← Back
One family attached or semi-detached
2534 MATTHEWS AVENUE
BRONX · Allerton · BIN 2051541
💬 Discuss this project
1955Year Built
2Stories
A5Building Class
R6Zoning
1,998 sfGross Floor Area
1Units
One family attached or semi-detached · 2,300 sf lot · 0.87 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
Floor 2Under Construction3p · 1 filing · 10 docs
Floor 1Under Construction3p · 1 filing · 10 docs
BasementUnder Construction3p · 1 filing · 10 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/31/2023$500K—Private party → Private party$250/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MICHAEL SCADUTO ARCHITECT108/15/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GIOVANNI MARTINI CONTRACTGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MICHAEL SCADUTO ARCHITECT4833108/15/2023
Building Lifecycle
All (30)Filed (1)Permit Issued (1)Inspection (8)Objection (14)Special Inspection (6)
04/27/2026
Inspection — Fail-Final Construction Permit Withdrawal
Fail
View inspection ↗
04/15/2026
Inspection — Fail-Final Construction Permit Withdrawal
Fail
View inspection ↗
05/10/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/26/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
04/04/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
03/25/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
02/06/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
12/26/2023
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
11/30/2023
Permit issued — General Construction
X00903028-I1-GC
11/22/2023
Objection resolved — Addressed
11/21/2023
Objection raised — Other
11/15/2023
Objection resolved — Addressed
11/15/2023
Objection resolved — Addressed
11/15/2023
Special inspection requirement — Energy Code Compliance Inspections
Michael Scaduto
11/15/2023
Special inspection requirement — Interior lighting power
Michael Scaduto
11/15/2023
Special inspection requirement — Metering
Michael Scaduto
11/06/2023
Objection resolved — Addressed
11/06/2023
Objection resolved — Addressed
11/06/2023
Objection resolved — Addressed
08/23/2023
Objection raised — Other
08/23/2023
Objection resolved — Addressed
08/22/2023
Objection raised — Zoning
08/22/2023
Objection raised — Other
08/22/2023
Objection raised — Other
08/22/2023
Objection raised — Scope
08/22/2023
Objection raised — Zoning
08/15/2023
Filed — Alteration CO
minor interior renovation of basement & conversion to residential use. Change from 1-fam to 2-fam. No changes to egress.
X00903028-I1
08/15/2023
Special inspection requirement — Tenant Protection Plan Compliance
Michael Scaduto
07/12/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Michael Scaduto
07/12/2023
Special inspection requirement — Fire-Resistance Rated Construction
Michael Scaduto
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedBARTOSZ WINSKO11/30/2023
1 project · most recent 05/08/2024
General Wiring
FiledStatusContractorScope
05/08/2024CompleteEMPIRE LIC ELECL CONTRSGeneral Wiring
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
04/27/2026Fail-Final Construction Permit WithdrawalFailView ↗
04/15/2026Fail-Final Construction Permit WithdrawalFailView ↗
05/10/2024Pass-Final CND-Occupancy InspectionPassView ↗
04/26/2024Pass-Final PL - UndergroundPassView ↗
04/04/2024Pass-Final PL - UndergroundPassView ↗
03/25/2024Pass-Final PL - UndergroundPassView ↗
02/06/2024Pass-Final PL - UndergroundPassView ↗
12/26/2023Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
11/15/2023Energy Code Compliance InspectionsMichael Scadutoprogress
11/15/2023Interior lighting powerMichael Scadutoenergy_progress
11/15/2023MeteringMichael Scadutoenergy_progress
08/15/2023Tenant Protection Plan ComplianceMichael Scadutospecial
07/12/2023Fire-Resistant Penetrations and JointsMichael Scadutospecial
07/12/2023Fire-Resistance Rated ConstructionMichael Scadutoprogress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026X00903028-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature4
09/02/2026X00903028-I1Open ↗
09/02/2026X00903028-I1Open ↗
09/02/2026X00903028-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/02/2026X00903028-I1Open ↗
09/02/2026X00903028-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/22/2026X00903028-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026X00903028-I1Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/22/2026X00903028-I1Open ↗