← Back
BuildNYC
MANHATTAN
249 EAST 62ND STREET
MANHATTAN · BIN 1090660
💬 Discuss this project
—Year Built
—Stories
—Building Class
C5-1Zoning
—Gross Floor Area
—Units
0 Active Violations
8,026 sf lot · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentLandscapeCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Whole building & multi-floor projects249 E 62nd St LLC3 filings
RoofZeckendorf Development, LLC5p · 2 filings · 6 docs
Floor 19Zeckendorf Development, LLC1p · 1 filing · 2 docs
Floor 18
Floor 17
Floor 16
Floor 15
Floor 14
Floor 13
Floor 12
Floor 11
Floor 10
Floor 9
Floor 8
Floor 7
Floor 6
Floor 5
Floor 4
Floor 3
Floor 2Temporary pipe scaffold installation2p · 2 filings · 8 docs
Floor 1Randy's Donuts, Clue PilatesUnder Construction6p · 5 filings · 14 docs
Cellar1 filing · 2 docs
Site & exteriorCp Of Ues, INC.13 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Zeckendorf Realty13307/08/2026
Moluka Enterprises1603/21/2026
249 E 62nd St603/21/2026
CP of Ues503/22/2026
Dart Interests410/04/2026
Blair House Associates103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/04/2015$64.3M—MOLUKA ENTERPRISES, L.L.C. → 249 E 62ND ST LLC— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Prospect Associates109/24/2026
Nicholaos Moshopoulos206/12/2026
Richard Wainer Architect103/02/2025
Dewberry Engineers310/17/2024
NS Engineers106/27/2024
Icor Associates511/10/2023
KZ Engineering1508/29/2023
Enthink Engineers612/22/2022
Lombardo Professional Engineering206/09/2022
Tohfaz Uddin PE504/04/2022
Gga Studios207/23/2021
Asif Jamil, RA110/31/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Synergy Building Consultants2003/21/2026
Louis Striar203/21/2026
NY Expediters103/21/2026
JM Zoning1403/21/2026
Domani Consulting203/21/2026
Green Studio203/21/2026
Lombardo Building Consultants203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Colgate EnterpriseScaffold2607/08/2026
KG SprinklerFire Protection907/08/2026
CM and Associates ConstructionScaffold707/08/2026
Andamio ScaffoldingScaffold707/08/2026
Platinum Services NYScaffold303/21/2026
MonconScaffold303/21/2026
Donato Plumbing GroupPlumbing307/08/2026
Rock Group NYScaffold207/08/2026
CM and Associates ConstructionGeneral Contractor204/09/2026
Headquarters MechanicalPlumbing207/08/2026
Z-Car-DSign hanger107/08/2026
American Standard P&H CororpPlumbing106/28/2026
Apn BuildersGeneral Contractor106/27/2026
DoriaScaffold107/08/2026
A & M Electrical ServiceElectrical103/22/2026
Unitech DesignSign hanger109/26/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Nko Architect6811206/12/2026
Delta Testing Labs687706/27/2024
Enthink Engineers6247412/22/2022
Leo Y Lee Associates2481106/09/2022
Tohfaz Uddin P.E2001404/04/2022
Building Lifecycle
All (237)Filed (46)Permit Issued (52)Signed Off (23)Violation (60)Inspection (17)Objection (24)Special Inspection (15)
10/07/2026
Signed off — Alteration
WINDOW INSPECTION AND MAINTENANCE VIA INDUSTRIAL ROPE ACCESS
M01448517-I1
09/25/2026
Permit issued — Sign
M01459055-I1-SG
09/24/2026
Filed — Alteration
PROPOSED INSTALLATION OF 1 ILLUMINATED NON-FLASHING ACCESSORY BUSINESS SIGN. WORDING "World Famous Since 1952" "RANDY'S DONUTS"
M01459055-I1
09/11/2026
Special inspection requirement — Final
JUSTIN KIM
09/09/2026
Permit issued — Suspended Scaffold
M01448517-I1-SC
08/19/2026
Filed — Alteration
WINDOW INSPECTION AND MAINTENANCE VIA INDUSTRIAL ROPE ACCESS
M01448517-I1
08/14/2026
Signed off — Alteration
herewith filing temporary construction fence on DOT approved jersey barriers as per plans, in conjunction with NB 122975995. no change in use, egress or occupancy.
