← Back
Predominantly retail with other uses
2400 HOFFMAN STREET
BRONX · BIN 2011907
💬 Discuss this project
1931Year Built
2Stories
K4Building Class
R6Zoning
8,125 sfGross Floor Area
8Units
0 Open Violations
Predominantly retail with other uses · Owner of record: 571-585 E 187TH STREET · 3,242 sf lot · 2.51 FAR built · Flood zone X
Locations of Work
Mechanical
Roof2p · 2 filings · 10 docs
Floor 11p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LORDAE MANAGEMENT507/08/2026
CSC OF NY INC103/21/2026
CSC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASHRAF CORP110/19/2023
TSF ENGINEERING, PC107/12/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MA DESIGNS NYC103/21/2026
W J PROFESSIONAL EXPEDITING COMPANY203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MEDRA EXHAUST SYSTEMS CORGeneral Contractor107/08/2026
INTEGRA PLUMBING OF N.YPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JAY KAVI CORPORATION8500110/19/2023
Building Lifecycle
All (16)Filed (2)Permit Issued (2)Violation (1)Inspection (1)Objection (6)Special Inspection (4)
12/21/2023
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
10/27/2023
Permit issued — Mechanical Systems
X00945382-I1-MS
10/19/2023
Filed — Alteration
MODIFY EXISTING HOOD, DUCT, AND EXHAUST FAN AS PER PLAN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X00945382-I1
10/09/2023
Special inspection requirement — Mechanical Systems
Jay Kavi
10/09/2023
Special inspection requirement — Final
BRIAN MCCAFFREY
08/28/2023
Permit issued — Boiler Equipment
X00879475-I1-BE
07/20/2023
Objection resolved — Addressed
07/20/2023
Objection resolved — Addressed
07/20/2023
Objection resolved — Addressed
07/14/2023
Objection raised — Fire_Protection
07/14/2023
Objection raised — Fire_Protection
07/14/2023
Objection raised — Fire_Protection
07/12/2023
Filed — Alteration
FILING FOR THE INSTALLATION OF GAS FIRED BOILER ON 2ND FLOOR BOILER ROOM AS PER PLANS FILED HEREWITH. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
X00879475-I1
06/09/2023
Special inspection requirement — HVAC-R and service water heating system controls
Nicholas Tucci
06/09/2023
Special inspection requirement — HVAC-R and service water heating equipment
Nicholas Tucci
05/17/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedMEDRA EXHAUST SYSTEMS COR10/27/2023
DOB NOWBoiler EquipmentSigned-offINTEGRA PLUMBING OF N.Y08/28/2023
BISEQISSUEDCSC OF NY INC09/18/2014
BISFPISSUEDMASTER FIRE PREVENTION SYSTEMS09/22/1995
BISMHISSUEDMASTER FIRE PREVENTION SYSTEM09/07/1995
BISPLISSUEDAMOK INC07/27/1990
BISFPISSUEDMASTER FIRE PREVENTION SYSTEN04/05/1990
1 project · most recent 12/04/2023
General Wiring
FiledStatusContractorScope
12/04/2023Permit IssuedTIMOTHY COLEMAN LICENSEDGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
12/21/2023Pass-Final Boiler Equipment InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
10/09/2023Mechanical SystemsJay Kavispecial
10/09/2023FinalBRIAN MCCAFFREYprogress
06/09/2023HVAC-R and service water heating system controlsNicholas Tuccienergy_progress
06/09/2023HVAC-R and service water heating equipmentNicholas Tuccienergy_progress
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/23/2026X00879475-I1Request digital key ↗
08/22/2026X00945382-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
09/17/2014240072960Open ↗
▸BISWORK PERMIT APPLICATION1
09/17/2014240072960Open ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature3
09/23/2026X00879475-I1Open ↗
09/23/2026X00879475-I1Open ↗
08/27/2026X00945382-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
07/01/2015240072960Open ↗
07/01/2015240072960Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/23/2026X00879475-I1Open ↗
08/22/2026X00945382-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
09/17/2014240072960Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/17/2014240072960Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/17/2014240072960Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026X00945382-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/23/2026X00879475-I1Open ↗
08/22/2026X00945382-I1Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/17/2014240072960Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/01/2015240072960Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
07/01/2015240072960Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
09/17/2014240072960Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
09/17/2014240072960Open ↗