← Back
Predominantly retail with other uses
2412 3 AVENUE
BRONX · BIN 2092149
💬 Discuss this project
1931Year Built
3Stories
K4Building Class
M1-2/R6AZoning
4,050 sfGross Floor Area
4Units
Predominantly retail with other uses · Owner of record: ONE BRUCKNER CORNER LLC · 2,696 sf lot · 1.5 FAR built · Flood zone AE
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof7p · 1 filing · 20 docs
Floor 117p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
1 BRUCKNER1203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/22/2021$3.2M—1 BRUCKNER LLC → ONE BRUCKNER CORNER LLC$790/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EP ENGINEERING LLC305/08/2024
MCLAREN ENGINEERING GROUP109/07/2023
SMITH & ARCHITECTS109/02/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PAUL FUSCO CONSULTING1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CORINTHIAN DESIGNS INCGeneral Contractor507/08/2026
ROCK E SMALL PLBG&HTG INCPlumbing307/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
EP INSPECTIONS AND COMMIS7079505/08/2024
Building Lifecycle
All (55)Filed (5)Permit Issued (4)Inspection (2)Objection (14)Special Inspection (30)
09/09/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/05/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/22/2024
Permit issued — Plumbing
X00925357-S2-PL
05/09/2024
Special inspection requirement — Mechanical Systems
Christopher Burgess
05/09/2024
Special inspection requirement — Final
Christopher Burgess
05/09/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Burgess
05/09/2024
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Burgess
05/09/2024
Special inspection requirement — Shutoff dampers
Christopher Burgess
05/09/2024
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Burgess
05/09/2024
Special inspection requirement — Duct leakage testing, insulation and design
Christopher Burgess
05/09/2024
Special inspection requirement — Post-installed Anchors
Christopher Burgess
05/09/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
05/09/2024
Special inspection requirement — Exhaust and Vent Systems in Plenums and Ducts
Christopher Burgess
05/09/2024
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
Christopher Burgess
05/08/2024
Filed — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE HVAC REPLACEMENT AND REPLACEMENT OF ASSOCIATED DUCTWORK. NO CHANGE OF USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
X00925357-P1
04/19/2024
Special inspection requirement — Duct leakage testing, insulation and design
Christopher Burgess
04/19/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Burgess
04/19/2024
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Burgess
04/19/2024
Special inspection requirement — Shutoff dampers
Christopher Burgess
04/19/2024
Special inspection requirement — Mechanical Systems
Christopher Burgess
04/19/2024
Special inspection requirement — Post-installed Anchors
Christopher Burgess
04/19/2024
Special inspection requirement — Final
Christopher Burgess
04/19/2024
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Burgess
04/19/2024
Special inspection requirement — Exhaust and Vent Systems in Plenums and Ducts
Christopher Burgess
04/19/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
04/19/2024
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
Christopher Burgess
10/24/2023
Permit issued — Structural
X00925357-S1-ST
10/24/2023
Permit issued — General Construction
X00925357-I1-GC
10/24/2023
Permit issued — Mechanical Systems
X00925357-S3-MS
10/19/2023
Objection resolved — Addressed
10/19/2023
Objection resolved — Addressed
10/19/2023
Objection resolved — Addressed
10/19/2023
Objection resolved — Addressed
10/19/2023
Objection resolved — Addressed
10/13/2023
Objection raised — Structural
10/13/2023
Objection raised — Fire_Protection
10/13/2023
Objection raised — Scope
10/13/2023
Objection raised — Fire_Protection
10/13/2023
Objection raised — Fire_Protection
10/10/2023
Objection resolved — Addressed
09/20/2023
Filed — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE HVAC REPLACEMENT AND REPLACEMENT OF ASSOCIATED DUCTWORK. NO CHANGE OF USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
X00925357-S3
09/18/2023
Objection resolved — Addressed
09/13/2023
Filed — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE HVAC REPLACEMENT AND REPLACEMENT OF ASSOCIATED DUCTWORK. NO CHANGE OF USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
X00925357-S2
09/13/2023
Objection raised — Zoning
09/13/2023
Objection raised — Fire_Protection
09/13/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Burgess
09/13/2023
Special inspection requirement — Maintenance information
Christopher Burgess
09/13/2023
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Burgess
09/13/2023
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Burgess
09/11/2023
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
Christopher Burgess
09/11/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
09/11/2023
Special inspection requirement — Post-installed Anchors
Christopher Burgess
09/07/2023
Filed — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE HVAC REPLACEMENT AND REPLACEMENT OF ASSOCIATED DUCTWORK. NO CHANGE OF USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
X00925357-S1
09/02/2023
Filed — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE HVAC REPLACEMENT AND REPLACEMENT OF ASSOCIATED DUCTWORK. NO CHANGE OF USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
X00925357-I1
08/25/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Burgess
