DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
ECB06/18/2025REISSUE #35684999M DATE OF ISSUE: 10-01-2024. ALTERED/CHANGED BUILDINGOCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1-28-118.3.2. AT THE TIME OF INSPECTION OBSERVED AND NOTED NEW 4 STORY ADDNothing owed — awaiting certificate of correction
ECB06/18/2025REISSUE #35684997Z DATE OF ISSUE: 10-01-2024. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED AT STAIR "D" BULKHEAD HAS AN APPROX 3FTX8FT SECTION OF PLASTER MNothing owed — awaiting certificate of correction
ECB06/18/2025REISSUE #3564996R DATE OF ISSUE: 10-01-2024. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED AT CLASS ROOM DOORS WITH DEFECTIVE/MISSING DOOR CLOSERS AT OLD WINothing owed — awaiting certificate of correction
ECB06/18/2025EXIT DOOR NOT SELF-CLOSING PROPERLY AT THE TIME OF INSPECTION AT THE TIME OF INSPECTION OBSERVED AND NOTED AT 3RD FLOOR NEAR ROOM NO-321 ONECORRIDOR EXIT DOOR NOT SELF-CLOSING PROPERLY, AT 1ST FLOOR PLAY AREA ENothing owed — awaiting certificate of correction
ECB06/18/2025REISSUE #35683995P DATE OF ISSUE: 10-01-2024. FAILURE TO MAINTAIN BUILDINGIN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. AT THE TIME OF INSPECTIONNothing owed — awaiting certificate of correction
ECB10/01/2024REISSUE #35676303P. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: CLASSROOM DOORS WITH DEFECTIVE/MISSING CLOSERS AT OLD WINGROOM #317, 315, 313, 311, 329, 327, 305, 256A AND 262. ALSO FDSC DOORNothing owed — awaiting certificate of correction
ECB10/01/2024ALTERED/CHANEGED BUILDING WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1-28-118.3.2. NOTED NEW 4 STORY ADDITION TO THE SCHOOL BYSTUDENTS, TEACHERS AND STAFF TCO #2129029-08 EXPIRED ON 08/01/2023. NONothing owed — awaiting certificate of correction
ECB10/01/2024REISSUE #35676304R. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED STAIR D BULHEAD HAS AN APPROX 3FTX8FT SECTION OF PLANTER MISSING ON CEILING AND CRUMBLING, SPALLING/CRACKING PLASTER ON WALLS DUENothing owed — awaiting certificate of correction
ECB10/01/2024REISSUE #35676305Z. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER 1006.1; 27-381. NOTED EMERGENCY LIGHTS NOT WORKING WHEN TESTED AT 2NDNothing owed — awaiting certificate of correction
ECB06/30/2023REISSUE #35665118J DATE OF ISSUE:07.21.22 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED MISSING DOOR SELF CLOSERS AT OLD BUILDING ROOM NO. 317,315,313,309,3Nothing owed — awaiting certificate of correction
ECB06/30/2023REISSUE #35591730R DATE OF ISSUE:08.24.2021 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381 AT THE TIME OF INSPECTION OBSENothing owed — awaiting certificate of correction
ECB06/30/2023REISSUE #35665117H DATE OF ISSUE:07.21.2023 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT THE TIME OF INSPECTION NOTED AT BULKHEAD STAIR WAY "D" CEILING LEADING TO THE BULKHEAD DAMAGED DUE TO WATERNothing owed — awaiting certificate of correction
ECB07/21/2022RE-ISSUED #35591732K-FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:(BULKHEAD)STAIRWAY D CEILING BULGING/DAMAGED DUE TO WATER PENETRATIONS COMING FROM ABOVE APROX 3FT X 3FT SECTION OF CEILING IN DINothing owed — awaiting certificate of correction
ECB07/21/2022RE-ISSUED #35591731Z-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED MISSING SELF-CLOSER HARDWARE AT CLASSROOM DOORS #317 #315 #313 #311 #309 #307 #305 & 2ND FLOOR CLASSROOM #262.REMEDY:REPNothing owed — awaiting certificate of correction
ECB08/24/2021REISSUED#35500804Y FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED:MISSING DOOR SELF CLOSERS AT ROOM 317,315,313,311,309,307,305256A AND 262.REM:REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB08/24/2021FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION PERBC 1006.1;27-381.NOTED:AT CAFETERIA EMERGENCY LIGHT#2 AT 1ST FLOOR ABOVE STAIRWAY DOOR D EMERGENCY LIGHT AT 1ST FLOOR NEXT TO EXIT 1 EMERGENNothing owed — awaiting certificate of correction
ECB08/24/2021REISSUED#35500802K FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED AT STAIR D LEADING TO BULKHEAD CEILING IS DISREPAIR WITH MISSING OF A SECTION OF CEILING PLASTER APPROX 3'X3'DUE TO WATER PENETRATINothing owed — awaiting certificate of correction
ECB06/16/2020FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED OBSERVED CLASSROOM DOORS AT 3RD FLOOR ROOM 317,315 ,313,311,309,307,305,2ND FLOR ROOM 256A 262 AND FIRE PRROF SELF CLOSING DOOR #1 BY EXIT 1 ARE NOTNothing owed — awaiting certificate of correction
ECB06/16/2020FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTE OBSERVED THE STAIRCASE CEILING IN STAIR D LEADING TO THE BULKHEAD DOOR HAS WATER PENETRATING LEADING TO SPALLING PLASTER REPAIR AND OR REPLACENothing owed — awaiting certificate of correction
Public elementary, junior or senior high · Owner of record: NYC DEPARTMENT OF EDUCATION · 85,000 sf lot · 1.15 FAR built · Flood zone X