| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 12/09/2024 | $1.3M | — | — → Private party | $595/sf building |
| 08/21/2023 | $550K | — | — → — | $259/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| BADALY ENGINEERING PLLC | 5 | 08/07/2024 |
| DUCTILE LLC | 1 | 03/25/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| R H DRUMMOND EXP | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| MOKEN HOME IMPROVEMENT | General Contractor | 5 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| BADALY ARCHITECT PLLC | 7137 | 3 | 10/25/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Construction Fence | Signed-off | MOKEN HOME IMPROVEMENT | 03/27/2024 |
| DOB NOW | General Construction | Permit Issued | MOKEN HOME IMPROVEMENT | 02/21/2024 |
| DOB NOW | General Construction | Permit Issued | MOKEN HOME IMPROVEMENT | 01/22/2024 |
| DOB NOW | General Construction | Permit Issued | MICHELLE MILES REMODELING AND CONST | 09/29/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/07/2024 | Permit Issued | MOKEN HOME IMPROVEMENT | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Gree GREE 4LIV09HP115V1AH 9,000 BTU · Heat Pump Outdoor ×6 GREE 4LIV12HP230V1AH 12,000 BTU · Split System ×2 GREE 4LIV36HP230V1AO 38,500 BTU · Heat Pump Outdoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/07/2024 | — | — | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/14/2024 | Permit Issued | TRINCITY ELECTRIC, INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/07/2024 | Permit Issued | MOKEN HOME IMPROVEMENT | Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/07/2024 | Permit Issued | MOKEN HOME IMPROVEMENT | Fence |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/07/2024 | Fire-Resistant Penetrations and Joints | — | special |
| 08/07/2024 | Energy Code Compliance Inspections | — | progress |
| 08/07/2024 | HVAC-R and service water heating system controls | — | energy_progress |
| 08/07/2024 | HVAC-R and service water heating equipment | — | energy_progress |
| 08/07/2024 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 08/07/2024 | Maintenance information | — | energy_progress |
| 10/20/2023 | Fire-Resistant Penetrations and Joints | SHAHIN BADALY | special |
| 10/20/2023 | Final | SHAHIN BADALY | progress |
| 10/13/2023 | Fire-Resistant Penetrations and Joints | SHAHIN BADALY | special |
| 10/13/2023 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | SHAHIN BADALY | special |
| 10/13/2023 | Structural Stability – Alterations of existing buildings | SHAHIN BADALY | special |
| 10/13/2023 | Energy Code Compliance Inspections | SHAHIN BADALY | progress |
| 10/13/2023 | Fire-Resistance Rated Construction | SHAHIN BADALY | progress |
| 10/13/2023 | Fenestration air leakage | SHAHIN BADALY | energy_progress |
| 10/13/2023 | Insulation placement and R values | SHAHIN BADALY | energy_progress |
| 10/13/2023 | Interior lighting power | SHAHIN BADALY | energy_progress |
| 10/13/2023 | Permanent certificate | SHAHIN BADALY | energy_progress |
| 10/13/2023 | Fenestration areas | SHAHIN BADALY | energy_progress |
| 10/13/2023 | Fenestration and door U-factor and product ratings | SHAHIN BADALY | energy_progress |
| 10/13/2023 | Air barrier - visual inspection | SHAHIN BADALY | energy_progress |