HPD11/01/2025§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES ON FIRE RATED DOOR IN THE ENTRANCE LOCATED AT APT 15B, 15th STORY, 4th APARTMENT FROM NORTH AT EAST
ECB10/24/2024FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMENTING THE CONDITIONS OF PSID#X0002212 BY THE AUGUST 1,2024 DEADLINE.TO DATE,THE DEPARTMENT HAS$12K due
DOB12/01/2022FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
HPD10/21/2022HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 19D, 19th STORY, 2nd APARTMENT FROM SOUTH AT WEST
DOB09/11/2013CYCLE 7 UNSAFE REPORT FILED
ECB06/21/2022TEMP CONST EQUIPMENT ONSITE-EXPIRED PERMIT.ATOI OBSERVED SIDEWALKSHED IN PLACE&SWS PERMIT EXPIRED.PERMIT X00470008 EXPIRED6/18/22.RENEW PERMITNothing owed — awaiting certificate of correction
ECB06/21/2022PEDESTRIAN PROTECTION DOESNT MEET CODE SPECS ATOI OBSERVED SIDEWALKSHED ISNT GOOD CONDITION OBSERVED SWS POLE LEG WOOD BASE PLATE MOTTED,CRACK,&DISPLACE MULTIPLE LOCATION.COMPLY TO CODE SPECSNothing owed — awaiting certificate of correction
ECB03/03/2022FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES.AS NOTED:AT TIME OF INSPECTION OBSERVED AT EXP #3 EAST ELEVATION SPALLING CRACKED BRICK ON 16 FLOOR LINTEL HEIGHT.ROOF CRACKS AND BULGING BRICKS ONNothing owed — awaiting certificate of correction
ECB12/03/2021FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A,8A&9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#908649. AGG1: PRIOR NOV#37019128J UNDERNothing owed — awaiting certificate of correction
ECB03/26/2021PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS:SIDEWALK SHED MAINTAINENCE/CONDITION.AT THE TIME OF MY INSPECTION OF A PROPOSED 20 STORY FACADE ALTERATION I OBSERVED A SIDEWALK SHED IN NEED OF MAINTAINNothing owed — awaiting certificate of correction
ECB09/09/2020FAILURE TO HAVE SITE SAFETY MANAGER OR COORDINATOR PRESENT AT JOBSITE:AT THE TIE OF MY INSPECTION OF A FACADE ALTERATION OF A 20 STORY BUILDING,I OBSERVED 2 MULTIPOINT SUSPENDED SCAFFOLDS IN USE/SUSPENDED AT EXNothing owed — awaiting certificate of correction