← Back
Miscellaneous two family
253 HOYT STREET
BROOKLYN · BIN 3006762
💬 Discuss this project
1901Year Built
2Stories
B9Building Class
R6BZoning
2,400 sfGross Floor Area
2Units
Miscellaneous two family · 1,600 sf lot · 1.5 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 3Under Construction23p · 1 filing · 20 docs
Floor 2Under Construction23p · 1 filing · 20 docs
Floor 1Under Construction23p · 1 filing · 20 docs
CellarUnder Construction22p · 1 filing · 20 docs
Sub-BasementUnder Construction4p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/14/2021$2.9M—Private party → Private party$1,188/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HANSEN ENGINEERING, PC311/12/2025
STUDIO NYANDAK ARCHITECTURE AND ENG104/14/2025
NOROOF ARCHITECTS103/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GREEN LIGHT EXPEDITING LLC1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRO RENO NYC CORPGeneral Contractor307/08/2026
ARIANA CONTRACTING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HANSEN ENGINEERING PC8174311/12/2025
STUDIO NYANDAK ARCHITECTU8378104/14/2025
NOROOF ARCHITECTS1694103/21/2025
Building Lifecycle
All (53)Filed (5)Permit Issued (4)Inspection (5)Objection (12)Special Inspection (27)
04/17/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/16/2026
Permit issued — General Construction
B01183250-I1-GC
01/29/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
01/27/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/20/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/17/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ryan Hansen
11/14/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Ryan Hansen
11/12/2025
Filed — Alteration
Filing to install mini-split HVAC System for cooling and heating as per plans. No change in use, egress, or occupancy under this application.
B01183250-P1
10/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ryan Hansen
10/29/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Ryan Hansen
07/11/2025
Permit issued — Plumbing
B01183250-S2-PL
06/10/2025
Permit issued — Structural
B01183250-S1-ST
06/05/2025
Objection resolved — Addressed
05/20/2025
Objection raised — Cost
05/19/2025
Filed — Alteration
Filing to install mini-split HVAC System for cooling and heating as per plans. No change in use, egress, or occupancy under this application.
B01183250-S3
05/19/2025
Filed — Alteration
Filing to install mini-split HVAC System for cooling and heating as per plans. No change in use, egress, or occupancy under this application.
B01183250-S2
05/19/2025
Special inspection requirement — Duct leakage testing, insulation and design
Ryan Hansen
04/24/2025
Permit issued — General Construction
B01183250-I1-GC
04/24/2025
Objection resolved — Addressed
04/24/2025
Objection resolved — Addressed
04/24/2025
Objection resolved — Addressed
04/24/2025
Objection resolved — Addressed
04/23/2025
Objection raised — Scope
04/23/2025
Objection raised — Cost
04/23/2025
Objection raised — Structural
04/23/2025
Objection raised — Structural
04/21/2025
Special inspection requirement — HVAC-R and service water heating equipment
Ryan Hansen
04/21/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Ryan Hansen
04/21/2025
Special inspection requirement — Permanent certificate
Ryan Hansen
04/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ryan Hansen
04/21/2025
Special inspection requirement — Energy Code Compliance Inspections
Ryan Hansen
04/21/2025
Special inspection requirement — HVAC-R and service water heating system controls
Ryan Hansen
04/21/2025
Special inspection requirement — Maintenance information
Ryan Hansen
04/14/2025
Filed — Alteration
Filing to install mini-split HVAC System for cooling and heating as per plans. No change in use, egress, or occupancy under this application.
B01183250-S1
04/11/2025
Objection resolved — Addressed
03/27/2025
Objection raised — Cost
03/21/2025
Filed — Alteration
Filing to install mini-split HVAC System for cooling and heating as per plans. No change in use, egress, or occupancy under this application.
