← Back
Five to six families
254 MELROSE STREET
BROOKLYN · Bushwick (West) · BIN 3072064
💬 Discuss this project
1931Year Built
3Stories
C2Building Class
R6Zoning
5,355 sfGross Floor Area
6Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Five to six families · Owner of record: 254 MELROSE LLC · 2,625 sf lot · 2.04 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction25p · 1 filing · 20 docs
PenthouseUnder Construction25p · 1 filing · 20 docs
Floor 4Under Construction24p · 2 filings · 20 docs
Floor 3Under Construction30p · 1 filing · 20 docs
Floor 2Under Construction26p · 2 filings · 20 docs
Floor 1Under Construction24p · 1 filing · 20 docs
CellarUnder Construction29p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
254 MELROSE2207/08/2026
JAKE NATE CONSTRUCTION1107/08/2026
PRECISION OWNERS1204/09/2026
PRECISION BUILDERS USA103/22/2026
SSH REALTY MANAGEMENT203/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEVM EXPEDITORS2003/21/2026
JYA EXPEDITERS GROUP.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JAKE AND NATE CONSTRUCTGeneral Contractor407/08/2026
PRECISION BUILDERS USAGeneral Contractor407/08/2026
PRECISION BUILD USA INCGeneral Contractor207/08/2026
DYNAMIC PLBNG & SPRKR CORFire Protection107/08/2026
MW CONSTRUCTION INCGeneral Contractor107/08/2026
DYNAMIC PLBG & SPRKLR CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE20501106/26/2024
AUTOMATED DESIGN CONSULTA8952—
Building Lifecycle
All (149)Filed (15)Permit Issued (13)Signed Off (6)Violation (58)Inspection (13)Objection (14)Special Inspection (30)
07/17/2026
Violation issued (HPD, closed)
A
07/17/2026
Violation issued (HPD, closed)
A
07/17/2026
Violation issued (HPD, closed)
A
07/17/2026
Violation issued (HPD, closed)
B
07/17/2026
Violation issued (HPD, closed)
A
07/17/2026
Violation issued (HPD, closed)
A
07/17/2026
Violation issued (HPD, closed)
A
07/03/2026
Violation issued (HPD, closed)
C
10/28/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/26/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/07/2024
Signed off — Alteration
Install mechanical systems in conjunction with Alt-CO #B00655671-I1. There is no change in use, occupancy or egress.
B00876318-I1
07/31/2024
Signed off — Alteration CO
STRUCTURAL/ FOUNDATION/ UNDERPINNING/ WORK TYPES FILED IN CONJUNCTION WITH ALTERATION CO JOB NUMBER:B00655671-I1, FOUR (4) STORY BUILDING WITH PENTHOUSE, AND TOTAL OF NINE (9) CLASS A APARTMENTS,
B00655671-S1
06/27/2024
Special inspection requirement — Shutoff dampers
PAUL MARINO
06/27/2024
Special inspection requirement — Maintenance information
PAUL MARINO
06/27/2024
Special inspection requirement — HVAC-R and service water heating equipment
PAUL MARINO
06/27/2024
Special inspection requirement — Ventilation and air distribution system
PAUL MARINO
06/27/2024
Special inspection requirement — HVAC-R and service water heating system controls
PAUL MARINO
06/27/2024
Special inspection requirement — Final
Shahrish Shuvo
06/27/2024
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
06/27/2024
Special inspection requirement — Mechanical Systems
PAUL MARINO
06/27/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
06/26/2024
Filed — Alteration
Install mechanical systems in conjunction with Alt-CO #B00655671-I1. There is no change in use, occupancy or egress.
B00876318-P1
05/03/2024
Signed off — Alteration
Install plumbing and sprinkler systems in conjunction with Alt-CO #B00655671. There is no change in use occupancy or egress.
B00876272-I1
04/11/2024
Violation issued (HPD, closed)
A
03/13/2024
Filed — Alteration
Install plumbing and sprinkler systems in conjunction with Alt-CO #B00655671. There is no change in use occupancy or egress.
