← Back
Walk-up apt, over six families with stores
242 EAST 40 STREET
MANHATTAN · Murray Hill-Kips Bay · BIN 1020384
💬 Discuss this project
1920Year Built
4Stories
C7Building Class
C1-9Zoning
4,500 sfGross Floor Area
8Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Walk-up apt, over six families with stores · Owner of record: GRAND CENTRAL 888 INC. · 1,778 sf lot · 2.53 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Roof1p · 1 filing · 12 docs
Floor 11 filing · 12 docs
Mezzanine1p · 1 filing · 7 docs
Basement3p · 1 filing · 12 docs
Sub-Basement4p · 2 filings · 19 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
THOMACY1407/08/2026
HKS CONSTRUCTION503/21/2026
GRAND CENTRAL 888 INC403/22/2026
SKYWORX CONTRACTING INC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DESIGN GROUP IN H&K LLC302/03/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DESIGN GROUP IN H K603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SIN DO CONSTRUCTION INCGeneral Contractor603/21/2026
H POWER LLCGeneral Contractor303/21/2026
TORRES IVANElectrical203/21/2026
FLUSHING PLUMBING CORPPlumbing207/08/2026
HEMNAUTH, SUDESHElectrical103/21/2026
WALTON, MARCElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DESIGN GROUP IN H&K LLC1363302/03/2023
Building Lifecycle
All (24)Filed (3)Permit Issued (5)Signed Off (1)Violation (11)Inspection (4)
04/29/2026
Violation issued (HPD, closed)
A
09/25/2023
Signed off — Alteration
INSTALLATION/MODIFICATION OF PLUMBING SYSTEM AT EXISTING RESTAURANT (KITCHEN AREA) IN CONJUNCTION WITH DOB#M00688128. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
M00688140-I1
03/24/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/09/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/09/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/06/2023
Permit issued — Plumbing
M00688140-I1-PL
02/27/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/03/2023
Filed — Alteration
INSTALLATION/MODIFICATION OF PLUMBING SYSTEM AT EXISTING RESTAURANT (KITCHEN AREA) IN CONJUNCTION WITH DOB#M00688128. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
M00688140-P1
12/06/2022
Violation issued (ECB, closed)
Unknown
10/26/2022
Permit issued — Mechanical Systems
M00688128-I1-GC-CX
06/23/2022
Permit issued — Plumbing
M00688140-I1-PL
05/18/2022
Permit issued — General Construction
M00688128-I1-GC-CX
03/23/2022
Permit issued — General Construction
M00688128-I1-GC-CX
03/22/2022
Filed — Alteration
INSTALLATION/MODIFICATION OF PLUMBING SYSTEM AT EXISTING RESTAURANT (KITCHEN AREA) IN CONJUNCTION WITH DOB#M00688128. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
M00688140-I1
03/15/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING RESTAURANT AT BASEMENT LEVEL. WORK INCLUDES REMOVAL/INSTALLATION OF NON-BEARING PARTITIONS, GENERAL CARPENTRY WORK, AND REPLACEMENT OF MECHANICAL SYSTEM AS PER PLANS HEREWITH. NO CHANGE IN USE, EGRESS, AND OCCUPANCY.