B01183250-I1
03/04/2025
Special inspection requirement — Energy Code Compliance Inspections
WILLIAM OLIVER
03/04/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
WILLIAM OLIVER
03/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM OLIVER
03/04/2025
Special inspection requirement — Air barrier - visual inspection
WILLIAM OLIVER
03/04/2025
Special inspection requirement — Fenestration air leakage
WILLIAM OLIVER
03/04/2025
Special inspection requirement — Insulation placement and R values
WILLIAM OLIVER
03/04/2025
Special inspection requirement — Fenestration areas
WILLIAM OLIVER
03/04/2025
Special inspection requirement — Maintenance information
WILLIAM OLIVER
03/04/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
WILLIAM OLIVER
03/04/2025
Special inspection requirement — Metering
WILLIAM OLIVER
03/04/2025
Special inspection requirement — Permanent certificate
WILLIAM OLIVER
03/04/2025
Special inspection requirement — Lighting in dwelling units
WILLIAM OLIVER
02/26/2025
Special inspection requirement — Mechanical Systems
Ryan Hansen
02/26/2025
Special inspection requirement — Final
Ryan Hansen
02/19/2025
Special inspection requirement — Final
WILLIAM OLIVER
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedPRO RENO NYC CORP04/16/2026
DOB NOWPlumbingSigned-offARIANA CONTRACTING INC07/11/2025
DOB NOWStructuralPermit IssuedPRO RENO NYC CORP06/10/2025
DOB NOWGeneral ConstructionPermit IssuedPRO RENO NYC CORP04/24/2025
BISPLISSUEDRKA PIPING AND HEATING02/16/2024
BISPLISSUEDRKA PIPING AND HEATING01/19/2023
BISOTISSUEDCARLOS PADILLO DBA THE HA04/01/2014
BISOTISSUEDCITY SUBURB INC06/28/2013
BISOTISSUEDCARLOS PADILLO DBA THE HA06/06/2013
1 project · most recent 11/12/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
11/12/2025Permit IssuedPRO RENO NYC CORPHeating and Air Conditioning Systems
Heat / Cool
Samsung AM007TNVDCH/AA 7,500 BTU · Vrf Indoor ×1
AM009TNVDCH/AA 9,500 BTU · Vrf Indoor ×1
AM018ANMDCH/AA 18,000 BTU · Vrf Indoor ×1
AM018TNZDCH/AA 18,000 BTU · Vrf Indoor ×1
AM048NXMDCR/AA 48,000 BTU · Vrf Outdoor ×1
1 project · most recent 11/12/2025
Gas Water/Sanitary
FiledStatusContractorScope
11/12/2025Signed-offARIANA CONTRACTING INCGas, Water/Sanitary
2 projects · most recent 05/06/2025
General Wiring
FiledStatusContractorScope
05/06/2025CompleteCL ELECTRICAL CORPGeneral Wiring
04/20/2023Permit IssuedR.A. PHILLIPS ELEC'L CONT3 meters, 1 new_meters
1 project · most recent 11/12/2025
Steel
FiledStatusContractorScope
11/12/2025Permit IssuedPRO RENO NYC CORPSteel
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/17/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/29/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/27/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/20/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/17/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 27
DateRequirementInspectorRole
11/14/2025Fire-Resistant Penetrations and JointsRyan Hansenspecial
11/14/2025HVAC-R and service water piping design and insulationRyan Hansenenergy_progress
10/29/2025Fire-Resistant Penetrations and JointsRyan Hansenspecial
10/29/2025HVAC-R and service water piping design and insulationRyan Hansenenergy_progress
05/19/2025Duct leakage testing, insulation and designRyan Hansenenergy_progress
04/21/2025HVAC-R and service water heating equipmentRyan Hansenenergy_progress
04/21/2025HVAC-R and service water piping design and insulationRyan Hansenenergy_progress
04/21/2025Permanent certificateRyan Hansenenergy_progress
04/21/2025Fire-Resistant Penetrations and JointsRyan Hansenspecial
04/21/2025Energy Code Compliance InspectionsRyan Hansenprogress
04/21/2025HVAC-R and service water heating system controlsRyan Hansenenergy_progress
04/21/2025Maintenance informationRyan Hansenenergy_progress
03/04/2025Energy Code Compliance InspectionsWILLIAM OLIVERprogress
03/04/2025Exterior Insulation and Finish Systems (EIFS)WILLIAM OLIVERspecial