M00542467-I1
08/13/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/26/2026
Permit issued — Plumbing
M01414570-S1-PL
06/25/2026
Permit issued — General Construction
M01414570-I1-GC-CX
06/12/2026
Filed — Alteration
HEREBY FILING FOR RENOVATION OF COMMERCIAL SPACE (RANDYS). INSTALLATION OF PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01414570-S1
06/12/2026
Filed — Alteration
HEREBY FILING FOR RENOVATION OF COMMERCIAL SPACE (RANDYS). INSTALLATION OF PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01414570-I1
03/23/2026
Signed off — Alteration
M01066360-I1
03/23/2026
Signed off — Alteration
Tenant plumbing Fitout of retail space. No change in use, egress, or occupancy
M01066349-I1
03/12/2026
Signed off — Alteration
M01066268-I1
02/17/2026
Signed off — Alteration
INSTALL COMBINED SPRINKLER/STANDPIPE SYSTEM AS PER PLANS FILED HEREWITH. FILED IN CONJUNCTION WITH NB# 122975995.
M00602154-I1
01/15/2026
Signed off — Alteration
M01182266-I1
01/15/2026
Permit issued — Suspended Scaffold
M01182266-I1-SC
01/14/2026
Inspection — Pass-Final SP - More than 10 Requested Floors
Pass
View inspection ↗
01/05/2026
Inspection — Pass-Final SP - More than 10 Requested Floors
Pass
View inspection ↗
10/20/2025
Signed off — Alteration
Install temporary dry standpipe system during construction as per plans filed. No change to use, egress or occupancy. Filed in conjunction with NB# 122975995.
M00533962-I1
10/06/2025
Signed off — Alteration
M00529621-I1
09/22/2025
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
09/22/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/25/2025
Signed off — Alteration
NON-ILLUMINATED NON-ADVERTISING DOUBLE-FACE PROJECTING ACCESSORY SIGN - CLUB PILATES. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01175529-I1
03/04/2025
Permit issued — Sign
M01175529-I1-SG
03/02/2025
Filed — Alteration
NON-ILLUMINATED NON-ADVERTISING DOUBLE-FACE PROJECTING ACCESSORY SIGN - CLUB PILATES. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01175529-I1
02/28/2025
Signed off — Alteration
INSTALLATION OF CONSTRUCTION FENCE AS PER PLANS. CONSTRUCTION FENCE SHALL COMPLY WITH CHAPTER #33 OF THE 2014 CODE NO CHANGE TO USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION
M00251571-I1
02/27/2025
Special inspection requirement — Final
Richard Wainer
02/18/2025
Permit issued — Suspended Scaffold
M01182266-I1-SC
02/17/2025
Filed — Alteration
M01182266-I1
10/23/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/21/2024
Permit issued — Mechanical Systems
M01066360-I1-MS
10/21/2024
Permit issued — General Construction
M01066268-I1-GC
10/17/2024
Filed — Alteration
Tenant plumbing Fitout of retail space. No change in use, egress, or occupancy
M01066349-P1
10/17/2024
Special inspection requirement — Tenant Protection Plan Compliance
RICHARD GREENWALD
10/16/2024
Special inspection requirement — Tenant Protection Plan Compliance
10/07/2024
Permit issued — Plumbing
M01066349-I1-PL
09/12/2024
Signed off — Alteration
M00652694-I1
06/27/2024
Filed — Alteration
M01066268-I1
06/25/2024
Filed — Alteration
M01066360-I1
06/25/2024
Filed — Alteration
Tenant plumbing Fitout of retail space. No change in use, egress, or occupancy
M01066349-I1
02/29/2024
Signed off — Alteration
M00753396-I1
01/29/2024
Signed off — Alteration
Installation of temporary supported scaffold per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00731353-I1
01/29/2024
Signed off — Alteration
Installation of temporary scaffold as hoist runback structure per plan and application submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00661503-I1
