress
11/22/2025HVAC-R and service water heating equipmentDanny Chenenergy_progress
11/22/2025Ventilation and air distribution systemDanny Chenenergy_progress
11/22/2025Maintenance informationDanny Chenenergy_progress
11/22/2025HVAC-R and service water heating system controlsDanny Chenenergy_progress
11/22/2025FinalPETER CHOprogress
11/22/2025Energy Code Compliance InspectionsDanny Chenprogress
11/11/2025Electric vehicle service equipment requirementsDanny Chenenergy_progress
11/11/2025Insulation placement and R valuesDanny Chenenergy_progress
11/11/2025Permanent certificateDanny Chenenergy_progress
11/11/2025Excavations - Sheeting, Shoring, and BracingDanny Chenspecial
11/11/2025Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
11/11/2025Structural Stability – Alterations of existing buildingsDanny Chenspecial
11/11/2025MasonryDanny Chenspecial
11/11/2025Fire-Resistant Penetrations and JointsDanny Chenspecial
11/11/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationDanny Chenspecial
11/11/2025Structural Steel - High Strength BoltingDanny Chenspecial
11/11/2025Concrete - Cast-In-PlaceDanny Chenspecial
11/11/2025Subgrade InspectionsDanny Chenspecial
11/11/2025Structural Steel - DetailsDanny Chenspecial
11/11/2025Footing and FoundationDanny Chenprogress
Latest 25 of 113.
▾Documents — 84 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/21/2026Q01094518-I1Request digital key ↗
08/20/2026Q01090037-P4Request digital key ↗
08/20/2026Q01090037-P3Request digital key ↗
Showing 3 of 9 on file for this type
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026Q01090037-I1Open ↗
08/13/2026Q01090037-P1Open ↗
08/13/2026Q01090037-P3Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp3
08/13/2026Q01090037-I1Open ↗
08/13/2026Q01090037-P3Open ↗
08/13/2026Q01090037-P1Open ↗
▸Seals & Professional Certifications40
▸DOB NOWProgress Inspector Seal & Signature19
09/23/2026Q01090037-S2Open ↗
09/23/2026Q01090037-S2Open ↗
09/23/2026Q01090037-S2Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/23/2026Q01090037-S2Open ↗
09/22/2026Q01090037-P5Open ↗
09/01/2026Q01090037-S1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/21/2026Q01094518-I1Open ↗
08/20/2026Q01090037-P3Open ↗
08/20/2026Q01090037-P5Open ↗
Showing 3 of 9 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/13/2026Q01090037-P3Open ↗
08/13/2026Q01090037-I1Open ↗
08/13/2026Q01090037-P1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/20/2026Q01090037-P4Open ↗
08/20/2026Q01090037-P3Open ↗
08/20/2026Q01090037-P2Open ↗
Showing 3 of 8 on file for this type
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT3
08/13/2026Q01090037-I1Open ↗
08/13/2026Q01090037-P3Open ↗
08/13/2026Q01090037-P1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01090037-I1Open ↗
▸Other Documents14
▸DOB NOWSite Survey: Initial3
08/13/2026Q01090037-P1Open ↗
08/13/2026Q01090037-I1Open ↗
08/13/2026Q01090037-P3Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026Q01090037-P1Open ↗
08/13/2026Q01090037-P3Open ↗
08/13/2026Q01090037-I1Open ↗
▸DOB NOWPlot Diagram3
08/13/2026Q01090037-P1Open ↗
08/13/2026Q01090037-P3Open ↗
08/13/2026Q01090037-I1Open ↗
▸DOB NOWProperty Ownership Certification3
08/20/2026Q01090037-P3Open ↗
08/20/2026Q01090037-P1Open ↗
08/20/2026Q01090037-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q01090037-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q01090037-I1Open ↗