ECB10/24/2026At time of inspection, observed inactive jobsite with building footprint over 5,000 sf and no watchperson, contrary to bc 3303.3. Knocked and called out with no response. Contacted site watch security, which ad$2K due
ECB10/24/2026At time of inspection, observed jersey barriers occupying the roadway and construction fence occupying the sidewalk. Upon review of DOT records, no occupancy permits were found, contrary to bc 3307.2.1, creatin$2K due
ECB02/03/2026Upon inspection i observed a shed installed at exposure 1&2 not no sidewalk shed info panel installed contrary to code 3301.9.2 sidewalk shed parapet information panel. I also observed a construction fence inst$1K due
ECB02/03/2026I observed a sidewalk shed installed at expos 1&2 and upon review of approved drawings it was determined the shed was installed contrary to the plans. Missing double headers at all spans over 10FT. Incorrect cr$1K due
ECB02/03/2026I observed a sidewalk shed installed at exposure 1&2 contrary to code. Minimum 8FT height not maintained at corner of expos 1&2, pipes set below 8FT across pathway (3307.6.4.7 height). Shed bracing and jersey b$2K due
ECB02/03/2026Upon inspection i observed a sidewalk shed installed at expos 1&2 not maintained contrary to code 3307.6.5.1 safe condition. Un-protected bolts & tops of kickers along shed pathway (expo 1&2), rotting mudsills$2K due
ECB07/31/2025Observation: model aparments on 3RD/4TH floor being shown to perspective buyers. Apartments were completely furnished. To get to model apts,perspective buyers has to walk thru a lobby under active construction$6K due