← Back
Over six families without stores
246 EAST 119 STREET
MANHATTAN · East Harlem (North) · BIN 1054553
💬 Discuss this project
1900Year Built
5Stories
C1Building Class
R9AZoning
9,750 sfGross Floor Area
10Units
Rent Stabilized63 Open Violations ▸
Over six families without stores · 3,168 sf lot · 3.08 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 1 filing · 4 docs
Floor 5Under Construction1p · 1 filing · 4 docs
Floor 4Under Construction1p · 1 filing · 4 docs
Floor 3Under Construction1p · 1 filing · 4 docs
Floor 2Under Construction1p · 1 filing · 4 docs
Floor 1Under Construction6p · 2 filings · 5 docs
Site & exteriorUnder Construction7p · 1 filing · 2 docs
Filed — no permit issued40p · 1 filing · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
JASCO909/13/2026
LA CASA NUESTRA HDFC203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RODNEY D. GIBBLE CONSULTING ENGINEE206/22/2026
MCHENERY TESTING LAB105/13/2026
L. NAOUM, P.E., P. C.203/27/2026
ESKW/A103/25/2026
MJE PROFESSIONAL SERVICES108/04/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SNR EXPEDITING DESIGN203/21/2026
MUNICIPAL BUILDING CONSULTANTS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JASCO, INCGeneral Contractor407/08/2026
AKALA CONSTRUCTIONGeneral Contractor207/31/2026
DELUXE CONSTRUCTION ANDGeneral Contractor106/27/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519112/17/2025
Building Lifecycle
All (107)Filed (7)Permit Issued (5)Violation (60)Objection (5)Special Inspection (30)
07/30/2026
Permit issued — Sidewalk Shed
M01265731-I1-SH
07/30/2026
Permit issued — Supported Scaffold
M01401870-I1-SF
07/21/2026
Violation issued (HPD, open)
B
07/21/2026
Violation issued (HPD, open)
B
07/21/2026
Violation issued (HPD, open)
B
07/21/2026
Violation issued (HPD, open)
A
07/21/2026
Violation issued (HPD, open)
A
07/21/2026
Violation issued (HPD, open)
A
07/15/2026
Objection raised — Scope
06/23/2026
Permit issued — Structural
M01278698-I1-ST
06/22/2026
Filed — Alteration
HEREWITH FILING MECHANICAL WORK AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01355679-S3
06/01/2026
Special inspection requirement — Final
06/01/2026
Special inspection requirement — Structural Steel - High Strength Bolting
06/01/2026
Special inspection requirement — Structural Steel - Details
06/01/2026
Special inspection requirement — Structural Steel - Welding
06/01/2026
Special inspection requirement — Tenant Protection Plan Compliance
06/01/2026
Special inspection requirement — Masonry
06/01/2026
Special inspection requirement — Post-installed Anchors
06/01/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
05/14/2026
Permit issued — Supported Scaffold
M01401870-I1-SF
05/13/2026
Filed — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M01401870-I1
04/29/2026
Violation issued (HPD, closed)
A
04/16/2026
Objection raised — Plumbing
04/12/2026
Objection raised — Scope
04/12/2026
Objection raised — Cost
04/12/2026
Objection raised — Admin
04/06/2026
Violation issued (HPD, open)
B
04/06/2026
Violation issued (HPD, open)
B
04/06/2026
Violation issued (HPD, closed)
A
04/06/2026
Violation issued (HPD, open)
B
04/06/2026
Violation issued (HPD, open)
B
03/27/2026
Filed — Alteration
HEREWITH FILING MECHANICAL WORK AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01355679-S2
03/27/2026
Filed — Alteration
HEREWITH FILING MECHANICAL WORK AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01355679-S1
03/25/2026
Filed — Alteration
HEREWITH FILING MECHANICAL WORK AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01355679-I1
03/25/2026
Special inspection requirement — Tenant Protection Plan Compliance
03/25/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/25/2026
Special inspection requirement — Masonry
03/25/2026
Special inspection requirement — Tenant Protection Plan Compliance
03/25/2026
Special inspection requirement — Energy Code Compliance Inspections
03/25/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/25/2026
Special inspection requirement — Fenestration air leakage
03/25/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
03/25/2026
Special inspection requirement — Interior lighting power
03/25/2026
Special inspection requirement — Insulation placement and R values
03/25/2026
Special inspection requirement — Lighting controls
03/25/2026
Special inspection requirement — Air barrier - visual inspection
03/25/2026
Special inspection requirement — Exterior lighting power
03/25/2026
