HPD04/13/2026§ 27-2056.4(h) and 27-2056.17 ADM code -correct failure to provide to the department within 45 days of demand all records required to be maintained by owner pursuant to local law 1 of 2004 related to lead-based paint notices, inspections and remediation/abatement activities.
HPD04/13/2026§ 27-2056.4 ADM code- correct failure to notify occupants and/or to investigate lead-based paint hazards.
HPD12/24/2025§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 3rd ROOM FROM EAST AT SOUTH, THE 2nd ROOM FROM EAST, THE BATHROOM LOCATED AT APT 2K, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH
HPD12/24/2025§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT APT 2K, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH
HPD12/24/2025§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st DOOR FRAME FROM NORTH AT EAST WALL, 1st DOOR FROM NORTH AT EAST WALL IN THE FOYER LOCATED AT APT 2K, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH
HPD12/24/2025§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL IN THE KITCHEN LOCATED AT APT 2K, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH
HPD12/24/202528 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AND SILL AT .. IN THE ENTRANCE LOCATED AT APT 2K, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH
HPD12/24/2025§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRE AT WEST WALL IN THE KITCHEN LOCATED AT APT 2K, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH
HPD11/01/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCK AND ASSEMBLY AT APT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH''
HPD11/01/2025§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
HPD11/01/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AND ASSEMBLY AT APT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH''
HPD11/01/2025§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
HPD10/10/2025§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT CEILING AT PUBLIC HALL, 1st STORY
HPD06/25/2025§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCKABLE HASP AND EYE AT GATE AT 1ST WINDOW FROM NORTH AT EAST WALL (FIRE ESCAPE) IN THE 4th ROOM FROM NORTH LOCATED AT APT 1I, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD06/25/2025§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF A KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO FIRE ESCAPE WINDOW IN THE 4th ROOM FROM NORTH LOCATED AT APT 1I, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD06/25/2025§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE .. IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
HPD04/14/2025§ 27-2005, 2007 ADM code and dept. Rules and regulations. Remove the encumbrance obstructing egress from fire escapes consisting of flower pots at 4TH story balcony at 1ST stack from north at west exterior wall at fire escape
HPD03/17/2025§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD12/10/2023§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
HPD12/10/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
HPD12/10/2023§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
HPD03/17/2023§ 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''2500'', AT NORTH
HPD03/17/2023§ 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''2500'', AT NORTH
HPD02/28/2023§ 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 1J, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD02/28/2023§ 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 5I, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''2500'', AT SOUTH
HPD02/23/2023§ 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE RADIATOR SHUT OFF VALVE IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD01/04/2023§ 27-2056.4 ADM code- correct failure to notify occupants and/or to investigate lead-based paint hazards.
HPD01/04/2023§ 27-2056.7 ADM code: correct failure to provide to the department within 45 days of demand all records required to be maintained by owner pursuant to local law 1 of 2004 related to lead-based paint notices, inspections and remediation/abatement activities.
HPD11/03/2022HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD03/24/2021§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP DOWN CELING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD04/09/2014§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WALL ERECTED FROM FLOOR TO CEILING USING SHEETROCK AND STUDS WITH DOOR CREATING ADDITIONAL ROOM IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1E, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT NORTH
Likely answered · the city's own records show a filing, but DOB's feed still lists these as active
DOB11/14/2025Violation issued-failure to file 2024 external low pressure inspectionAnswered on the city's records: a 2024 boiler inspection report was accepted (Feb 21, 2024)