| Owner | Filings | Most Recent |
|---|---|---|
| JOANNE'S CONSTRUCTION CO | 1 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/12/2014 | $765K | — | — → — | $284/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| HC ARCHITECT, PC | 6 | 10/22/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| CH CORNERSTONE DESIGN | 6 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| JOANNE'S CONSTRUCTION CO | General Contractor | 8 | 07/08/2026 |
| AURA PLUMBING INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| INTERNATIONAL GEOTEHCNICA | 1795 | 2 | 10/22/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Foundation | Permit Issued | JOANNE'S CONSTRUCTION CO | 09/22/2025 |
| DOB NOW | Plumbing | Signed-off | AURA PLUMBING INC | 02/07/2025 |
| DOB NOW | Construction Fence | Signed-off | JOANNE'S CONSTRUCTION CO | 12/30/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | JOANNE'S CONSTRUCTION CO | 12/30/2024 |
| DOB NOW | Construction Fence | Signed-off | JOANNE'S CONSTRUCTION CO | 12/17/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | JOANNE'S CONSTRUCTION CO | 12/17/2024 |
| DOB NOW | Foundation | Permit Issued | JOANNE'S CONSTRUCTION CO | 10/02/2024 |
| DOB NOW | Construction Fence | Signed-off | JOANNE'S CONSTRUCTION CO | 09/24/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/22/2025 | Permit Issued | JOANNE'S CONSTRUCTION CO | Air Conditioning Systems, Heating Systems | Cooling Cooper & Hunter CH-06MASTWM-230VI 6,000 BTU · Ahu ×14 CH-HPR36M-230VO 36,000 BTU · Rooftop Unit ×6 CH-09MASTWM-230VI 9,000 BTU · Ahu ×4 CH-12 SPHWM-230VI 12,000 BTU · Ahu ×9 CH-36SPH-230VO 36,000 BTU · Rooftop Unit ×3 __Junk__ CH-18MOLVMN-230VI 18,000 BTU · Ahu ×6 Heating Cooper & Hunter CH-06MASTWM-230VI 6,000 BTU · Ahu ×14 CH-09MASTWM-230VI 9,000 BTU · Ahu ×4 CH-12 SPHWM-230VI 12,000 BTU · Ahu ×9 __Junk__ CH-18MOLVMN-230VI 18,000 BTU · Ahu ×6 Ducts & Piping |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/26/2025 | Complete | TESTA ELECTRIC CO., INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/22/2025 | Permit Issued | JOANNE'S CONSTRUCTION CO | Masonry, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/22/2025 | Permit Issued | JOANNE'S CONSTRUCTION CO | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 01/23/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 01/15/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 04/17/2025 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 02/18/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 02/18/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 01/02/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 01/02/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 12/30/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 12/22/2025 | Maintenance information | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 12/22/2025 | Fenestration areas | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 12/22/2025 | HVAC-R and service water heating equipment | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 12/22/2025 | Fenestration air leakage | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 12/22/2025 | HVAC-R and service water heating system controls | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 12/22/2025 | Protection of exposed foundation insulation | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 12/22/2025 | Fenestration and door U-factor and product ratings | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 12/22/2025 | HVAC-R and service water piping design and insulation | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 12/22/2025 | Interior lighting power | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 12/22/2025 | Insulation placement and R values | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 12/22/2025 | Footing and Foundation | MICHAEL KARANTINIDIS, P.E. | progress |
| 12/22/2025 | Final | MICHAEL KARANTINIDIS, P.E. | progress |
| 12/22/2025 | Structural Wood Frame | MICHAEL KARANTINIDIS, P.E. | progress |
| 12/22/2025 | Energy Code Compliance Inspections | MICHAEL KARANTINIDIS, P.E. | progress |
| 12/22/2025 | Fire-Resistance Rated Construction | MICHAEL KARANTINIDIS, P.E. | progress |
| 12/22/2025 | Exterior Insulation and Finish Systems (EIFS) | MICHAEL KARANTINIDIS, P.E. | special |
| 12/22/2025 | Mechanical Systems | MICHAEL KARANTINIDIS, P.E. | special |
| 12/22/2025 | Heating Systems | MICHAEL KARANTINIDIS, P.E. | special |
| 12/22/2025 | Structural Stability – Alterations of existing buildings | MICHAEL KARANTINIDIS, P.E. | special |
| 12/22/2025 | Fire-Resistant Penetrations and Joints | MICHAEL KARANTINIDIS, P.E. | special |
| 12/22/2025 | Masonry | MICHAEL KARANTINIDIS, P.E. | special |
| 12/22/2025 | Concrete - Cast-In-Place | MICHAEL KARANTINIDIS, P.E. | special |
| 12/22/2025 | Subgrade Inspections | MICHAEL KARANTINIDIS, P.E. | special |
| 10/03/2025 | Insulation placement and R values | MICHAEL KARANTINIDIS, P.E. | energy_progress |
| 10/03/2025 | Concrete - Cast-In-Place | MICHAEL KARANTINIDIS, P.E. | special |