← Back
BuildNYC
Three families
248 HOYT STREET
BROOKLYN · BIN 3006724
💬 Discuss this project
1899Year Built
3Stories
C0Building Class
R6BZoning
2,700 sfGross Floor Area
3Units
Rent Stabilized5 Active Violations ▸FDNY Report ↗
Three families · 1,560 sf lot · 1.73 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalLandscape
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofConversion of 3-family dwelling into 2-family31p · 2 filings · 20 docs
Floor 3Conversion of 3-family dwelling into 2-family38p · 3 filings · 20 docs
Floor 2Conversion of 3-family dwelling into 2-family36p · 3 filings · 20 docs
Floor 1Conversion of 3-family dwelling into 2-family37p · 3 filings · 20 docs
CellarConversion of 3-family dwelling into 2-family40p · 3 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/16/2023$2.4M—Private party → Private party$870/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Kris Kozlowski Architect210/23/2025
Pebble Studio Design810/29/2024
Tom Petersen Architect107/10/2024
MW Professional Engineering202/09/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Robert S Schnitzer203/21/2026
Self Employed103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Home Work Additions & RenGeneral Contractor407/08/2026
Centurion Solar EnergyGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Kris Kozlowski Architect3955110/23/2025
Welldone Inspection8628410/23/2025
Thomas Petersen Architect7854107/10/2024
MW Professional Engineering570202/09/2024
Building Lifecycle
08/03/2026
Objection resolved — Resolved
07/01/2026
Objection resolved — Addressed
05/05/2026
(a) § hmc:file annual bedbug report in accordance with HPD rule as described on the back of this notice of violation or as described on HPDs…
HPD violation · open
04/28/2026
Objection resolved — Addressed
02/12/2026
Signed off — Alteration CO
RECONFIGURE THE UNIT LAYOUT OF THE EXISTING 3-STORY WITH CELLAR, ATTACHED (3)-FAMILY RESIDENCE. INTERIOR RENOVATION INCLUDES REMOVAL AND INSTALLATION OF PARTITIONS, KITCHEN & BATHROOM CHANGES, INTERIOR FINISHES. NO CHANGE IN USE OR OCCUPANCY.
B00896341-S2
102 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedHome Work Additions & Ren05/16/2025
DOB NOWSolarSigned-offCenturion Solar Energy08/19/2024
DOB NOWGeneral ConstructionPermit IssuedHome Work Additions & Ren02/20/2024
DOB NOWStructuralSigned-offHome Work Additions & Ren02/16/2024
DOB NOWGeneral ConstructionSigned-offHome Work Additions & Ren01/02/2024
BISEQISSUEDSSP Construction04/27/2017
1 project · most recent 10/23/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScope
10/23/2025Permit IssuedHome Work Additions & RenHeating and Air Conditioning Systems, Ventilation Systems
1 project · most recent 08/14/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/14/2024——Gas, Storm, Water/Sanitary
2 projects · most recent 05/27/2025
General Wiring
FiledStatusContractorScope
05/27/2025Permit IssuedJRS ElectricGeneral Wiring
07/10/2024CompleteBerger Quality Electrical Con—
1 project · most recent 10/23/2025
Steel Concrete Wood
FiledStatusContractorScope
10/23/2025Permit IssuedHome Work Additions & RenSteel, Concrete, Wood
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
07/01/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/20/2024Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 47
DateRequirementInspectorRole
10/20/2025Fenestration air leakageKris Kozlowskienergy_progress
10/20/2025Permanent certificateKris Kozlowskienergy_progress
10/20/2025Air barrier - visual inspectionKris Kozlowskienergy_progress
10/20/2025Maintenance informationKris Kozlowskienergy_progress
10/20/2025Fenestration and door U-factor and product ratingsKris Kozlowskienergy_progress
10/20/2025Fenestration areasKris Kozlowskienergy_progress
10/20/2025Interior lighting powerKris Kozlowskienergy_progress
10/20/2025MeteringKris Kozlowskienergy_progress
10/20/2025Fire-Resistant Penetrations and JointsKris Kozlowskispecial
10/20/2025Structural Stability – Alterations of existing buildingsQIUFAN JIANGspecial
10/20/2025Energy Code Compliance InspectionsKris Kozlowskiprogress
10/20/2025Fire-Resistance Rated ConstructionKris Kozlowskiprogress
12/11/2024Structural Stability – Alterations of existing buildings—special
12/11/2024Permanent certificateQIUFAN JIANGenergy_progress
12/11/2024Structural Stability – Alterations of existing buildingsQIUFAN JIANGspecial
12/11/2024Energy Code Compliance InspectionsQIUFAN JIANGprogress
12/11/2024Fire-Resistance Rated ConstructionQIUFAN JIANGprogress
12/11/2024Maintenance informationQIUFAN JIANGenergy_progress
12/11/2024Fenestration areasQIUFAN JIANGenergy_progress
12/11/2024Interior lighting powerQIUFAN JIANGenergy_progress
12/11/2024MeteringQIUFAN JIANGenergy_progress
12/11/2024Fenestration air leakageQIUFAN JIANGenergy_progress
12/11/2024Fenestration and door U-factor and product ratingsQIUFAN JIANGenergy_progress
12/11/2024Fire-Resistant Penetrations and JointsQIUFAN JIANGspecial
12/11/2024Air barrier - visual inspectionQIUFAN JIANGenergy_progress
Latest 25 of 47.
100 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account