← Back
Walk-up cooperative
251-02 61 AVENUE
QUEENS · BIN 4456236
💬 Discuss this project
1952Year Built
2Stories
C6Building Class
R3-2Zoning
189,016 sfGross Floor Area
216Units
LL97 CoveredRent Stabilized0 Open ViolationsFDNY Report ↗
Walk-up cooperative · Owner of record: DEEPDALE GARDENS THIRD CORP · 404,800 sf lot · 0.47 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DEEPDALE GARDENS907/08/2026
DEEPDALE GARDENS THIRD203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ROBERT GERMAIN JR. PE608/04/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BELL FUEL OIL, LLCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ROBERT F. GERMAIN JR. PE5100608/04/2021
Building Lifecycle
All (24)Filed (6)Permit Issued (5)Signed Off (2)Violation (2)Special Inspection (9)
10/14/2021
Signed off — Alteration
NEW GAS FIRED HOT WATER HEATER FOR SUMMER TIME USE ONLY. RECONNECT EXISTING LOW PRESSURE GAS LINE. NO CHANGE IN MEANS OF EGRESS USE GROUP OR OCCUPANCY.
Q00411357-I1
10/14/2021
Signed off — Alteration
REPLACEMENT (1) NEW LOW PRESSURE BOILER AND (1) NEW COMBINATION GAS/OIL BURNER. NO CHANGE IN MEANS OF EGRESS USE GROUP OR OCCUPANCY.
Q00411387-I1
08/17/2021
Permit issued — Boiler Equipment
Q00411387-I1-BE
08/05/2021
Special inspection requirement — Maintenance information
Robert Germain Jr.
08/05/2021
Special inspection requirement — HVAC and service water heating system controls
Robert Germain Jr.
08/05/2021
Special inspection requirement — HVAC and service water heating equipment
Robert Germain Jr.
08/05/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Germain Jr.
08/04/2021
Filed — Alteration
REPLACEMENT (1) NEW LOW PRESSURE BOILER AND (1) NEW COMBINATION GAS/OIL BURNER. NO CHANGE IN MEANS OF EGRESS USE GROUP OR OCCUPANCY.
Q00411387-P2
08/04/2021
Filed — Alteration
NEW GAS FIRED HOT WATER HEATER FOR SUMMER TIME USE ONLY. RECONNECT EXISTING LOW PRESSURE GAS LINE. NO CHANGE IN MEANS OF EGRESS USE GROUP OR OCCUPANCY.
Q00411357-P2
08/04/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Germain Jr.
08/04/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Germain Jr.
08/04/2021
Special inspection requirement — Maintenance information
Robert Germain Jr.
08/04/2021
Special inspection requirement — HVAC and service water heating equipment
Robert Germain Jr.
08/04/2021
Special inspection requirement — HVAC and service water heating system controls
Robert Germain Jr.
06/18/2021
Filed — Alteration
NEW GAS FIRED HOT WATER HEATER FOR SUMMER TIME USE ONLY. RECONNECT EXISTING LOW PRESSURE GAS LINE. NO CHANGE IN MEANS OF EGRESS USE GROUP OR OCCUPANCY.
Q00411357-P1
06/18/2021
Filed — Alteration
REPLACEMENT (1) NEW LOW PRESSURE BOILER AND (1) NEW COMBINATION GAS/OIL BURNER. NO CHANGE IN MEANS OF EGRESS USE GROUP OR OCCUPANCY.
Q00411387-P1
01/06/2021
Permit issued — Boiler Equipment
Q00411387-I1-BE
01/06/2021
Permit issued — Plumbing
Q00411357-I1-PL
12/07/2020
Permit issued — Boiler Equipment
Q00411387-I1-BE
12/04/2020
Filed — Alteration
REPLACEMENT (1) NEW LOW PRESSURE BOILER AND (1) NEW COMBINATION GAS/OIL BURNER. NO CHANGE IN MEANS OF EGRESS USE GROUP OR OCCUPANCY.
Q00411387-I1
12/03/2020
Filed — Alteration
NEW GAS FIRED HOT WATER HEATER FOR SUMMER TIME USE ONLY. RECONNECT EXISTING LOW PRESSURE GAS LINE. NO CHANGE IN MEANS OF EGRESS USE GROUP OR OCCUPANCY.
