← Back
Two family brick
253-28 WEST END DRIVE
QUEENS · Douglaston-Little Neck · BIN 4171603
💬 Discuss this project
1985Year Built
3Stories
B1Building Class
R3-1Zoning
3,600 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family brick · 5,285 sf lot · 0.68 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/03/2014$1.1M—Private party → Private party$292/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KYU LEE ARCHITECT, PC506/24/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HANKOOK HIC INCGeneral Contractor303/21/2026
BUILD RITE CONTRACTOR INCGeneral Contractor107/08/2026
CK PLUMBING & MECH INCPlumbing107/08/2026
Building Lifecycle
All (21)Filed (5)Permit Issued (3)Signed Off (3)Violation (4)Inspection (6)
08/26/2024
Signed off — Alteration
subsequent filing for plumbing work to comply ECB violations 39108605K; 39108604Z. No change in use, egress or occupancy under this application.
Q01029530-S1
08/07/2024
Signed off — Alteration
subsequent filing for plumbing work to comply ECB violations 39108605K; 39108604Z. No change in use, egress or occupancy under this application.
Q01029530-I1
06/24/2024
Filed — Alteration
subsequent filing for plumbing work to comply ECB violations 39108605K; 39108604Z. No change in use, egress or occupancy under this application.
Q01029530-P2
06/24/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/19/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/17/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/10/2024
Filed — Alteration
subsequent filing for plumbing work to comply ECB violations 39108605K; 39108604Z. No change in use, egress or occupancy under this application.
Q01029530-P1
05/30/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/22/2024
Permit issued — General Construction
Q01029530-I1-GC
05/22/2024
Permit issued — Plumbing
Q01029530-S1-PL
04/12/2024
Filed — Alteration
subsequent filing for plumbing work to comply ECB violations 39108605K; 39108604Z. No change in use, egress or occupancy under this application.
Q01029530-S1
04/12/2024
Filed — Alteration
subsequent filing for plumbing work to comply ECB violations 39108605K; 39108604Z. No change in use, egress or occupancy under this application.
Q01029530-I1
03/13/2024
Violation issued (ECB, closed)
Unknown
03/13/2024
Violation issued (ECB, closed)
Construction
06/21/2022
Signed off — Alteration
Q00724296-I1
06/17/2022
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
06/14/2022
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
05/25/2022
Permit issued — Curb Cut
Q00724296-I1-CC
04/27/2022
Filed — Alteration
Q00724296-I1
02/25/2022
Violation issued (ECB, closed)
Construction
02/25/2022
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offHANKOOK HIC INC05/22/2024
DOB NOWPlumbingSigned-offCK PLUMBING & MECH INC05/22/2024
DOB NOWCurb CutSigned-offBUILD RITE CONTRACTOR INC05/25/2022
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
06/24/2024Pass-Final General Construction Non-Directive 14PassView ↗
06/19/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/17/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/30/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/17/2022Pass-Final Curb Cut Non-Directive 14PassView ↗
06/14/2022Fail-Final Curb Cut Non-Directive 14FailView ↗
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/26/2026Q00724296-I1Request digital key ↗
08/22/2026Q01029530-P1Request digital key ↗
08/22/2026Q01029530-S1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/26/2026Q00724296-I1Open ↗
08/13/2026Q01029530-P2Open ↗
08/13/2026Q01029530-P1Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026Q01029530-P2Open ↗
08/13/2026Q01029530-I1Open ↗
08/13/2026Q01029530-P1Open ↗
Showing 3 of 4 on file for this type