← Back
Two family converted from one family
240 GREENE AVENUE
BROOKLYN · BIN 3056258
💬 Discuss this project
1899Year Built
2Stories
B3Building Class
R6BZoning
1,638 sfGross Floor Area
2Units
1 Open Violation ▸
Two family converted from one family · Owner of record: 240 GREENE PARTNERS LLC · 1,350 sf lot · 1.21 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 34p · 1 filing · 15 docs
Floor 27p · 1 filing · 15 docs
Floor 14p · 1 filing · 15 docs
Cellar6p · 1 filing · 15 docs
Sub-Basement3p · 1 filing · 15 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/27/2024$75K—GREENE MANAGEMENT PLUS LLC → GREENE 240 PROJECT LLC$46/sf building
02/27/2024$1.2M—GREENE 240 PROJECT LLC → 240 GREENE PARTNERS LLC$720/sf building
04/20/2023$1.1M—Private party → GREENE 240 PROJECT LLC$664/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHUN ENGINEERING CONSULTANT PLLC310/16/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CAVALRY LLC303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CAVALRY LLCGeneral Contractor203/21/2026
GLENNS PLUMBING SVCS INCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHUN ENGINEERING CONSULTA9605310/16/2024
Building Lifecycle
All (20)Filed (3)Permit Issued (2)Violation (1)Special Inspection (14)
05/28/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/27/2025
Permit issued — Plumbing
B01067740-S2-PL
11/01/2024
Permit issued — Mechanical Systems
B01067740-S1-MS
10/16/2024
Filed — Alteration
Mechanical filed in conjunction with B01067740-I1. No change in use, egress or occupancy.
B01067740-S1
10/16/2024
Filed — Alteration
Mechanical filed in conjunction with B01067740-I1. No change in use, egress or occupancy.
B01067740-S2
10/15/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
JAMES CHUN
10/15/2024
Special inspection requirement — HVAC-R and service water heating equipment
JAMES CHUN
10/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JAMES CHUN
10/15/2024
Special inspection requirement — Energy Code Compliance Inspections
JAMES CHUN
10/15/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
JAMES CHUN
10/15/2024
Special inspection requirement — Maintenance information
JAMES CHUN
10/15/2024
Special inspection requirement — HVAC-R and service water heating system controls
JAMES CHUN
10/15/2024
Special inspection requirement — HVAC-R and service water heating equipment
JAMES CHUN
10/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JAMES CHUN
10/15/2024
Special inspection requirement — Energy Code Compliance Inspections
JAMES CHUN
10/15/2024
Special inspection requirement — Maintenance information
JAMES CHUN
10/15/2024
Special inspection requirement — HVAC-R and service water heating system controls
JAMES CHUN
07/02/2024
Filed — Alteration
Mechanical filed in conjunction with B01067740-I1. No change in use, egress or occupancy.
B01067740-I1
06/20/2024
Special inspection requirement — Mechanical Systems
JAMES CHUN
06/20/2024
Special inspection requirement — Final
JAMES CHUN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedGLENNS PLUMBING SVCS INC02/27/2025
DOB NOWMechanical SystemsPermit IssuedCAVALRY LLC11/01/2024
BISPLISSUEDTHE PLUMBING COMPANY03/23/2006
BISPLISSUEDPAUL COMMDORE & SONS LTD01/22/2001
BIS—RE-ISSUEDLIGHTHOUSE CONSTRUCTION12/21/2000
1 project · most recent 10/16/2024
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
10/16/2024Permit IssuedCAVALRY LLCHeating and Air Conditioning Systems
Heat / Cool
Daikin 4MXS36RMVJU 36,000 BTU · Fan Coil Indoor ×4
1 project · most recent 10/16/2024
Gas Water/Sanitary
FiledStatusContractorScope
10/16/2024Permit IssuedGLENNS PLUMBING SVCS INCGas, Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
10/15/2024HVAC-R and service water piping design and insulationJAMES CHUNenergy_progress
10/15/2024HVAC-R and service water heating equipmentJAMES CHUNenergy_progress
10/15/2024Fire-Resistant Penetrations and JointsJAMES CHUNspecial
10/15/2024Energy Code Compliance InspectionsJAMES CHUNprogress
10/15/2024HVAC-R and service water piping design and insulationJAMES CHUNenergy_progress
10/15/2024Maintenance informationJAMES CHUNenergy_progress
10/15/2024HVAC-R and service water heating system controlsJAMES CHUNenergy_progress
10/15/2024HVAC-R and service water heating equipmentJAMES CHUNenergy_progress
10/15/2024Fire-Resistant Penetrations and JointsJAMES CHUNspecial
10/15/2024Energy Code Compliance InspectionsJAMES CHUNprogress
10/15/2024Maintenance informationJAMES CHUNenergy_progress
10/15/2024HVAC-R and service water heating system controlsJAMES CHUNenergy_progress
06/20/2024Mechanical SystemsJAMES CHUNspecial
06/20/2024FinalJAMES CHUNprogress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026B01067740-S2Request digital key ↗
08/23/2026B01067740-S1Request digital key ↗
08/23/2026B01067740-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026B01067740-S2Open ↗
09/01/2026B01067740-S2Open ↗
08/24/2026B01067740-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026B01067740-S2Open ↗
08/13/2026B01067740-S1Open ↗
08/13/2026B01067740-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B01067740-S2Open ↗
08/24/2026B01067740-S1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026B01067740-I1Open ↗
08/13/2026B01067740-S1Open ↗
08/13/2026B01067740-S2Open ↗