← Back
Primarily 1 family with 1 store or office
251 WEST 13 STREET
MANHATTAN · West Village · BIN 1011131
💬 Discuss this project
1887Year Built
3Stories
S1Building Class
C1-6Zoning
7,735 sfGross Floor Area
2Units
5 Open Violations ▸
Primarily 1 family with 1 store or office · Owner of record: SL/TMF PRODUCTIONS INC. · 2,581 sf lot · 3 FAR built · Flood zone X
Locations of Work
Mechanical
Roof5p · 1 filing · 6 docs
Floor 34p · 1 filing · 6 docs
Floor 24p · 1 filing · 6 docs
Floor 14p · 1 filing · 6 docs
Site & exterior4p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
251 WEST 13 STREET COR203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
COLOMBO ARCHITECTURAL STUDIO PC106/16/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BREFFNI MECHANICAL INCGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
COLOMBO ARCHITECTURAL STU4930106/16/2021
Building Lifecycle
All (27)Filed (1)Permit Issued (1)Violation (23)Special Inspection (2)
07/07/2021
Permit issued — Mechanical Systems
M00526661-I1-MS
06/16/2021
Filed — Alteration
Direct replacement of (4) HVAC condensers and (3) Rooftop package units to connect to exisitng ductwork. No change in use, egress or occupancy.
M00526661-I1
05/21/2021
Special inspection requirement — Mechanical Systems
Yahaira Volquez Colombo
05/21/2021
Special inspection requirement — Final
Yahaira Volquez Colombo
10/01/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/24/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/01/2009
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/24/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/21/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/02/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/25/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/08/2001
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/10/2000
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/13/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/25/1999
Violation issued (DOB, open)
VPW-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE
01/20/1999
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/17/1995
Violation issued (ECB, closed)
Local Law
03/17/1995
Violation issued (ECB, closed)
Local Law
03/18/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedBREFFNI MECHANICAL07/07/2021
BISOTISSUEDMAK CONSTRUCION CORP11/23/1999
BISMHISSUEDMAK CONSTRUCION CORP11/23/1999
BISOTISSUEDMAK CONSTRUCION CORP11/23/1999
BISSPISSUEDKEW FOREST PLBG & HTG05/03/1999
BISPLISSUEDKEW FOREST PLBG & HTG INC12/17/1998
BISPLISSUEDKEW FOREST PLBG & HTG INC09/15/1998
BISOTISSUEDMAK CONSTRUCION CORP08/12/1998
BISMHISSUEDMAK CONSTRUCION CORP08/12/1998
BISOTISSUEDMAK CONSTRUCION CORP08/12/1998
BISOTISSUEDMAK CONSTRUCION CORP07/22/1998
BISMHISSUEDMAK CONSTRUCION CORP07/22/1998
BISOTISSUEDMAK CONSTRUCION CORP07/22/1998
BISPLISSUEDPERFECT PLUMBING & HEATING09/04/1997
BISOTRE-ISSUEDBRIGGS MECHANICAL ,INC.06/04/1997
1 project · most recent 06/16/2021
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/16/2021Permit IssuedBREFFNI MECHANICAL INCAir Conditioning Systems
Cooling
Trane 4TTL6048A1000 60,000 BTU · Condensing Unit ×2
TTA090043AAA 90,000 BTU · Condensing Unit ×1
WHC102H3RCA 102,000 BTU · Packaged Unit ×1
2 projects · most recent 01/05/2021
General Wiring
FiledStatusContractorScope
01/05/2021Permit IssuedPOWER FULL ELECTRIC, INCGeneral Wiring
02/07/2020Permit IssuedL.J.F. & SONS ELECL CONTS—
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
05/21/2021Mechanical SystemsYahaira Volquez Colombospecial
05/21/2021FinalYahaira Volquez Colomboprogress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
09/03/2026M00526661-I1Request digital key ↗
▸Applications & Permits1
▸DOB NOWLPC Approval/Permit1
08/13/2026M00526661-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026M00526661-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/24/2026M00526661-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026M00526661-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026M00526661-I1Open ↗