← Back
Cape Cod
248-34 54 AVENUE
QUEENS · BIN 4170845
💬 Discuss this project
1950Year Built
1.5Stories
A0Building Class
R2AZoning
1,225 sfGross Floor Area
1Units
Cape Cod · 5,000 sf lot · 0.25 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 13 docs
Floor 21p · 1 filing · 13 docs
Floor 1
1 job · most recent 05/30/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/30/2025——Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-8C60NA MXZ-4C36NA 90,000 BTU · Split System ×2
1 job · most recent 05/30/2025
Water/Sanitary
FiledStatusContractorScope
05/30/2025——Water/Sanitary
Building Lifecycle
All (40)Filed (2)Objection (20)Special Inspection (18)
05/11/2026
Objection resolved — Resolved
04/01/2026
Special inspection requirement — Interior lighting power
04/01/2026
Special inspection requirement — Ventilation and air distribution system
03/11/2026
Special inspection requirement — Maintenance information
03/10/2026
Special inspection requirement — HVAC-R and service water heating equipment
03/10/2026
Special inspection requirement — HVAC-R and service water heating system controls
03/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
12/18/2025
Objection resolved — Addressed
12/18/2025
Objection resolved — Addressed
12/18/2025
Objection resolved — Addressed
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection resolved — Addressed
09/29/2025
Objection raised — Cost
09/05/2025
Objection resolved — Addressed
07/30/2025
Objection raised — Structural
06/17/2025
Objection raised — Scope
06/17/2025
Objection resolved — Addressed
05/30/2025
Filed — Alteration CO
ALTERATIONS TO EXIST. ATTIC FLOOR. NEW CERTIFICATE OF OCCUPANCY REQUIRED. ALTERATIONS TO INCLUDE NEW NON-LOAD BEARING PARTITIONS AND FINISHES.
Q01169995-S1
04/24/2025
Objection resolved — Addressed
03/21/2025
Objection raised — Scope
03/20/2025
Objection raised — Fire_Protection
03/20/2025
Objection raised — Structural
03/20/2025
Objection raised — Admin
03/20/2025
Objection raised — Inspections
03/20/2025
Objection raised — Scope
03/20/2025
Objection raised — Admin
03/20/2025
Objection raised — Scope
03/11/2025
Filed — Alteration CO
ALTERATIONS TO EXIST. ATTIC FLOOR. NEW CERTIFICATE OF OCCUPANCY REQUIRED. ALTERATIONS TO INCLUDE NEW NON-LOAD BEARING PARTITIONS AND FINISHES.
Q01169995-I1
02/14/2025
Special inspection requirement — Air barrier - visual inspection
02/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/14/2025
Special inspection requirement — Fenestration air leakage
02/14/2025
Special inspection requirement — Fenestration areas
02/14/2025
Special inspection requirement — Insulation placement and R values
02/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/14/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
02/14/2025
Special inspection requirement — Energy Code Compliance Inspections
02/14/2025
Special inspection requirement — Fire-Resistance Rated Construction
02/14/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
01/21/2025
Special inspection requirement — Final
01/21/2025
Special inspection requirement — Mechanical Systems
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
44-07 69TH STREET REALTY203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BOLT ARCHITECTURE, PLLC205/30/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ALFREDO T FREDERICKS RA403/21/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISPLISSUEDPRIMO P & H INC08/31/2005
BIS—ISSUEDITM CONSTRUCTION CORP07/20/2005
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
04/01/2026Interior lighting power—energy_progress
04/01/2026Ventilation and air distribution system—energy_progress
03/11/2026Maintenance information—energy_progress
03/10/2026HVAC-R and service water heating equipment—energy_progress
03/10/2026HVAC-R and service water heating system controls—energy_progress
03/10/2026HVAC-R and service water piping design and insulation—energy_progress
02/14/2025Air barrier - visual inspection—energy_progress
02/14/2025Fire-Resistant Penetrations and Joints—special
02/14/2025Fenestration air leakage—energy_progress
02/14/2025Fenestration areas—energy_progress
02/14/2025Insulation placement and R values—energy_progress
02/14/2025Fire-Resistant Penetrations and Joints—special
02/14/2025Structural Stability – Alterations of existing buildings—special
02/14/2025Energy Code Compliance Inspections—progress
02/14/2025Fire-Resistance Rated Construction—progress
02/14/2025Fenestration and door U-factor and product ratings—energy_progress
01/21/2025Final—progress
01/21/2025Mechanical Systems—special
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/14/2026Q01169995-S1Request digital key ↗
08/14/2026Q01169995-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/14/2026Q01169995-I1Open ↗
08/13/2026Q01169995-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01169995-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026Q01169995-S1Open ↗
08/20/2026Q01169995-I1Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026Q01169995-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/14/2026Q01169995-I1Open ↗
▸Other Documents4
▸DOB NOWPlot Diagram1
08/13/2026Q01169995-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/14/2026Q01169995-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01169995-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01169995-I1Open ↗