01/29/2024
Signed off — Alteration
Installation of temporary windows protection/netting per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00657394-I1
01/29/2024
Signed off — Alteration
M00645416-I1
01/29/2024
Signed off — Alteration
Installation of temporary heavy duty sidewalk shed per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00645407-I1
01/29/2024
Signed off — Alteration
Installation of temporary overhead protection per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00657370-I1
01/29/2024
Signed off — Alteration
Installation of temporary roof protection per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00657348-I1
01/29/2024
Signed off — Alteration
Installation of 7,100# temporary dual car personnel/material hoists per plan and application submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00659879-I1
12/11/2023
Permit issued — Construction Fence
M00645416-I1-FN
12/11/2023
Permit issued — Sidewalk Shed
M00645407-I1-SH
12/01/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/14/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
11/10/2023
Filed — Alteration
INSTALL COMBINED SPRINKLER/STANDPIPE SYSTEM AS PER PLANS FILED HEREWITH. FILED IN CONJUNCTION WITH NB# 122975995.
M00602154-P2
11/09/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
RICHARD GREENWALD
11/09/2023
Special inspection requirement — Sprinkler Systems
RICHARD GREENWALD
11/09/2023
Special inspection requirement — Standpipe Systems
RICHARD GREENWALD
10/31/2023
Inspection — Pass-Final SP - More than 10 Requested Floors
Pass
View inspection ↗
Latest 60 of 237 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSignPermit IssuedUnitech Design09/25/2026
DOB NOWSuspended ScaffoldSigned-offTwo-Tone Contracting09/09/2026
DOB NOWPlumbingPermit IssuedAmerican Standard P&H Cororp06/26/2026
DOB NOWGeneral ConstructionPermit IssuedApn Builders06/25/2026
DOB NOWSuspended ScaffoldSigned-offTwo-Tone Contracting01/15/2026
DOB NOWSignSigned-offZ-Car-D03/04/2025
DOB NOWSuspended ScaffoldSigned-offTwo-Tone Contracting02/18/2025
DOB NOWMechanical SystemsSigned-offChristopher B. Mesbah10/21/2024
DOB NOWGeneral ConstructionSigned-offChristopher B. Mesbah10/21/2024
DOB NOWPlumbingSigned-offDonato Plumbing Group10/07/2024
DOB NOWConstruction FenceSigned-offColgate Enterprise12/11/2023
DOB NOWSidewalk ShedSigned-offColgate Enterprise12/11/2023
DOB NOWStandpipeSigned-offH M Sprinkler08/17/2023
DOB NOWSprinklersSigned-offH M Sprinkler08/17/2023
DOB NOWStandpipeSigned-offH M Sprinkler07/28/2023
DOB NOWPlumbingSigned-offDonato Plumbing Group05/11/2023
DOB NOWSupported ScaffoldSigned-offAndamio Scaffolding05/11/2023
DOB NOWConstruction FenceSigned-offChristopher B. Mesbah05/01/2023
DOB NOWSupported ScaffoldSigned-offColgate Enterprise04/27/2023
DOB NOWProtection and Mechanical MethodsSigned-offColgate Enterprise03/03/2023
DOB NOWStandpipeSigned-offH M Sprinkler02/17/2023
DOB NOWStandpipeSigned-offH M Sprinkler02/16/2023
DOB NOWSprinklersSigned-offH M Sprinkler02/16/2023
DOB NOWSupported ScaffoldSigned-offColgate Enterprise01/11/2023
DOB NOWProtection and Mechanical MethodsSigned-offColgate Enterprise01/09/2023
DOB NOWProtection and Mechanical MethodsSigned-offColgate Enterprise01/06/2023
DOB NOWProtection and Mechanical MethodsSigned-offColgate Enterprise01/06/2023
DOB NOWConstruction FenceSigned-offColgate Enterprise12/14/2022
DOB NOWSidewalk ShedSigned-offColgate Enterprise12/14/2022
DOB NOWProtection and Mechanical MethodsSigned-offDoria06/09/2022
DOB NOWSupported ScaffoldSigned-offAndamio Scaffolding05/10/2022
