← Back
Two stories - detached, small or mid-size
2532 POPLAR STREET
BRONX · Morris Park · BIN 2044142
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R4Zoning
1,300 sfGross Floor Area
1Units
2 Open Violations 1 unresolved · 1 paperwork only ▸
Two stories - detached, small or mid-size · 2,908 sf lot · 0.45 FAR built · Flood zone X
Locations of Work
Structural
Permit Issued — active, not yet Signed-off
Floor 2Under Construction1p · 1 filing · 14 docs
Floor 1Under Construction1p · 1 filing · 14 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/31/2019$510K—— → —$392/sf building
03/04/2019$285K—— → —$219/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SAFIYA CONSULTANTS INC207/15/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EJ HOMES 45 LLCGeneral Contractor104/09/2026
ARCO PLBG AND HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WORLD DESIGN ARCHITECTURE9323207/15/2025
Building Lifecycle
All (33)Filed (2)Permit Issued (2)Violation (4)Inspection (12)Special Inspection (13)
05/14/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/27/2026
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
04/23/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/27/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/26/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/20/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/18/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/13/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/04/2026
Permit issued — Plumbing
X01141422-S1-PL
12/09/2025
Permit issued — Structural
X01141422-I1-GC-CX
11/24/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/15/2025
Filed — Alteration
INSTLL DRY WELL AND ONE BATHROOM AS PER PLAN, TO FOLLOW ALT-2
X01141422-S1
06/25/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Alicea
06/25/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
William Alicea
12/24/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/24/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/24/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/04/2024
Filed — Alteration
INSTLL DRY WELL AND ONE BATHROOM AS PER PLAN, TO FOLLOW ALT-2
X01141422-I1
11/12/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Alicea
11/12/2024
Special inspection requirement — Final
William Alicea
11/12/2024
Special inspection requirement — Energy Code Compliance Inspections
William Alicea
11/12/2024
Special inspection requirement — Fire-Resistance Rated Construction
William Alicea
11/12/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
William Alicea
11/12/2024
Special inspection requirement — Insulation placement and R values
William Alicea
11/12/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
William Alicea
11/12/2024
Special inspection requirement — Air barrier - visual inspection
William Alicea
11/12/2024
Special inspection requirement — Interior lighting power
William Alicea
11/12/2024
Special inspection requirement — Structural Wood Frame
William Alicea
11/12/2024
Special inspection requirement — Concrete - Cast-In-Place
William Alicea
05/26/2021
Violation issued (ECB, closed)
Construction
05/26/2021
Violation issued (ECB, closed)
Construction
05/26/2021
Violation issued (ECB, open)
Zoning
06/02/2020
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offARCO PLBG AND HTG INC03/04/2026
DOB NOWStructuralPermit IssuedEJ HOMES 4512/09/2025
1 project · most recent 07/15/2025
Water/Sanitary
FiledStatusContractorScope
07/15/2025Signed-offARCO PLBG AND HTG INCWater/Sanitary
1 project · most recent 03/26/2026
General Wiring
FiledStatusContractorScope
03/26/2026Permit IssuedJOSEPH WEINSTEIN ELECTRICGeneral Wiring
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
05/14/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/27/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
04/23/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/27/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/26/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/20/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
03/18/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/13/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/24/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/24/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/24/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/24/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
06/25/2025Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
06/25/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationWilliam Aliceaspecial
11/12/2024Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
11/12/2024FinalWilliam Aliceaprogress
11/12/2024Energy Code Compliance InspectionsWilliam Aliceaprogress
11/12/2024Fire-Resistance Rated ConstructionWilliam Aliceaprogress
11/12/2024Structural Stability – Alterations of existing buildingsWilliam Aliceaspecial
11/12/2024Insulation placement and R valuesWilliam Aliceaenergy_progress
11/12/2024Fenestration and door U-factor and product ratingsWilliam Aliceaenergy_progress
11/12/2024Air barrier - visual inspectionWilliam Aliceaenergy_progress
11/12/2024Interior lighting powerWilliam Aliceaenergy_progress
11/12/2024Structural Wood FrameWilliam Aliceaprogress
11/12/2024Concrete - Cast-In-PlaceWilliam Aliceaspecial
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026X01141422-S1Request digital key ↗
08/20/2026X01141422-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026X01141422-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026X01141422-I1Open ↗
08/24/2026X01141422-S1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026X01141422-I1Open ↗
08/20/2026X01141422-S1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026X01141422-I1Open ↗
09/01/2026X01141422-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026X01141422-S1Open ↗
08/20/2026X01141422-I1Open ↗
▸Other Documents3
▸DOB NOWSite Survey: Initial1
08/13/2026X01141422-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026X01141422-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026X01141422-I1Open ↗