Q00411357-I1
12/03/2020
Permit issued — Plumbing
Q00411357-I1-PL
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/07/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentSigned-offABILENE, INC08/17/2021
DOB NOWBoiler EquipmentSigned-offABILENE, INC01/06/2021
DOB NOWPlumbingSigned-offBELL FUEL OIL, LLC01/06/2021
DOB NOWBoiler EquipmentSigned-offABILENE, INC12/07/2020
DOB NOWPlumbingSigned-offBELL FUEL OIL, LLC12/03/2020
BISOTISSUEDABILENE INC12/04/2020
BISOTISSUEDBRR RESTORATION CORP08/31/2015
BISPLISSUEDNAT'L MECH. SVCS PLBG LLC04/13/1995
BISOTISSUEDR.D. MORTMAN MECHANICAL04/04/1995
BISFBISSUEDWAYWOLFF ASSOC.INC.11/12/1993
BISPLISSUEDWARD MECHANICAL11/12/1993
BISPLISSUEDSIDERIS PLBG & HTG CORP10/30/1992
BISFBISSUEDSIDERIS PLBG & HTG CORP10/30/1992
1 project · most recent 05/13/2021
Boiler Controls
FiledStatusContractorScope
05/13/2021CompleteABILENE ELECTRIC INCBoiler Controls
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
08/05/2021Maintenance informationRobert Germain Jr.energy_progress
08/05/2021HVAC and service water heating system controls Robert Germain Jr.energy_progress
08/05/2021HVAC and service water heating equipment Robert Germain Jr.energy_progress
08/05/2021Fire-Resistant Penetrations and JointsRobert Germain Jr.special
08/04/2021Fire-Resistant Penetrations and JointsRobert Germain Jr.special
08/04/2021Fire-Resistant Penetrations and JointsRobert Germain Jr.special
08/04/2021Maintenance informationRobert Germain Jr.energy_progress
08/04/2021HVAC and service water heating equipment Robert Germain Jr.energy_progress
08/04/2021HVAC and service water heating system controls Robert Germain Jr.energy_progress
▾Documents — 61 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch - Plumbing3
08/27/2026Q00411357-I1Request digital key ↗
08/15/2026Q00411357-P2Request digital key ↗
08/15/2026Q00411357-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Boiler Equipment3
08/27/2026Q00411387-I1Request digital key ↗
08/15/2026Q00411387-P2Request digital key ↗
08/15/2026Q00411387-P1Request digital key ↗
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION4
12/01/2020440651992Open ↗
05/02/2016440246583Open ↗
03/22/2016440246583Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION2
12/04/2020440651992Open ↗
08/31/2015440246583Open ↗
▸Seals & Professional Certifications21
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/27/2026Q00411357-I1Open ↗
08/27/2026Q00411357-P1Open ↗
08/27/2026Q00411387-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026Q00411387-I1Open ↗
09/23/2026Q00411387-I1Open ↗
09/23/2026Q00411387-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026Q00411387-I1Open ↗
09/01/2026Q00411387-P2Open ↗
08/29/2026Q00411357-P2Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
12/01/2020440651992Open ↗
08/31/2015440246583Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
12/01/2020440651992Open ↗
08/31/2015440246583Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
12/01/2020440651992Open ↗
08/31/2015440246583Open ↗
▸Safety & Tenant Protection7
▸DOB NOWTenant Protection Plan6
08/27/2026Q00411357-I1Open ↗
08/27/2026Q00411357-P1Open ↗
08/13/2026Q00411387-P1Open ↗
Showing 3 of 6 on file for this type
▸BISTPP1: TENANT PROTECTION PLAN1
12/04/2020440651992Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/27/2026Q00411357-P1Open ↗
08/27/2026Q00411357-I1Open ↗
08/27/2026Q00411387-P2Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/01/2020440651992Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
12/01/2020440651992Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
10/19/2021440651992Open ↗
▸BISNYCECC ANALYSIS1
12/01/2020440651992Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q00411387-I1Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY4
10/19/2021440651992Open ↗
12/04/2020440651992Open ↗
12/01/2020440651992Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/19/2021440651992Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
10/19/2021440651992Open ↗
12/01/2020440651992Open ↗
08/31/2015440246583Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET2
12/01/2020440651992Open ↗
08/31/2015440246583Open ↗