DOB NOWSupported ScaffoldSigned-offColgate Enterprise05/05/2022
DOB NOWSidewalk ShedSigned-offAndamio Scaffolding05/05/2022
DOB NOWConstruction FenceSigned-offChristopher B. Mesbah04/19/2022
DOB NOWProtection and Mechanical MethodsSigned-offColgate Enterprise03/18/2022
DOB NOWStandpipeSigned-offH M Sprinkler02/17/2022
DOB NOWSprinklersSigned-offH M Sprinkler02/17/2022
DOB NOWStandpipeSigned-offH M Sprinkler02/17/2022
DOB NOWProtection and Mechanical MethodsSigned-offMoncon02/14/2022
DOB NOWPlumbingSigned-offDonato Plumbing Group01/21/2022
+ 60 more permits on file
1 project · most recent 06/12/2026
Water/Sanitary
FiledStatusContractorScope
06/12/2026Permit IssuedAmerican Standard P&HWater/Sanitary
20 projects · most recent 09/24/2026
General Wiring
FiledStatusContractorScope
09/24/2026Permit IssuedAtmos Electric Svce—
06/26/2026Permit IssuedNion ElectricGeneral Wiring
11/13/2025CompleteModern Voltage NYC—
11/03/2025CompleteAE Electric—
09/15/2025CompleteAmber Electl Contng—
07/13/2025CompleteAccurate Electrical—
12/06/2024CompletePrudent Electric—
12/02/2024CompleteConde ElectricGeneral Wiring
10/02/2024CompleteAccurate Electrical—
05/21/2024CompleteContact ElectricGeneral Wiring
05/21/2024CompleteContact ElectricGeneral Wiring
05/21/2024CompleteContact Electric—
03/26/2024CompleteJam Electrical—
05/11/2023CompleteContact ElectricGeneral Wiring
08/03/2022CompleteBorowide Elect'l Contractors—
1 project · most recent 07/23/2021
Fence
FiledStatusContractorScope
07/23/2021Signed-offCM and Associates ConstructionFence
1 project · most recent 08/19/2026
Suspended Scaffold
FiledStatusContractorScope
08/19/2026Signed-offTwo-Tone ContractingSuspended Scaffold
1 project · most recent 08/19/2026
FiledStatusContractorScope
08/19/2026Signed-offTwo-Tone Contracting—
▾Field Inspections (DOB CAP) — 17
DateTypeResultReport
08/13/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/14/2026Pass-Final SP - More than 10 Requested FloorsPassView ↗
01/05/2026Pass-Final SP - More than 10 Requested FloorsPassView ↗
09/22/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
09/22/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/23/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/01/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
11/14/2023Pass-Final General Construction Non-Directive 14PassView ↗
10/31/2023Pass-Final SP - More than 10 Requested FloorsPassView ↗
10/26/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/26/2023Pass-Final SD - Fire PumpPassView ↗
10/23/2023Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
05/17/2023Pass-Final PL - UndergroundPassView ↗
03/30/2022Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
03/30/2022Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
12/30/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/09/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
09/11/2026FinalJUSTIN KIMprogress
02/27/2025FinalRichard Wainerprogress
10/17/2024Tenant Protection Plan ComplianceRICHARD GREENWALDspecial
10/16/2024Tenant Protection Plan Compliance—special
11/09/2023Fire-Resistant Penetrations and JointsRICHARD GREENWALDspecial
11/09/2023Sprinkler SystemsRICHARD GREENWALDspecial
11/09/2023Standpipe SystemsRICHARD GREENWALDspecial
12/23/2022Post-installed AnchorsSunil Saigalspecial
10/26/2022Post-installed AnchorsSunil Saigalspecial
07/27/2022Post-installed AnchorsSunil Saigalspecial
04/05/2022Structural Stability – Alterations of existing buildingsMD TOHFAZ UDDINspecial
04/05/2022Post-installed AnchorsMD TOHFAZ UDDINspecial
