← Back
Two family converted from one family
25-57 97 STREET
QUEENS · BIN 4032710
💬 Discuss this project
1955Year Built
2Stories
B3Building Class
R3-2Zoning
1,640 sfGross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸
Two family converted from one family · 1,950 sf lot · 0.84 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
H G LEE ARCHITECT PC101/30/2025
TECHNEMOTION DESIGN106/23/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
VIOLATION REMOVAL103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEW CENTURY ELEC'L CONTRElectrical103/22/2026
Building Lifecycle
All (45)Filed (2)Violation (28)Objection (4)Special Inspection (11)
01/30/2025
Filed — Alteration
ALTERATION HEREWITH FILED FOR A NEW CMU WALL FENCE 6FT. HT. . NO CHANGE IN USE,EGRESS, OR OCCUPANCY.
Q01160902-I1
12/29/2024
Special inspection requirement — Concrete - Cast-In-Place
12/29/2024
Special inspection requirement — Masonry
12/29/2024
Special inspection requirement — Final
12/29/2024
Special inspection requirement — Footing and Foundation
12/13/2024
Violation issued (ECB, open)
Construction
07/09/2021
Objection raised — Scope
07/09/2021
Objection resolved — Addressed
07/09/2021
Objection raised — Zoning
07/09/2021
Objection resolved — Addressed
06/23/2021
Filed — Alteration
FILED TO ADDRESS VIOLATION # 35413954Y, REMOVE FRONT GARAGE EXTENSION & RESTORE GARAGE DOOR TO ORIGINAL CONDITION, AND REDUCE SIZE OF STORAGE SHED @REAR YARD TO COMPLY WITH APPLICABLE RCNY LAW. AS PER PLANS NO CHANGE IN USE EGRESS OR ANY OCCUPANCY.
Q00500112-I1
06/08/2021
Violation issued (ECB, closed)
Construction
05/18/2021
Violation issued (ECB, closed)
Construction
05/14/2021
Special inspection requirement — Energy Code Compliance Inspections
04/07/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/07/2021
Special inspection requirement — Final
04/07/2021
Special inspection requirement — Insulation placement and R values
04/07/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
04/07/2021
Special inspection requirement — Fenestration air leakage
04/07/2021
Special inspection requirement — Air barrier - visual inspection
03/12/2021
Violation issued (ECB, closed)
Construction
03/12/2021
Violation issued (ECB, closed)
Construction
03/12/2021
Violation issued (ECB, closed)
Construction
03/12/2021
Violation issued (ECB, closed)
Construction
12/31/2020
Violation issued (ECB, closed)
Construction
12/31/2020
Violation issued (ECB, closed)
Construction
12/31/2020
Violation issued (ECB, closed)
Construction
12/31/2020
Violation issued (ECB, closed)
Construction
12/18/2020
Violation issued (ECB, closed)
Construction
09/08/2020
Violation issued (ECB, closed)
Construction
09/08/2020
Violation issued (ECB, closed)
Construction
09/08/2020
Violation issued (ECB, closed)
Construction
09/08/2020
Violation issued (ECB, closed)
Construction
09/08/2020
Violation issued (ECB, closed)
Construction
09/08/2020
Violation issued (ECB, closed)
Construction
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/04/2020
Violation issued (ECB, closed)
Quality of Life
02/04/2020
Violation issued (ECB, closed)
Quality of Life
02/04/2020
Violation issued (ECB, closed)
Construction
02/04/2020
Violation issued (ECB, closed)
Construction
02/04/2020
Violation issued (ECB, closed)
Construction
02/04/2020
Violation issued (ECB, closed)
Quality of Life
06/13/2017
Violation issued (ECB, closed)
Zoning
Nothing on file for this building.
1 project · most recent 12/04/2020
General Wiring
FiledStatusContractorScope
12/04/2020Permit IssuedNEW CENTURY ELEC'L CONTRGeneral Wiring
1 project · most recent 01/30/2025
FiledStatusContractorScope
01/30/2025——1 scope_items
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
12/29/2024Concrete - Cast-In-Place—special
12/29/2024Masonry—special
12/29/2024Final—progress
12/29/2024Footing and Foundation—progress
05/14/2021Energy Code Compliance Inspections—progress
04/07/2021Fire-Resistant Penetrations and Joints—special
04/07/2021Final—progress
04/07/2021Insulation placement and R values—energy_progress
04/07/2021Fenestration and door U-factor and product ratings—energy_progress
04/07/2021Fenestration air leakage—energy_progress
04/07/2021Air barrier - visual inspection—energy_progress
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01160902-I1Request digital key ↗
08/15/2026Q00500112-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/27/2026Q00500112-I1Open ↗
08/13/2026Q01160902-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/15/2026Q00500112-I1Open ↗