03/04/2025Fire-Resistant Penetrations and JointsWILLIAM OLIVERspecial
03/04/2025Air barrier - visual inspectionWILLIAM OLIVERenergy_progress
03/04/2025Fenestration air leakageWILLIAM OLIVERenergy_progress
03/04/2025Insulation placement and R valuesWILLIAM OLIVERenergy_progress
03/04/2025Fenestration areasWILLIAM OLIVERenergy_progress
03/04/2025Maintenance informationWILLIAM OLIVERenergy_progress
03/04/2025Fenestration and door U-factor and product ratingsWILLIAM OLIVERenergy_progress
03/04/2025MeteringWILLIAM OLIVERenergy_progress
03/04/2025Permanent certificateWILLIAM OLIVERenergy_progress
03/04/2025Lighting in dwelling unitsWILLIAM OLIVERenergy_progress
02/26/2025Mechanical SystemsRyan Hansenspecial
Latest 25 of 27.
▾Documents — 93 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/21/2026B01183250-S2Request digital key ↗
08/21/2026B01183250-S1Request digital key ↗
08/21/2026B01183250-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits13
▸BISPLAN / WORK APPROVAL APPLICATION9
07/23/2024320728174Open ↗
04/03/2024320728174Open ↗
11/20/2023320728174Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION4
01/19/2023320728174Open ↗
07/07/2014320728174Open ↗
06/27/2013340071059Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications33
▸DOB NOWProgress Inspector Seal & Signature14
09/01/2026B01183250-S2Open ↗
08/31/2026B01183250-I1Open ↗
08/31/2026B01183250-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/01/2026B01183250-S2Open ↗
08/31/2026B01183250-I1Open ↗
08/31/2026B01183250-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
12/18/2018321760894Open ↗
07/18/2018321760894Open ↗
07/03/2018321760894Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/21/2026B01183250-S2Open ↗
08/13/2026B01183250-I1Open ↗
08/13/2026B01183250-P1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/27/2013340071059Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
06/27/2013340071059Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
06/27/2013340071059Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE B - PLUMBING4
04/03/2024320728174Open ↗
11/20/2023320728174Open ↗
08/16/2023320728174Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
07/03/2018321760894Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
03/26/2013320728174Open ↗
▸BISTenant Protection Plan and Notes1
07/18/2018321760894Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/21/2026B01183250-S2Open ↗
08/13/2026B01183250-I1Open ↗
08/13/2026B01183250-S1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
12/18/2018321760894Open ↗
07/03/2018321760894Open ↗
06/27/2013340071059Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
07/03/2018321760894Open ↗
03/26/2013320728174Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
06/27/2013340071059Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
12/21/2023320728174Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
09/10/2024320728174Open ↗
▸Inspections & Test Reports6
▸BISTECHNICAL REPORT: RESPONSIBILITY3
12/21/2023320728174Open ↗
12/21/2023320728174Open ↗
06/27/2013340071059Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
09/10/2024320728174Open ↗
▸BISMECHANICAL SYSTEMS1
09/10/2024320728174Open ↗
▸BISSOIL REPORT1
12/18/2018321760894Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
09/11/2024320728174Open ↗
▸BISFINAL1
09/10/2024320728174Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
03/26/2013320728174Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT4
12/18/2018321760894Open ↗
07/03/2018321760894Open ↗
06/27/2013340071059Open ↗
Showing 3 of 4 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW32
09/10/2024320728174Open ↗
09/10/2024320728174Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION3
07/30/2024320728174Open ↗
04/12/2024320728174Open ↗
12/29/2023320728174Open ↗
▸BISEFILING COVER SHEET2
07/03/2018321760894Open ↗
03/26/2013320728174Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
06/27/2013340071059Open ↗