← Back
Miscellaneous one family
2514 TIEMANN AVENUE
BRONX · Pelham Gardens · BIN 2053492
💬 Discuss this project
1965Year Built
2Stories
A9Building Class
R4-1Zoning
1,944 sfGross Floor Area
1Units
Miscellaneous one family · 2,500 sf lot · 0.78 FAR built · Flood zone X
Locations of Work
Electrical
Roof1p · 1 filing · 17 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC209/05/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802209/05/2025
Building Lifecycle
All (14)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (10)
09/16/2025
Signed off — Alteration
X01248885-I1
09/11/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
09/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
09/11/2025
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
09/11/2025
Special inspection requirement — Final
Kaijin Liang
09/11/2025
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
09/05/2025
Filed — Alteration
X01248885-P1
09/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
09/05/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
09/05/2025
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
09/05/2025
Special inspection requirement — Final
Kaijin Liang
09/05/2025
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
07/09/2025
Permit issued — Solar
X01248885-I1-SL
06/30/2025
Filed — Alteration
X01248885-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP07/09/2025
2 projects · most recent 07/25/2025
FiledStatusContractorScope
07/25/2025CompleteBERGER QUALITY ELEC'L CON1 meters
06/26/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
09/11/2025Structural Stability – Alterations of existing buildingsKaijin Liangspecial
09/11/2025Fire-Resistant Penetrations and JointsKaijin Liangspecial
09/11/2025Energy Code Compliance InspectionsKaijin Liangprogress
09/11/2025FinalKaijin Liangprogress
09/11/2025Air barrier - visual inspectionKaijin Liangenergy_progress
09/05/2025Fire-Resistant Penetrations and JointsKaijin Liangspecial
09/05/2025Structural Stability – Alterations of existing buildingsKaijin Liangspecial
09/05/2025Energy Code Compliance InspectionsKaijin Liangprogress
09/05/2025FinalKaijin Liangprogress
09/05/2025Air barrier - visual inspectionKaijin Liangenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/19/2026X01248885-P1Request digital key ↗
08/19/2026X01248885-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
08/30/2026X01248885-I1Open ↗
08/30/2026X01248885-I1Open ↗
08/30/2026X01248885-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/30/2026X01248885-I1Open ↗
08/30/2026X01248885-I1Open ↗
08/22/2026X01248885-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/19/2026X01248885-P1Open ↗
08/19/2026X01248885-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/19/2026X01248885-P1Open ↗
08/19/2026X01248885-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01248885-I1Open ↗