M00688128-I1
04/01/2021
Violation issued (HPD, closed)
A
10/05/2018
Violation issued (HPD, closed)
I
07/01/2017
Violation issued (ECB, closed)
Construction
11/09/2015
Violation issued (FDNY_NOV, closed)
08/06/2008
Violation issued (FDNY_NOV, closed)
12/14/2007
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/14/2007
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/13/2006
Violation issued (FDNY_NOV, closed)
09/06/2005
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offFLUSHING PLUMBING CORP03/06/2023
DOB NOWMechanical SystemsPermit IssuedH POWER LLC10/26/2022
DOB NOWPlumbingSigned-offFLUSHING PLUMBING CORP06/23/2022
DOB NOWGeneral ConstructionPermit IssuedSIN DO CONSTRUCTION INC05/18/2022
DOB NOWGeneral ConstructionPermit IssuedSIN DO CONSTRUCTION INC03/23/2022
BISEQISSUEDHKS CONSTRUCTION CORP01/26/2018
BISOTISSUEDSUPER US CONTRACTING INC11/01/2017
BISEQISSUEDHKS CONSTRUCTION CORP01/27/2017
BISBLISSUEDBAYSIDE FUEL12/17/2004
BISFBISSUEDPUBLIC FUEL SERVICE CO.12/30/1993
BISFPISSUEDMASTER FIRE PREVENTION SYS INC11/15/1993
BISOTISSUEDTING DAK CONTRACTOR INC.08/26/1993
BISFPISSUEDMASTER FIRE INC03/12/1992
1 project · most recent 03/15/2022
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/15/2022Permit IssuedH POWER LLCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Fujitsu AOU24R1A 23,000 BTU · Condensing Unit ×1
AOU60RLAVM 60 BTU · Condensing Unit ×1
AOU72RLAVL 72,000 BTU · Condensing Unit ×1
Heating
Fujitsu ASU24RLF 25,200 BTU · Split System ×5
ASU36RLXB 34,000 BTU · Split System ×1
Ventilation
__Junk__ TBD 3,000 CFM · Kitchen Exhaust ×1
1 project · most recent 01/07/2023
General Wiring
FiledStatusContractorScope
01/07/2023Permit IssuedMAC ELECT'L CONTR. INC.General Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
03/24/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/09/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/09/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/27/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
02/01/2023Fire-Resistant Penetrations and JointsSUKHWAN KIMspecial
02/25/2022Mechanical SystemsSUKHWAN KIMspecial
02/25/2022Interior lighting powerSUKHWAN KIMenergy_progress
02/25/2022HVAC-R and service water heating system controlsSUKHWAN KIMenergy_progress
02/25/2022Energy Code Compliance InspectionsSUKHWAN KIMprogress
02/25/2022Fire-Resistant Penetrations and JointsSUKHWAN KIMspecial
02/25/2022Lighting controlsSUKHWAN KIMenergy_progress
02/25/2022HVAC-R and service water heating equipmentSUKHWAN KIMenergy_progress
02/25/2022HVAC-R and service water piping design and insulationSUKHWAN KIMenergy_progress
02/25/2022FinalSUKHWAN KIMprogress
▾Documents — 64 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
09/02/2026M00688128-I1Request digital key ↗
08/31/2026M00688140-P1Request digital key ↗
08/31/2026M00688140-I1Request digital key ↗
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION6
10/02/2018140691231Open ↗
12/11/2017140691231Open ↗
11/01/2017140691231Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION3
01/29/2018140598422Open ↗
11/01/2017140691231Open ↗
01/25/2017140598422Open ↗
▸Seals & Professional Certifications21
▸DOB NOWProgress Inspector Seal & Signature7
09/01/2026M00688128-I1Open ↗
09/01/2026M00688128-I1Open ↗
09/01/2026M00688128-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
09/02/2026M00688128-I1Open ↗
08/31/2026M00688140-I1Open ↗
08/13/2026M00688140-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026M00688128-I1Open ↗
09/01/2026M00688128-I1Open ↗
09/01/2026M00688140-P1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
09/07/2017140691231Open ↗
01/25/2017140598422Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
09/07/2017140691231Open ↗
01/25/2017140598422Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
09/07/2017140691231Open ↗
01/25/2017140598422Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
11/26/2018140691231Open ↗
09/11/2018140598422Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
11/01/2017140691231Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/02/2026M00688128-I1Open ↗
08/31/2026M00688140-I1Open ↗
08/13/2026M00688140-P1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/07/2017140691231Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
11/01/2017140691231Open ↗
09/07/2017140691231Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
11/26/2018140691231Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
09/07/2017140691231Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
11/26/2018140691231Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
11/01/2017140691231Open ↗
09/07/2017140691231Open ↗
01/25/2017140598422Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
11/26/2018140691231Open ↗
09/11/2018140598422Open ↗
▸BISSHED LETTER1
01/29/2018140598422Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
11/26/2018140691231Open ↗
09/07/2017140691231Open ↗
▸Filing & Intake Forms12
▸BISADDITIONAL INFORMATION6
10/04/2018140691231Open ↗
10/02/2018140691231Open ↗
11/01/2017140691231Open ↗
Showing 3 of 6 on file for this type
▸BISBOROUGH INTAKE FORM4
11/26/2018140691231Open ↗
09/11/2018140598422Open ↗
12/05/2017140691231Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
09/07/2017140691231Open ↗
01/25/2017140598422Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
11/26/2018140691231Open ↗