Special inspection requirement — Fire-Resistance Rated Construction
03/25/2026
Special inspection requirement — Heating Systems
03/25/2026
Special inspection requirement — Tenant Protection Plan Compliance
03/25/2026
Special inspection requirement — Energy Code Compliance Inspections
03/25/2026
Special inspection requirement — HVAC-R and service water heating system controls
03/25/2026
Special inspection requirement — HVAC-R and service water heating equipment
03/25/2026
Special inspection requirement — Maintenance information
03/25/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
02/04/2026
Special inspection requirement — Final
02/01/2026
Violation issued (HPD, open)
C
02/01/2026
Violation issued (HPD, open)
C
12/17/2025
Filed — Alteration
M01278698-I1
12/10/2025
Violation issued (ECB, open)
Construction
Latest 60 of 107 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedAKALA CONSTRUCTION INC07/30/2026
DOB NOWSupported ScaffoldPermit IssuedAKALA CONSTRUCTION INC07/30/2026
DOB NOWStructuralPermit IssuedDELUXE CONSTRUCTION AND06/23/2026
DOB NOWSupported ScaffoldPermit IssuedJASCO, INC05/14/2026
DOB NOWSidewalk ShedPermit IssuedJASCO, INC08/04/2025
BISEQISSUEDCOLGATE SCAFFOLDING & EQUIPMENT04/28/2004
BISSPISSUEDTMS PLUMBING & HTG CORP11/21/2002
BISPLISSUEDTMS PLMBG & HTG CORP11/21/2002
BISPLISSUEDTMS PLMBG & HTG CORP11/21/2002
BISOTISSUEDEASTERN GENERAL CONSTRUCT10/30/2001
BISOTISSUEDMART CONST. CO, INC12/13/2000
BISEQISSUEDTAJ CONST. CO.10/17/2000
BISEQISSUEDG & N ALUMINUM SIDING INC06/08/1998
BISPLISSUEDJOHN RAGOUSSIS SONS INC04/14/1997
BISBLISSUEDJOHN RAGOUSSIS SONS INC04/14/1997
BISOTISSUEDSZ CONSTRUCTION11/21/1994
1 project · most recent 06/22/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/22/2026——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Ephoca ×35
Mitsubishi Electric MSZ-GX12NL 12,000 BTU · Fan Coil Indoor ×2
MXZ-4D30NL 28,400 BTU · Heat Pump Outdoor ×1
Ventilation
Greenheck G-097-VG 100 CFM · Exhaust Fan ×3
1 project · most recent 06/22/2026
Water/Sanitary
FiledStatusContractorScope
06/22/2026——Water/Sanitary
1 project · most recent 07/30/2026
FiledStatusContractorScope
07/30/2026Permit IssuedRICHARD NEU—
1 project · most recent 06/22/2026
Steel Masonry
FiledStatusContractorScope
06/22/2026——Steel, Masonry
2 projects · most recent 05/13/2026
Scaffold Sidewalk Shed
FiledStatusContractorScope
05/13/2026Permit IssuedAKALA CONSTRUCTION INCScaffold
08/04/2025Permit IssuedAKALA CONSTRUCTION INCSidewalk Shed
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
06/01/2026Final—progress
06/01/2026Structural Steel - High Strength Bolting—special
06/01/2026Structural Steel - Details—special
06/01/2026Structural Steel - Welding—special
06/01/2026Tenant Protection Plan Compliance—special
06/01/2026Masonry—special
06/01/2026Post-installed Anchors—special
06/01/2026Structural Stability – Alterations of existing buildings—special
03/25/2026Tenant Protection Plan Compliance—special
03/25/2026Fire-Resistant Penetrations and Joints—special
03/25/2026Masonry—special
03/25/2026Tenant Protection Plan Compliance—special
03/25/2026Energy Code Compliance Inspections—progress
03/25/2026Fire-Resistant Penetrations and Joints—special
03/25/2026Fenestration air leakage—energy_progress
03/25/2026Fenestration and door U-factor and product ratings—energy_progress
03/25/2026Interior lighting power—energy_progress
03/25/2026Insulation placement and R values—energy_progress
03/25/2026Lighting controls—energy_progress
03/25/2026Air barrier - visual inspection—energy_progress
03/25/2026Exterior lighting power—energy_progress
03/25/2026Fire-Resistance Rated Construction—progress
03/25/2026Heating Systems—special
03/25/2026Tenant Protection Plan Compliance—special
03/25/2026Energy Code Compliance Inspections—progress
Latest 25 of 32.
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/20/2026M01278698-I1Request digital key ↗
08/18/2026M01355679-S3Request digital key ↗
08/18/2026M01355679-S2Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/20/2026M01278698-I1Open ↗
08/18/2026M01355679-S3Open ↗
08/18/2026M01355679-S2Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/20/2026M01278698-I1Open ↗
▸Approvals, Objections & Sign-offs5
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter5
08/20/2026M01278698-I1Open ↗
08/18/2026M01355679-S3Open ↗
08/13/2026M01355679-S2Open ↗
Showing 3 of 5 on file for this type
▸Other Documents1
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/14/2026M01355679-I1Open ↗