← Back
Five to six families
25-75 45 STREET
QUEENS · BIN 4012774
💬 Discuss this project
1928Year Built
3Stories
C2Building Class
R5Zoning
3,900 sfGross Floor Area
6Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Five to six families · 2,500 sf lot · 1.56 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BOULIS CONSTRUCTION503/22/2026
TOPLINE NYC CONTRACTING303/22/2026
ALVAREZ103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/27/2014$1.2M—— → —$313/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MJE PROFESSIONAL SERVICES106/01/2023
ASR ENGINEERING PC105/24/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ADVANCED BUILDERS SERVICES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TOPLINE NYC CONTRACTINGGeneral Contractor303/21/2026
BOULIS CONSTRUCTION CORPGeneral Contractor203/21/2026
TESLA ELECTRIC CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BANGASH ASSOCIATES INC8488106/01/2023
Building Lifecycle
All (12)Filed (2)Permit Issued (2)Signed Off (1)Violation (2)Special Inspection (5)
08/24/2023
Signed off — Alteration
FACADE REPAIR, POINTING AND BRICK REPLACEMENT AS PER PLAN. THERE WILL BE NO CHANGE IN THE USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
Q00884042-I1
06/06/2023
Permit issued — General Construction
Q00884042-I1-GC
06/01/2023
Filed — Alteration
FACADE REPAIR, POINTING AND BRICK REPLACEMENT AS PER PLAN. THERE WILL BE NO CHANGE IN THE USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
Q00884042-I1
06/01/2023
Special inspection requirement — Masonry
FAZAL BANGASH
06/01/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAZAL BANGASH
06/01/2023
Special inspection requirement — Tenant Protection Plan Compliance
FAZAL BANGASH
06/01/2023
Special inspection requirement — Final
FAZAL BANGASH
06/01/2023
Special inspection requirement — Energy Code Compliance Inspections
FAZAL BANGASH
05/24/2023
Filed — Alteration
Q00879212-I1
05/24/2023
Permit issued — Sidewalk Shed
Q00879212-I1-SH
03/28/2023
Violation issued (HPD, closed)
A
10/01/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offBOULIS CONSTRUCTION CORP06/06/2023
DOB NOWSidewalk ShedPermit IssuedTOPLINE NYC CONTRACTING05/24/2023
BISBLISSUEDGLOBE FUEL OIL CO.05/13/1992
2 projects · most recent 05/26/2023
General Wiring
FiledStatusContractorScope
05/26/2023Permit IssuedRICHARD NEU—
11/24/2020CompleteTESLA ELECTRIC CORPGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
06/01/2023MasonryFAZAL BANGASHspecial
06/01/2023Structural Stability – Alterations of existing buildingsFAZAL BANGASHspecial
06/01/2023Tenant Protection Plan ComplianceFAZAL BANGASHspecial
06/01/2023FinalFAZAL BANGASHprogress
06/01/2023Energy Code Compliance InspectionsFAZAL BANGASHprogress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026Q00879212-I1Request digital key ↗
08/24/2026Q00884042-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026Q00879212-I1Open ↗
08/13/2026Q00884042-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/20/2026Q00884042-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/20/2026Q00884042-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q00884042-I1Open ↗