← Back
Primarily 2 family with 1 store or office
249 BUSHWICK AVENUE
BROOKLYN · BIN 3071253
💬 Discuss this project
1930Year Built
3Stories
S2Building Class
R6Zoning
3,600 sfGross Floor Area
3Units
2 Open Violations 1 unresolved · 1 paperwork only ▸FDNY Report ↗
Primarily 2 family with 1 store or office · 1,375 sf lot · 2.62 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 15p · 1 filing · 14 docs
Cellar8p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PAK PING NG 1103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SU ARCHITECT, P.C.201/14/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WHITESTONE PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SU ARCHITECT PC6857201/14/2021
Building Lifecycle
All (23)Filed (2)Permit Issued (1)Violation (11)Inspection (3)Special Inspection (6)
11/09/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/09/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/09/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/07/2021
Permit issued — Plumbing
B00443261-I1-PL
05/22/2021
Violation issued (ECB, closed)
Construction
04/13/2021
Violation issued (ECB, closed)
Construction
01/21/2021
Violation issued (ECB, open)
Construction
01/21/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
QIANG SU
01/21/2021
Special inspection requirement — Energy Code Compliance Inspections
QIANG SU
01/21/2021
Special inspection requirement — HVAC insulation and sealing
QIANG SU
01/14/2021
Filed — Alteration
B00443261-P1
01/14/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
QIANG SU
01/14/2021
Special inspection requirement — Energy Code Compliance Inspections
QIANG SU
01/14/2021
Special inspection requirement — HVAC insulation and sealing
QIANG SU
12/24/2020
Filed — Alteration
B00443261-I1
09/23/2020
Violation issued (ECB, open)
Construction
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/21/2020
Violation issued (ECB, closed)
Construction
12/22/2014
Violation issued (FDNY_NOV, closed)
10/21/2014
Violation issued (ECB, closed)
Construction
06/17/1992
Violation issued (ECB, closed)
Construction
06/17/1992
Violation issued (ECB, closed)
Construction
06/17/1992
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedWHITESTONE PLUMBING CORP07/07/2021
BISOTISSUEDSPLEN CONSTRUCTION INC07/07/2021
BISPLISSUEDASIAAM INC07/08/1998
BISOTISSUEDGOMMES CONTRACTING CO12/23/1994
1 project · most recent 05/31/2021
General Wiring
FiledStatusContractorScope
05/31/2021Permit IssuedR & T ELECTRICAL CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
11/09/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/09/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/09/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
01/21/2021Fire-Resistant Penetrations and JointsQIANG SUspecial
01/21/2021Energy Code Compliance InspectionsQIANG SUprogress
01/21/2021HVAC insulation and sealing QIANG SUenergy_progress
01/14/2021Fire-Resistant Penetrations and JointsQIANG SUspecial
01/14/2021Energy Code Compliance InspectionsQIANG SUprogress
01/14/2021HVAC insulation and sealing QIANG SUenergy_progress
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Plumbing2
09/01/2026B00443261-I1Request digital key ↗
08/15/2026B00443261-P1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
01/28/2021340740005Open ↗
09/21/2020340740005Open ↗
▸BISWORK PERMIT APPLICATION1
07/07/2021340740005Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
04/12/2023340740005Open ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature4
09/23/2026B00443261-I1Open ↗
09/23/2026B00443261-I1Open ↗
09/01/2026B00443261-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
09/01/2026B00443261-I1Open ↗
09/01/2026B00443261-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026B00443261-I1Open ↗
09/01/2026B00443261-P1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
01/28/2021340740005Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
01/28/2021340740005Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
03/10/2021340740005Open ↗
▸Safety & Tenant Protection4
▸BISTenant Protection Plan and Notes2
03/10/2021340740005Open ↗
01/28/2021340740005Open ↗
▸DOB NOWTenant Protection Plan2
08/13/2026B00443261-P1Open ↗
08/13/2026B00443261-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
09/01/2026B00443261-P1Open ↗
09/01/2026B00443261-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/07/2020340740005Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
01/28/2021340740005Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
03/10/2021340740005Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
01/28/2021340740005Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
01/28/2021340740005Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
03/10/2021340740005Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
03/10/2021340740005Open ↗
01/28/2021340740005Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
01/28/2021340740005Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
01/28/2021340740005Open ↗