03/26/2022Post-installed AnchorsMD TOHFAZ UDDINspecial
03/26/2022Structural Stability – Alterations of existing buildingsMD TOHFAZ UDDINspecial
06/03/2021Standpipe SystemsRICHARD GREENWALDspecial
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Randy's DonutsRestaurant / Food ServiceFloor 1
Project M01459055 Alteration · Permit Entire · 09/24/2026
Project M01414570 Alteration · Permit Entire · 06/12/2026
Clue PilatesFitness / RecreationFloor 1
Project M01066268 Alteration · LOC Issued · 06/27/2024
Project M01066349 Alteration · LOC Issued · 06/25/2024
Project M01066360 Alteration · LOC Issued · 06/25/2024
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 556 on file (BIS + DOB NOW)
▸Plans & Drawings45
▸DOB NOWPlans/Sketch44
10/04/2026M01459055-I1Request digital key ↗
09/03/2026M00529621-I1Request digital key ↗
09/03/2026M00533962-I1Request digital key ↗
Showing 3 of 44 on file for this type
▸DOB NOWPlans/Sketch - Construction Fence1
09/05/2026M00251571-I1Request digital key ↗
▸Applications & Permits125
▸BISPLAN / WORK APPROVAL APPLICATION89
08/05/2025140618963Open ↗
07/31/2025120083532Open ↗
07/25/2025120087333Open ↗
Showing 3 of 89 on file for this type
▸BISWORK PERMIT APPLICATION33
03/13/2024122975995Open ↗
10/11/2023122975995Open ↗
10/10/2023122975995Open ↗
Showing 3 of 33 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation2
10/12/2023140618963Open ↗
07/01/2022140618963Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Zoning, Tax Lot & Property Records12
▸BISZONING DIAGRAM3
06/08/2023122975995Open ↗
02/03/2022122975995Open ↗
Showing 2 of 3 on file for this type
▸BISZONING RESOLUTION DETERMINATION2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT2
12/19/2023121253856Open ↗
Showing 1 of 2 on file for this type
▸BISEASEMENT AND RESTRICTIVE DECLARATIONS - SUPPPORTING DOCUMENTATION2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISZONING EXHIBIT I: CERTIFICATION2
12/19/2023121253856Open ↗
Showing 1 of 2 on file for this type
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
12/19/2023121253856Open ↗
▸Seals & Professional Certifications101
▸DOB NOWDPL-1: Design Professional Seal & Signature43
09/27/2026M01459055-I1Open ↗
09/03/2026M00529621-I1Open ↗
09/03/2026M00542467-I1Open ↗
Showing 3 of 43 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION24
01/28/2022122975995Open ↗
01/28/2022122975995Open ↗
Showing 2 of 24 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
08/31/2026M00661503-P1Open ↗
08/30/2026M00730971-P2Open ↗
08/29/2026M00602154-P2Open ↗
Showing 3 of 12 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
09/27/2023141024549Open ↗
12/21/2022141021864Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
09/27/2023141024549Open ↗
12/21/2022141021864Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
09/27/2023141024549Open ↗
12/21/2022141021864Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/01/2026M01175529-I1Open ↗
▸Trade Schedules & Equipment14
▸BISSCHEDULE B - PLUMBING6
02/08/2024122975995Open ↗
02/06/2024122975995Open ↗
12/13/2023122975995Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSEWER/HOUSE CON SIGNOFF: DEP HC 0212
01/05/2024122975995Open ↗
Showing 1 of 2 on file for this type
▸BISHEATING SYSTEMS1
12/19/2023122975995Open ↗
▸BISDEP SANITARY SEWER CERTIFICATION (HCP/SCP)1
01/05/2024122975995Open ↗
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
09/16/2024122975995Open ↗
▸BIS* SEWER CONNECTION: DEP SD1 & SD21
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Safety & Tenant Protection13
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISEXCAVATION - SHEETING, SHORING, AND BRACING2
