← Back
Four families
2507 85 STREET
BROOKLYN · BIN 3185294
💬 Discuss this project
1923Year Built
2Stories
C3Building Class
R5Zoning
3,075 sfGross Floor Area
4Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Four families · 2,650 sf lot · 1.16 FAR built · Flood zone X500
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HT ASSOCIATES206/13/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HAOTIAN & ASSOCIATES INC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HT BUILDS LLCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FLUSHING ENGINEERING SERV4373106/01/2023
Building Lifecycle
All (22)Filed (2)Permit Issued (1)Signed Off (1)Violation (10)Inspection (1)Special Inspection (7)
06/06/2025
Violation issued (HPD, closed)
A
07/01/2024
Signed off — Alteration
PROPOSE EXTERIOR WORK ON THE FRONT FACADE, REPLACING BRICK ONLY. NO CHANGE IN USE, EGRESS, AND OCCUPANCY.
B00880559-I1
06/28/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/08/2024
Violation issued (HPD, closed)
A
06/22/2023
Permit issued — General Construction
B00880559-I1-GC
06/13/2023
Filed — Alteration
PROPOSE EXTERIOR WORK ON THE FRONT FACADE, REPLACING BRICK ONLY. NO CHANGE IN USE, EGRESS, AND OCCUPANCY.
B00880559-P1
06/13/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/13/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/13/2023
Special inspection requirement — Tenant Protection Plan Compliance
06/13/2023
Special inspection requirement — Energy Code Compliance Inspections
06/13/2023
Special inspection requirement — Fire-Resistance Rated Construction
06/13/2023
Special inspection requirement — Air barrier - visual inspection
06/13/2023
Special inspection requirement — Insulation placement and R values
06/01/2023
Filed — Alteration
PROPOSE EXTERIOR WORK ON THE FRONT FACADE, REPLACING BRICK ONLY. NO CHANGE IN USE, EGRESS, AND OCCUPANCY.
B00880559-I1
02/23/2022
Violation issued (HPD, closed)
A
03/11/2020
Violation issued (HPD, open)
C
03/11/2020
Violation issued (HPD, open)
A
11/17/2017
Violation issued (HPD, closed)
I
11/03/2016
Violation issued (HPD, closed)
I
10/07/2015
Violation issued (HPD, closed)
I
04/01/1998
Violation issued (ECB, closed)
Construction
07/25/1990
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offHT BUILDS LLC06/22/2023
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
06/28/2024Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
06/13/2023Fire-Resistant Penetrations and Joints—special
06/13/2023Structural Stability – Alterations of existing buildings—special
06/13/2023Tenant Protection Plan Compliance—special
06/13/2023Energy Code Compliance Inspections—progress
06/13/2023Fire-Resistance Rated Construction—progress
06/13/2023Air barrier - visual inspection—energy_progress
06/13/2023Insulation placement and R values—energy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026B00880559-P1Request digital key ↗
08/27/2026B00880559-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/27/2026B00880559-P1Open ↗
08/27/2026B00880559-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/27/2026B00880559-P1Open ↗
08/27/2026B00880559-I1Open ↗