25-30 18 STREET
QUEENS · BIN 4020518
💬 Discuss this project
1920Year Built
3Stories
C0Building Class
R6BZoning
2,709 sfGross Floor Area
3Units
Rent Stabilized3 Open Violations ▸
Three families · 2,500 sf lot · 1.08 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction9p · 1 filing · 17 docs
Floor 3Under Construction15p · 1 filing · 17 docs
Floor 2Under Construction15p · 1 filing · 17 docs
Floor 1Under Construction15p · 1 filing · 17 docs
CellarUnder Construction14p · 1 filing · 17 docs
Sub-BasementUnder Construction5p · 1 filing · 17 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/27/2025$1.6M—— → —$594/sf building
07/13/2020$1.6M—Private party → Private party$591/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CUSTOM DESIGNING & ENGINEERING209/23/2025
N/A209/22/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A+ EXPEDITING803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BUILDWISE CONSTRUCTION GRGeneral Contractor304/09/2026
BEST PLUMBING & HVAC INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD TESTING & INSPECTION S7010409/23/2025
Building Lifecycle
All (56)Filed (4)Permit Issued (4)Violation (23)Objection (14)Special Inspection (11)
05/06/2026
Violation issued (HPD, open)
A
04/23/2026
Permit issued — Plumbing
Q01230334-S1-PL
04/01/2026
Objection resolved — Addressed
04/01/2026
Objection resolved — Addressed
03/02/2026
Permit issued — Mechanical Systems
Q01230334-S3-MS
02/26/2026
Permit issued — General Construction
Q01230334-I1-GC
02/25/2026
Permit issued — Structural
Q01230334-S2-ST
02/05/2026
Objection raised — Plumbing
02/05/2026
Objection raised — Plumbing
01/22/2026
Objection resolved — Addressed
01/22/2026
Objection resolved — Addressed
01/22/2026
Objection resolved — Addressed
01/16/2026
Objection raised — Scope
01/06/2026
Objection resolved — Addressed
12/02/2025
Objection raised — Admin
12/02/2025
Objection resolved — Addressed
11/21/2025
Violation issued (HPD, open)
I
10/20/2025
Objection raised — Other
10/17/2025
Objection raised — Scope
10/17/2025
Objection raised — Cost
09/23/2025
Filed — Alteration
Mechanical in conjunction with i1 for construction to install 4 split HVAC units with condensers on the roof; Bathroom and Utility Room Ventilation; Ceiling Hung Heaters
Q01230334-S3
09/23/2025
Filed — Alteration
Mechanical in conjunction with i1 for construction to install 4 split HVAC units with condensers on the roof; Bathroom and Utility Room Ventilation; Ceiling Hung Heaters
Q01230334-S1
09/22/2025
Filed — Alteration
Mechanical in conjunction with i1 for construction to install 4 split HVAC units with condensers on the roof; Bathroom and Utility Room Ventilation; Ceiling Hung Heaters
Q01230334-I1
09/22/2025
Filed — Alteration
Mechanical in conjunction with i1 for construction to install 4 split HVAC units with condensers on the roof; Bathroom and Utility Room Ventilation; Ceiling Hung Heaters
Q01230334-S2
09/11/2025
Special inspection requirement — Energy Code Compliance Inspections
XIUCHENG LI
09/11/2025
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
XIUCHENG LI
08/22/2025
Special inspection requirement — Wood – Seismic Resistance
XIUCHENG LI
08/22/2025
Special inspection requirement — Structural Wood Frame
XIUCHENG LI
08/22/2025
Special inspection requirement — Concrete - Cast-In-Place
XIUCHENG LI
06/11/2025
Violation issued (HPD, open)
A
05/29/2025
Special inspection requirement — HVAC-R and service water heating equipment
XIUCHENG LI
05/29/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
XIUCHENG LI
05/29/2025
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
05/23/2025
Special inspection requirement — Final