04/12/2023122975995Open ↗
04/12/2023122975995Open ↗
▸BISSTREET TREE CHECKLIST2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos9
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Energy Compliance14
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS5
01/28/2022122975995Open ↗
Showing 1 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
01/04/2024122975995Open ↗
01/31/2022122975995Open ↗
01/27/2022122975995Open ↗
Showing 3 of 4 on file for this type
▸BISAIR SEALING AND INSULATION - VISUAL1
12/19/2023122975995Open ↗
▸BISINTERIOR LIGHTING POWER1
12/19/2023122975995Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
12/19/2023122975995Open ↗
▸BISEXTERIOR LIGHTING POWER1
12/19/2023122975995Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
12/19/2023122975995Open ↗
▸Inspections & Test Reports31
▸BISTECHNICAL REPORT: RESPONSIBILITY18
01/04/2024122975995Open ↗
01/09/2023122975995Open ↗
01/09/2023122975995Open ↗
Showing 3 of 18 on file for this type
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX7
02/25/2022122975995Open ↗
12/17/2021122975995Open ↗
12/17/2021122975995Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
03/17/2022122975995Open ↗
Showing 1 of 2 on file for this type
▸BISDEEP FOUNDATIONS / PILES1
04/12/2023122975995Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
01/23/2024122975995Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
01/23/2024122975995Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
07/05/2023122975995Open ↗
▸Approvals, Objections & Sign-offs70
▸BISLETTERS - SUPPORTING DOCUMENTATION15
12/20/2023121253856Open ↗
12/19/2023121253856Open ↗
12/19/2023121253856Open ↗
Showing 3 of 15 on file for this type
▸BISSUPERSEDING LETTER15
10/11/2023122975995Open ↗
10/10/2023122975995Open ↗
05/10/2023122975995Open ↗
Showing 3 of 15 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST14
08/13/2025141024549Open ↗
08/01/2025120083532Open ↗
07/31/2025120083532Open ↗
Showing 3 of 14 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE14
04/11/2024122975995Open ↗
12/20/2023122975995Open ↗
12/15/2023122975995Open ↗
Showing 3 of 14 on file for this type
▸BISADMINISTRATIVE OBJECTIONS9
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 9 on file for this type
▸BISTRANSIT AUTHORITY/MTA/PANYNJ APPROVAL2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISCONSTRUCTION CODE DETERMINATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Cost, Insurance & Ownership18
▸BISPROJECT-SPECIFIC GL INSURANCE11
03/13/2024122975995Open ↗
Showing 1 of 11 on file for this type
▸BISCOST AFFIDAVIT5
09/27/2023141024549Open ↗
12/21/2022141021864Open ↗
Showing 2 of 5 on file for this type
▸BISPROJECT SPECIFIC GENERAL LIABILITY INSURANCE2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Filing & Intake Forms47
▸BISADDITIONAL INFORMATION28
09/26/2025140618963Open ↗
04/16/2024122975995Open ↗
01/08/2024122975995Open ↗
Showing 3 of 28 on file for this type
▸BISEFILING COVER SHEET14
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 14 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
09/27/2023141024549Open ↗
12/21/2022141021864Open ↗
Showing 2 of 3 on file for this type
▸BISBOROUGH INTAKE FORM2
03/13/2024122975995Open ↗
Showing 1 of 2 on file for this type
▸Other Documents12
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISPLOT DIAGRAM3
12/19/2023121253856Open ↗
Showing 1 of 3 on file for this type
▸DOB NOWIRA Certification2
08/20/2026M01448517-I1Open ↗
08/13/2026M01182266-I1Open ↗
▸BISSHUTOFF DAMPERS1
02/22/2024122975995Open ↗