B00876272-P2
03/13/2024
Special inspection requirement — Sprinkler Systems
PAUL MARINO
03/13/2024
Special inspection requirement — Maintenance information
PAUL MARINO
03/13/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
03/13/2024
Special inspection requirement — HVAC-R and service water heating system controls
PAUL MARINO
03/13/2024
Special inspection requirement — HVAC-R and service water heating equipment
PAUL MARINO
03/13/2024
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
03/07/2024
Special inspection requirement — Shutoff dampers
PAUL MARINO
03/07/2024
Special inspection requirement — Ventilation and air distribution system
PAUL MARINO
03/07/2024
Special inspection requirement — HVAC-R and service water heating equipment
PAUL MARINO
03/07/2024
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
03/07/2024
Special inspection requirement — Final
Gregory Mortman
03/07/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
03/07/2024
Special inspection requirement — HVAC-R and service water heating system controls
PAUL MARINO
03/07/2024
Special inspection requirement — Mechanical Systems
PAUL MARINO
03/07/2024
Special inspection requirement — Maintenance information
PAUL MARINO
02/29/2024
Signed off — Alteration
Renovation to the interior of an existing 3 story building, which includes but is not limited to wall finishes, floor finishes, kitchen appliances, no change in occupancy, construction classification, egress, or zoning,
B00647602-I1
02/20/2024
Filed — Alteration CO
STRUCTURAL/ FOUNDATION/ UNDERPINNING/ WORK TYPES FILED IN CONJUNCTION WITH ALTERATION CO JOB NUMBER:B00655671-I1, FOUR (4) STORY BUILDING WITH PENTHOUSE, AND TOTAL OF NINE (9) CLASS A APARTMENTS,
B00655671-P4
02/15/2024
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
02/15/2024
Special inspection requirement — Sprinkler Systems
PAUL MARINO
02/15/2024
Special inspection requirement — HVAC-R and service water heating system controls
PAUL MARINO
02/15/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
02/15/2024
Special inspection requirement — Maintenance information
PAUL MARINO
02/15/2024
Special inspection requirement — HVAC-R and service water heating equipment
PAUL MARINO
02/07/2024
Filed — Alteration
Install plumbing and sprinkler systems in conjunction with Alt-CO #B00655671. There is no change in use occupancy or egress.
B00876272-P1
01/17/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/20/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/13/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/29/2023
Inspection — Pass-Final SP - Up to 3 Requested Floors
Pass
View inspection ↗
11/15/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
11/15/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
11/15/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/15/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/21/2023
Inspection — No Access-Final SP - Up to 3 Requested Floors
No Access
View inspection ↗
09/18/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
09/15/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
Latest 60 of 149 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offCITYWIDE PLBG, HTG &SPRKL09/07/2023
DOB NOWMechanical SystemsSigned-offPRECISION BUILD USA INC09/07/2023
DOB NOWPlumbingSigned-offCITYWIDE PLBG HTG & SPKLS09/07/2023
DOB NOWGeneral ConstructionPermit IssuedPRECISION BUILD USA INC05/12/2023
DOB NOWGeneral ConstructionPermit IssuedMW CONSTRUCTION INC03/24/2023
DOB NOWSidewalk ShedSigned-offJAKE AND NATE CONSTRUCT03/14/2023
DOB NOWSupported ScaffoldSigned-offJAKE AND NATE CONSTRUCT03/08/2023
DOB NOWGeneral ConstructionSigned-offPRECISION BUILDERS USA02/22/2023
DOB NOWFoundationSigned-offPRECISION BUILDERS USA02/09/2023
DOB NOWSidewalk ShedSigned-offJAKE AND NATE CONSTRUCT01/18/2023
DOB NOWSupported ScaffoldSigned-offJAKE AND NATE CONSTRUCT01/18/2023
DOB NOWGeneral ConstructionPermit IssuedPRECISION BUILDERS USA12/28/2022
DOB NOWGeneral ConstructionSigned-offPRECISION BUILDERS USA01/14/2022
1 project
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
———Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Fujitsu ASU7RLF1 7,000 BTU · Ahu ×23
AOU36RLXFZH 35,200 BTU · Heat Pump Outdoor ×9
ASU12RLF1 12,000 BTU · Ahu ×9
AOUG09LZAS1 9,000 BTU · Heat Pump Outdoor ×1
AOUG12LZAH1 12,000 BTU · Heat Pump Outdoor ×1
ASUG09LZAS1 9,000 BTU · Ahu ×1
ASUG12LZAH1 12,000 BTU · Ahu ×1
Cadet CEC163TW 5,115 BTU · Electric Heater ×9
Ventilation
Broan BHFLED110 75 CFM · Exhaust Fan ×18
433011 150 CFM · Kitchen Exhaust ×8
Fantech REC6 with speed control 160 CFM · Exhaust Fan ×2
1 project
FiledStatusContractorScope
———77 heads
1 project
Storm Water/Sanitary
FiledStatusContractorScope
———Storm, Water/Sanitary
4 projects · most recent 05/09/2023
General Wiring
FiledStatusContractorScope
05/09/2023CompleteTFK ELECTRIC CORP10 meters, 10 new_meters
02/01/2023CompleteTFK ELECTRIC CORPGeneral Wiring
01/20/2023CompleteRICHARD NEU—
02/10/2022CompleteTFK ELECTRIC CORP—
1 project · most recent 02/20/2024
Masonry
FiledStatusContractorScope
02/20/2024Permit IssuedPRECISION BUILD USA INCMasonry
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
10/28/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/26/2024Pass-Final CND-Occupancy InspectionPassView ↗
01/17/2024Pass-Final General Construction Non-Directive 14PassView ↗
12/20/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/13/2023Pass-Final CND-Occupancy InspectionPassView ↗
11/29/2023Pass-Final SP - Up to 3 Requested FloorsPassView ↗
11/15/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
