← Back
Two family brick
25-68 34 STREET
QUEENS · BIN 4009313
💬 Discuss this project
1920Year Built
2Stories
B1Building Class
R6BZoning
2,244 sfGross Floor Area
2Units
Two family brick · 1,940 sf lot · 1.16 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction4p · 1 filing · 18 docs
Floor 1Under Construction4p · 1 filing · 18 docs
CellarUnder Construction4p · 1 filing · 18 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/12/2024$1.5M—— → —$668/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ENVIRONMENTAL MANAGEMENT SERVICES,412/23/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BRODURE LLCGeneral Contractor104/09/2026
BMT PLUMBING&HEATING LLCPlumbing107/08/2026
GERARD'S PLBG & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENVIRONMENTAL MANAGEMENT1375412/23/2024
Building Lifecycle
All (34)Filed (4)Permit Issued (3)Inspection (3)Special Inspection (24)
01/20/2026
Permit issued — Plumbing
Q01032125-S1-PL
01/20/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/20/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kosta Kamberis
01/20/2025
Special inspection requirement — Maintenance information
Kosta Kamberis
01/20/2025
Special inspection requirement — HVAC-R and service water heating equipment
Kosta Kamberis
01/20/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Kosta Kamberis
01/20/2025
Special inspection requirement — HVAC-R and service water heating system controls
Kosta Kamberis
01/20/2025
Special inspection requirement — Energy Code Compliance Inspections
Kosta Kamberis
12/23/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING 2 FAMILY BLDG WITH CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q01032125-P2
12/23/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING 2 FAMILY BLDG WITH CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q01032125-P3
12/23/2024
Special inspection requirement — Air barrier - visual inspection
Kosta Kamberis
12/23/2024
Special inspection requirement — Metering
Kosta Kamberis
12/23/2024
Special inspection requirement — Fenestration air leakage
Kosta Kamberis
12/23/2024
Special inspection requirement — Air barrier — testing
Kosta Kamberis
12/23/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Kosta Kamberis
12/23/2024
Special inspection requirement — Fenestration areas
Kosta Kamberis
12/23/2024
Special inspection requirement — Interior lighting power
Kosta Kamberis
12/23/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kosta Kamberis
12/23/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kosta Kamberis
12/23/2024
Special inspection requirement — Final
Kosta Kamberis
12/23/2024
Special inspection requirement — Fire-Resistance Rated Construction
Kosta Kamberis
12/23/2024
Special inspection requirement — Energy Code Compliance Inspections
Kosta Kamberis
12/18/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Kosta Kamberis
12/18/2024
Special inspection requirement — Maintenance information
Kosta Kamberis
12/18/2024
Special inspection requirement — HVAC-R and service water heating equipment
Kosta Kamberis
12/18/2024
Special inspection requirement — HVAC-R and service water heating system controls
Kosta Kamberis
12/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Kosta Kamberis
12/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kosta Kamberis
08/15/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/17/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/03/2024
Permit issued — Plumbing
Q01032125-S1-PL
06/12/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING 2 FAMILY BLDG WITH CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q01032125-S1
04/16/2024
Permit issued — General Construction
Q01032125-I1-GC
04/13/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING 2 FAMILY BLDG WITH CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q01032125-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedBMT PLUMBING&HEATING LLC01/20/2026
DOB NOWPlumbingPermit IssuedGERARD'S PLBG & HTG CORP07/03/2024
DOB NOWGeneral ConstructionSigned-offBRODURE04/16/2024
1 project · most recent 12/23/2024
Gas Water/Sanitary
FiledStatusContractorScope
12/23/2024Permit IssuedGBL MECHANICAL GROUP INCGas, Water/Sanitary
1 project · most recent 07/05/2024
General Wiring
FiledStatusContractorScope
07/05/2024CompleteATTRACTIVE LIGHTING ELECLGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
01/20/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/15/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/17/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
01/20/2025Fire-Resistant Penetrations and JointsKosta Kamberisspecial
01/20/2025Maintenance informationKosta Kamberisenergy_progress
01/20/2025HVAC-R and service water heating equipmentKosta Kamberisenergy_progress
01/20/2025HVAC-R and service water piping design and insulationKosta Kamberisenergy_progress
01/20/2025HVAC-R and service water heating system controlsKosta Kamberisenergy_progress
01/20/2025Energy Code Compliance InspectionsKosta Kamberisprogress
12/23/2024Air barrier - visual inspectionKosta Kamberisenergy_progress
12/23/2024MeteringKosta Kamberisenergy_progress
12/23/2024Fenestration air leakageKosta Kamberisenergy_progress
12/23/2024Air barrier — testing Kosta Kamberisenergy_progress
12/23/2024Fenestration and door U-factor and product ratingsKosta Kamberisenergy_progress
12/23/2024Fenestration areasKosta Kamberisenergy_progress
12/23/2024Interior lighting powerKosta Kamberisenergy_progress
12/23/2024Fire-Resistant Penetrations and JointsKosta Kamberisspecial
12/23/2024Structural Stability – Alterations of existing buildingsKosta Kamberisspecial
12/23/2024FinalKosta Kamberisprogress
12/23/2024Fire-Resistance Rated ConstructionKosta Kamberisprogress
12/23/2024Energy Code Compliance InspectionsKosta Kamberisprogress
12/18/2024HVAC-R and service water piping design and insulationKosta Kamberisenergy_progress
12/18/2024Maintenance informationKosta Kamberisenergy_progress
12/18/2024HVAC-R and service water heating equipmentKosta Kamberisenergy_progress
12/18/2024HVAC-R and service water heating system controlsKosta Kamberisenergy_progress
12/18/2024Energy Code Compliance InspectionsKosta Kamberisprogress
12/18/2024Fire-Resistant Penetrations and JointsKosta Kamberisspecial
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026Q01032125-P2Request digital key ↗
08/21/2026Q01032125-S1Request digital key ↗
08/21/2026Q01032125-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/21/2026Q01032125-S1Open ↗
08/21/2026Q01032125-I1Open ↗
08/21/2026Q01032125-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/27/2026Q01032125-I1Open ↗
08/27/2026Q01032125-I1Open ↗
08/24/2026Q01032125-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/27/2026Q01032125-I1Open ↗
08/24/2026Q01032125-P2Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/21/2026Q01032125-S1Open ↗
08/21/2026Q01032125-I1Open ↗
08/21/2026Q01032125-P3Open ↗
Showing 3 of 4 on file for this type