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offROCK E SMALL PLBG&HTG INC08/22/2024
DOB NOWStructuralPermit IssuedCORINTHIAN DESIGNS10/24/2023
DOB NOWGeneral ConstructionPermit IssuedCORINTHIAN DESIGNS10/24/2023
DOB NOWMechanical SystemsPermit IssuedCORINTHIAN DESIGNS10/24/2023
BISOTISSUEDJ THOMAS CONSTRUCTION LLC07/17/2009
BISPLISSUEDVITELLO SEWER W.M H&P SER11/12/2003
BISPLISSUEDFINE TRIO PLUMBING INC07/10/2003
BISMHISSUEDOVR INC06/26/2003
BIS—ISSUEDSERVICE SIGN ERECTORS CO. INC06/22/1998
1 project · most recent 05/08/2024
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/08/2024Permit IssuedCORINTHIAN DESIGNS INCAir Conditioning Systems
Cooling
Mitsubishi Electric MODEL#: TPKFYP012LM140A 13,500 BTU · Vrf Indoor ×8
MODEL#: TPEFYP036OA140A 20,000 BTU · Vrf Indoor ×2
MODEL#: TPKFYP006LM140A 6,000 BTU · Vrf Indoor ×2
MODEL#: TPKFYP008LM140A 9,000 BTU · Vrf Indoor ×2
MODEL#: TPKFYP018LM140A 18,000 BTU · Vrf Indoor ×2
MODEL#: TUHYE1203AN40AN 135,000 BTU · Vrf Outdoor ×2
1 project · most recent 05/08/2024
Water/Sanitary
FiledStatusContractorScope
05/08/2024Signed-offROCK E SMALL PLBG&HTG INCWater/Sanitary
1 project · most recent 01/24/2024
General Wiring Lighting
FiledStatusContractorScope
01/24/2024CompleteY.S ELECTRICGeneral Wiring, Lighting
1 project · most recent 05/08/2024
Steel
FiledStatusContractorScope
05/08/2024Signed-offROCK E SMALL PLBG&HTG INCSteel
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
09/09/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/05/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 33
DateRequirementInspectorRole
05/09/2024Mechanical SystemsChristopher Burgessspecial
05/09/2024FinalChristopher Burgessprogress
05/09/2024HVAC-R and service water piping design and insulationChristopher Burgessenergy_progress
05/09/2024HVAC-R and service water heating equipmentChristopher Burgessenergy_progress
05/09/2024Shutoff dampersChristopher Burgessenergy_progress
05/09/2024HVAC-R and service water heating system controlsChristopher Burgessenergy_progress
05/09/2024Duct leakage testing, insulation and designChristopher Burgessenergy_progress
05/09/2024Post-installed AnchorsChristopher Burgessspecial
05/09/2024Fire-Resistant Penetrations and JointsChristopher Burgessspecial
05/09/2024Exhaust and Vent Systems in Plenums and DuctsChristopher Burgessspecial
05/09/2024Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)Christopher Burgessspecial
04/19/2024Duct leakage testing, insulation and designChristopher Burgessenergy_progress
04/19/2024HVAC-R and service water piping design and insulationChristopher Burgessenergy_progress
04/19/2024HVAC-R and service water heating equipmentChristopher Burgessenergy_progress
04/19/2024Shutoff dampersChristopher Burgessenergy_progress
04/19/2024Mechanical SystemsChristopher Burgessspecial
04/19/2024Post-installed AnchorsChristopher Burgessspecial
04/19/2024FinalChristopher Burgessprogress
04/19/2024HVAC-R and service water heating system controlsChristopher Burgessenergy_progress
04/19/2024Exhaust and Vent Systems in Plenums and DuctsChristopher Burgessspecial
04/19/2024Fire-Resistant Penetrations and JointsChristopher Burgessspecial
04/19/2024Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)Christopher Burgessspecial
09/13/2023HVAC-R and service water piping design and insulationChristopher Burgessenergy_progress
09/13/2023Maintenance informationChristopher Burgessenergy_progress
09/13/2023HVAC-R and service water heating system controlsChristopher Burgessenergy_progress
Latest 25 of 33.
▾Documents — 59 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/22/2026X00925357-S3Request digital key ↗
08/22/2026X00925357-P1Request digital key ↗
08/22/2026X00925357-S2Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION7
08/25/2024220119609Open ↗
08/25/2024220116871Open ↗
12/05/2011220094092Open ↗
Showing 3 of 7 on file for this type
▸BISPLACE OF ASSEMBLY1
05/31/2011220119609Open ↗
▸Seals & Professional Certifications22
▸DOB NOWProgress Inspector Seal & Signature7
09/17/2026X00925357-I1Open ↗
09/17/2026X00925357-I1Open ↗
08/28/2026X00925357-S3Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/17/2026X00925357-I1Open ↗
08/28/2026X00925357-S3Open ↗
08/28/2026X00925357-S3Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/22/2026X00925357-S3Open ↗
08/13/2026X00925357-I1Open ↗
08/13/2026X00925357-S1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
05/31/2011220119609Open ↗
05/05/2011220116871Open ↗
12/03/2010220094092Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
06/11/2011220116871Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST2
05/05/2011220116871Open ↗
12/03/2010220094092Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/22/2026X00925357-S3Open ↗
08/13/2026X00925357-S1Open ↗
08/13/2026X00925357-P1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS-EXEMPTION (ASB4)1
05/31/2011220119609Open ↗
▸Approvals, Objections & Sign-offs7
▸BISSCHEDULE A - OCCUPANCY / USE4
06/14/2011220116871Open ↗
05/05/2011220116871Open ↗
12/03/2010220094092Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
05/31/2011220119609Open ↗
05/05/2011220116871Open ↗
12/03/2010220094092Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
06/11/2011220116871Open ↗
05/05/2011220116871Open ↗
12/03/2010220094092Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET3
06/11/2011220116871Open ↗
05/05/2011220116871Open ↗
12/03/2010220094092Open ↗
▸Other Documents2
▸BISPLOT DIAGRAM2
05/05/2011220116871Open ↗
12/03/2010220094092Open ↗