← Back
BuildNYC
Two family frame
242 COVERT STREET
BROOKLYN · BIN 3079311
💬 Discuss this project
1920Year Built
2Stories
B2Building Class
R6Zoning
2,736 sfGross Floor Area
2Units
1 Active Violation ▸FDNY Report ↗
Two family frame · 1,900 sf lot · 1.44 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 28p · 2 filings · 20 docs
Floor 18p · 2 filings · 20 docs
Cellar7p · 2 filings · 20 docs
Sub-Basement7p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
USA Development1107/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/10/2022$1.9M—NEW STREET BK LLC → Private party$685/sf building
07/08/2021$855K—Private party → NEW STREET BK LLC$312/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LWL Associates411/22/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Prime Zone Building Consulting403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Stellar IndustriesGeneral Contractor107/08/2026
Top Dog Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Lam and Co Consulting8065211/22/2021
Building Lifecycle
03/08/2026
DOB summons issued for structure rendered non compliant due to smoke and sheetrock damage throughout from fire at 246 covert street, brooklyn
DOB violation · open
04/07/2022
Signed off — Alteration
EXISTING TWO STORY. CELLAR TO 2ND FLOOR BUILDING. PLUMBING WORK. AS PER PLANS. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION.
B00513863-I1
12/08/2021
Signed off — Alteration
INTERIOR RENOVATION WITH PARTITIONS. AS PER PLANS. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION.
B00513689-I1
12/07/2021
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/03/2021
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
27 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offStellar Industries07/06/2021
DOB NOWPlumbingSigned-offTop Dog Plumbing & Heating07/06/2021
1 project · most recent 08/18/2021
General Wiring
FiledStatusContractorScope
08/18/2021CompleteRoyal Electrical ContractingGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
12/07/2021Pass-Final General Construction Non-Directive 14PassView ↗
12/03/2021Fail-Final General Construction Non-Directive 14FailView ↗
10/11/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/10/2021Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/02/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/26/2021No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
11/26/2021Fire-Resistant Penetrations and JointsCHI WAI CHUNGspecial
11/26/2021Energy Code Compliance InspectionsCHI WAI CHUNGprogress
11/26/2021Fenestration areasCHI WAI CHUNGenergy_progress
11/26/2021Fenestration air leakageCHI WAI CHUNGenergy_progress
11/26/2021Air barrier - visual inspectionCHI WAI CHUNGenergy_progress
11/26/2021Fenestration and door U-factor and product ratingsCHI WAI CHUNGenergy_progress
11/26/2021Air barrier — testing CHI WAI CHUNGenergy_progress
11/26/2021Interior lighting powerCHI WAI CHUNGenergy_progress
11/26/2021Energy Code Compliance InspectionsCHI WAI CHUNGprogress
11/26/2021HVAC-R and service water heating equipmentCHI WAI CHUNGenergy_progress
11/26/2021HVAC-R and service water heating system controlsCHI WAI CHUNGenergy_progress
11/26/2021HVAC-R and service water piping design and insulationCHI WAI CHUNGenergy_progress