← Back
One family attached or semi-detached
25-24 100 STREET
QUEENS · BIN 4032811
💬 Discuss this project
1959Year Built
2Stories
A5Building Class
R3-1Zoning
1,800 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
One family attached or semi-detached · 2,860 sf lot · 0.63 FAR built · Flood zone X
Locations of Work
Architecture
Floor 21p · 1 filing · 20 docs
Floor 12p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GERALD CALIENDO ARCHITECTS407/02/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GERALD J. CALIENDO R.A., P.C.703/21/2026
Building Lifecycle
All (58)Filed (4)Violation (1)Objection (38)Special Inspection (15)
08/26/2025
Special inspection requirement — Air barrier - visual inspection
08/26/2025
Special inspection requirement — Fenestration air leakage
08/26/2025
Special inspection requirement — Interior lighting power
08/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/26/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/26/2025
Special inspection requirement — Subgrade Inspections
08/26/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
08/26/2025
Special inspection requirement — Masonry
08/26/2025
Special inspection requirement — Energy Code Compliance Inspections
08/26/2025
Special inspection requirement — Fire-Resistance Rated Construction
08/26/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
08/26/2025
Special inspection requirement — Insulation placement and R values
08/26/2025
Special inspection requirement — Fenestration areas
07/28/2025
Objection resolved — Addressed
07/16/2025
Objection raised — Scope
07/02/2025
Filed — Alteration
Plumbing application for Q01059348-1.
Q01059348-P2
03/07/2025
Filed — Alteration
Plumbing application for Q01059348-1.
Q01059348-P1
01/27/2025
Filed — Alteration
Plumbing application for Q01059348-1.
Q01059348-S1
01/27/2025
Objection resolved — Addressed
01/22/2025
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
01/22/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/15/2025
Objection resolved — Addressed
01/02/2025
Objection resolved — Addressed
12/26/2024
Objection resolved — Addressed
12/26/2024
Objection resolved — Addressed
12/26/2024
Objection resolved — Addressed
12/26/2024
Objection resolved — Addressed
12/26/2024
Objection resolved — Addressed
12/06/2024
Objection resolved — Addressed
12/06/2024
Objection resolved — Addressed
12/06/2024
Objection resolved — Addressed
12/06/2024
Objection resolved — Addressed
12/06/2024
Objection resolved — Addressed
12/06/2024
Objection resolved — Addressed
12/06/2024
Objection resolved — Addressed
12/06/2024
Objection resolved — Addressed
12/06/2024
Objection resolved — Addressed
12/06/2024
Objection resolved — Addressed
09/17/2024
Objection raised — Scope
09/17/2024
Objection raised — Structural
09/12/2024
Objection raised — Other
09/12/2024
Objection raised — Fire_Protection
09/12/2024
Objection raised — Energy
09/12/2024
Objection raised — Structural
09/12/2024
Objection raised — Zoning
09/12/2024
Objection raised — Zoning
09/12/2024
Objection raised — Zoning
09/12/2024
Objection raised — Other
09/12/2024
Objection raised — Scope
09/12/2024
Objection raised — Inspections
09/12/2024
Objection raised — Zoning
09/12/2024
Objection raised — Zoning
09/12/2024
Objection raised — Admin
09/12/2024
Objection raised — Structural
09/12/2024
Objection raised — Zoning
09/12/2024
Objection raised — Zoning
07/22/2024
Filed — Alteration
Plumbing application for Q01059348-1.
Q01059348-I1
10/12/2007
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Nothing on file for this building.
1 project · most recent 07/02/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/02/2025——Gas, Storm, Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
08/26/2025Air barrier - visual inspection—energy_progress
08/26/2025Fenestration air leakage—energy_progress
08/26/2025Interior lighting power—energy_progress
08/26/2025Fire-Resistant Penetrations and Joints—special
08/26/2025Structural Stability – Alterations of existing buildings—special
08/26/2025Subgrade Inspections—special
08/26/2025Excavations - Sheeting, Shoring, and Bracing—special
08/26/2025Masonry—special
08/26/2025Energy Code Compliance Inspections—progress
08/26/2025Fire-Resistance Rated Construction—progress
08/26/2025Fenestration and door U-factor and product ratings—energy_progress
08/26/2025Insulation placement and R values—energy_progress
08/26/2025Fenestration areas—energy_progress
01/22/2025Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities—special
01/22/2025Fire-Resistant Penetrations and Joints—special
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026Q01059348-P2Request digital key ↗
08/21/2026Q01059348-P1Request digital key ↗
08/21/2026Q01059348-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026Q01059348-P2Open ↗
08/13/2026Q01059348-I1Open ↗
08/13/2026Q01059348-P1Open ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/21/2026Q01059348-I1Open ↗
08/21/2026Q01059348-P2Open ↗
08/21/2026Q01059348-P1Open ↗
Showing 3 of 4 on file for this type
▸Other Documents9
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026Q01059348-I1Open ↗
08/13/2026Q01059348-P1Open ↗
08/13/2026Q01059348-P2Open ↗
▸DOB NOWPlot Diagram3
08/13/2026Q01059348-P1Open ↗
08/13/2026Q01059348-I1Open ↗
08/13/2026Q01059348-P2Open ↗
▸DOB NOWSite Survey: Initial3
08/13/2026Q01059348-P1Open ↗
08/13/2026Q01059348-P2Open ↗
08/13/2026Q01059348-I1Open ↗