XIUCHENG LI
05/23/2025
Special inspection requirement — Mechanical Systems
XIUCHENG LI
05/23/2025
Special inspection requirement — Final
XIUCHENG LI
01/21/2025
Violation issued (HPD, closed)
C
01/21/2025
Violation issued (HPD, closed)
B
01/21/2025
Violation issued (HPD, closed)
C
04/12/2024
Violation issued (HPD, closed)
A
11/22/2023
Violation issued (HPD, closed)
I
03/27/2023
Violation issued (HPD, closed)
A
11/15/2022
Violation issued (HPD, closed)
I
03/02/2022
Violation issued (HPD, closed)
A
04/14/2021
Violation issued (HPD, closed)
A
09/14/2020
Violation issued (HPD, closed)
B
09/14/2020
Violation issued (HPD, closed)
A
09/14/2020
Violation issued (HPD, closed)
B
09/14/2020
Violation issued (HPD, closed)
A
09/14/2020
Violation issued (HPD, closed)
A
09/14/2020
Violation issued (HPD, closed)
C
09/14/2020
Violation issued (HPD, closed)
A
09/14/2020
Violation issued (HPD, closed)
A
09/14/2020
Violation issued (HPD, closed)
C
09/14/2020
Violation issued (HPD, closed)
C
07/20/2017
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedBEST PLUMBING & HVAC INC04/23/2026
DOB NOWMechanical SystemsPermit IssuedBUILDWISE CONSTRUCTION GR03/02/2026
DOB NOWGeneral ConstructionPermit IssuedBUILDWISE CONSTRUCTION GR02/26/2026
DOB NOWStructuralPermit IssuedBUILDWISE CONSTRUCTION GR02/25/2026
1 project · most recent 09/23/2025
Air Conditioning Systems Heating Systems Others
FiledStatusContractorScopeMake / Model / Capacity
09/23/2025Permit IssuedBUILDWISE CONSTRUCTION GRAir Conditioning Systems, Heating Systems, Others
Cooling
Carrier 38MGRQ36D-3 4,500 CFM · Split System ×3
38MGRQ30D-3 2,130 CFM · Split System ×1
Heating
Markel 3000 SERIES- E3038DWBW 100 CFM · Unit Heater ×1
3380 SERIES- F3387D-RP 175 CFM · Unit Heater ×1
Other
Pennbarry Z5H- 128 CFM · Exhaust Fan ×3
Z5H 128 CFM · Exhaust Fan ×2
Penn Barry Z5H 128 CFM · Exhaust Fan ×4
1 project · most recent 09/23/2025
Gas Water/Sanitary
FiledStatusContractorScope
09/23/2025Permit IssuedBEST PLUMBING & HVAC INCGas, Water/Sanitary
1 project · most recent 03/03/2026
General Wiring
FiledStatusContractorScope
03/03/2026Permit IssuedINTELOGIC ELECTRIC, INC.General Wiring
1 project · most recent 09/23/2025
Wood
FiledStatusContractorScope
09/23/2025Permit IssuedBEST PLUMBING & HVAC INCWood
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
09/11/2025Energy Code Compliance InspectionsXIUCHENG LIprogress
09/11/2025Construction Utilizing CLT or SCL, Type IVXIUCHENG LIspecial
08/22/2025Wood – Seismic ResistanceXIUCHENG LIspecial
08/22/2025Structural Wood FrameXIUCHENG LIprogress
08/22/2025Concrete - Cast-In-PlaceXIUCHENG LIspecial
05/29/2025HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
05/29/2025HVAC-R and service water piping design and insulationXIUCHENG LIenergy_progress
05/29/2025HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
05/23/2025FinalXIUCHENG LIprogress
05/23/2025Mechanical SystemsXIUCHENG LIspecial
05/23/2025FinalXIUCHENG LIprogress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/18/2026Q01230334-S2Request digital key ↗
08/18/2026Q01230334-I1Request digital key ↗
08/18/2026Q01230334-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/13/2026Q01230334-I1Open ↗
08/13/2026Q01230334-S2Open ↗
08/13/2026Q01230334-S3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/23/2026Q01230334-S3Open ↗
09/23/2026Q01230334-S3Open ↗
08/29/2026Q01230334-S2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026Q01230334-S3Open ↗
08/29/2026Q01230334-S2Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026Q01230334-S2Open ↗
08/13/2026Q01230334-S1Open ↗
08/13/2026Q01230334-I1Open ↗
Showing 3 of 4 on file for this type