11/15/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
11/15/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/15/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
09/21/2023No Access-Final SP - Up to 3 Requested FloorsNo AccessView ↗
09/18/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/15/2023Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 86
DateRequirementInspectorRole
06/27/2024Mechanical SystemsPAUL MARINOspecial
06/27/2024HVAC-R and service water heating system controlsPAUL MARINOenergy_progress
06/27/2024HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
06/27/2024Maintenance informationPAUL MARINOenergy_progress
06/27/2024HVAC-R and service water heating equipmentPAUL MARINOenergy_progress
06/27/2024Shutoff dampersPAUL MARINOenergy_progress
06/27/2024Ventilation and air distribution systemPAUL MARINOenergy_progress
06/27/2024FinalShahrish Shuvoprogress
06/27/2024Energy Code Compliance InspectionsPAUL MARINOprogress
03/13/2024Energy Code Compliance InspectionsPAUL MARINOprogress
03/13/2024Maintenance informationPAUL MARINOenergy_progress
03/13/2024HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
03/13/2024HVAC-R and service water heating system controlsPAUL MARINOenergy_progress
03/13/2024Sprinkler SystemsPAUL MARINOspecial
03/13/2024HVAC-R and service water heating equipmentPAUL MARINOenergy_progress
03/07/2024Maintenance informationPAUL MARINOenergy_progress
03/07/2024Mechanical SystemsPAUL MARINOspecial
03/07/2024Energy Code Compliance InspectionsPAUL MARINOprogress
03/07/2024FinalGregory Mortmanprogress
03/07/2024HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
03/07/2024HVAC-R and service water heating system controlsPAUL MARINOenergy_progress
03/07/2024Shutoff dampersPAUL MARINOenergy_progress
03/07/2024Ventilation and air distribution systemPAUL MARINOenergy_progress
03/07/2024HVAC-R and service water heating equipmentPAUL MARINOenergy_progress
02/15/2024HVAC-R and service water heating system controlsPAUL MARINOenergy_progress
Latest 25 of 86.
▾Documents — 161 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch17
09/03/2026B00735402-I1Request digital key ↗
09/03/2026B08039108-I1Request digital key ↗
08/31/2026B00647602-I1Request digital key ↗
Showing 3 of 17 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION4
02/15/2024321730748Open ↗
12/30/2020321730748Open ↗
09/03/2020321730748Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
01/25/2021321730748Open ↗
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026B00655671-P4Open ↗
08/13/2026B00655671-P1Open ↗
08/13/2026B00655671-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)3
08/13/2026B00655671-P4Open ↗
08/13/2026B00655671-I1Open ↗
08/13/2026B00655671-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00655671-I1Open ↗
▸Seals & Professional Certifications73
▸DOB NOWProgress Inspector Seal & Signature29
09/23/2026B00876272-I1Open ↗
09/23/2026B00876272-I1Open ↗
09/13/2026B00876318-I1Open ↗
Showing 3 of 29 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature26
09/23/2026B00876272-I1Open ↗
09/13/2026B00876318-I1Open ↗
09/01/2026B00876272-P2Open ↗
Showing 3 of 26 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature17
09/03/2026B00735402-I1Open ↗
09/03/2026B08039108-I1Open ↗
08/31/2026B00647602-I1Open ↗
Showing 3 of 17 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
04/27/2018321730748Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
04/27/2018321730748Open ↗
▸Safety & Tenant Protection13
▸DOB NOWStreet Tree Checklist6
08/13/2026B00655671-P2Open ↗
08/13/2026B00655671-I1Open ↗
08/13/2026B00655671-P4Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWStreet Tree Sign Off2
08/13/2026B00655671-S1Open ↗
08/13/2026B00655671-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan2
08/13/2026B00655671-I1Open ↗
08/13/2026B00655671-S1Open ↗
▸BISTenant Protection Plan and Notes1
04/27/2018321730748Open ↗
▸BISSTREET TREE CHECKLIST1
04/27/2018321730748Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00655671-I1Open ↗
▸Environmental & Asbestos14
▸DOB NOWDEP ACP-5: Asbestos Assessment Report13
09/03/2026B08039108-I1Open ↗
08/31/2026B00647602-I1Open ↗
08/28/2026B00655671-P4Open ↗
Showing 3 of 13 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/27/2018321730748Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
04/27/2018321730748Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00655671-I1Open ↗
▸Approvals, Objections & Sign-offs4
▸BISSCHEDULE A - OCCUPANCY / USE2
09/03/2020321730748Open ↗
04/27/2018321730748Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
01/25/2021321730748Open ↗
▸BISDCAS DEED RESTRICTION: APPROVAL1
04/27/2018321730748Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
04/27/2018321730748Open ↗
▸Other Documents24
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone6
08/13/2026B00655671-P2Open ↗
08/13/2026B00655671-P4Open ↗
08/13/2026B00655671-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSite Survey: Initial6
08/13/2026B00655671-P2Open ↗
08/13/2026B00655671-P3Open ↗
08/13/2026B00655671-P4Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlot Diagram6
08/13/2026B00655671-P4Open ↗
08/13/2026B00655671-P3Open ↗
08/13/2026B00655671-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProperty Ownership Certification3
08/28/2026B00655671-P4Open ↗
08/28/2026B00655671-P1Open ↗
08/15/2026B00655671-I1Open ↗
▸BISPLOT DIAGRAM1
04/27/2018321730748Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00655671-I1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026B00655671-I1Open ↗