← Back
One story retail building
2556 BOSTON ROAD
BRONX · BIN 2095041
💬 Discuss this project
1931Year Built
4Stories
K1Building Class
C8-1Zoning
5,340 sfGross Floor Area
4Units
0 Open Violations
One story retail building · Owner of record: BOSTON 1 LLC · 8,108 sf lot · 0.66 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Roof3p · 1 filing · 14 docs
Floor 19p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CHESTNUT HOLDINGS604/09/2026
AMERICAN PROTECTION SERVICES303/22/2026
2550 BOSTON POST ROAD COR903/22/2026
BOSTON 1 LLC103/22/2026
2550 BOSTON ROAD CORP203/22/2026
2550 REALTY2203/22/2026
2527 BOSTON POST RD103/22/2026
BOSTON ROAD ASSOC.103/22/2026
2556 BOSTON FOOD403/21/2026
LB NORTH EAST DEVELOPERS LTD.903/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AYALA ENGINEERING PC301/27/2025
PROENGINEERING112/09/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PNP MANAGEMENT AND CONSULTING INC203/21/2026
SUN203/21/2026
YBL NY203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALL PRO PLBG & HTG INCPlumbing507/08/2026
AMERICAN PROTECTION SERVIGeneral Contractor303/21/2026
BG CONSTRUCTION NY INCGeneral Contractor303/21/2026
ANTON NICAJElectrical103/21/2026
TREVOR DUNWELLElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AYALA ENGINEERING P.C.9207301/27/2025
ARC-HI-TECH ASSOCIATES IN6963112/09/2024
Building Lifecycle
All (47)Filed (4)Permit Issued (3)Violation (22)Inspection (7)Special Inspection (11)
08/08/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/18/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/16/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/23/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/10/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/10/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/21/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/30/2025
Permit issued — Mechanical Systems
X01127388-S1-MS
01/27/2025
Filed — Alteration
Job filed existing commercial store to install commercial kitchen hood and fire suppression system . No change of use, egress or occupancy under this application.
X01127388-P1
01/27/2025
Filed — Alteration
Job filed existing commercial store to install commercial kitchen hood and fire suppression system . No change of use, egress or occupancy under this application.
X01127388-S1
01/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Pablo Ayala
01/22/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Pablo Ayala
01/21/2025
Special inspection requirement — Mechanical Systems
Pablo Ayala
01/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Pablo Ayala
01/21/2025
Special inspection requirement — Final
Pablo Ayala
01/21/2025
Special inspection requirement — Energy Code Compliance Inspections
Pablo Ayala
01/21/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Pablo Ayala
12/16/2024
Permit issued — Plumbing
X01127388-I1-PL
12/16/2024
Permit issued — Mechanical Systems
X01138710-I1-MS
12/09/2024
Filed — Alteration
X01138710-I1
12/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
IGOR LISOVENKO
12/05/2024
Special inspection requirement — Duct leakage testing, insulation and design
IGOR LISOVENKO
12/03/2024
Filed — Alteration
Job filed existing commercial store to install commercial kitchen hood and fire suppression system . No change of use, egress or occupancy under this application.
X01127388-I1
11/06/2024
Special inspection requirement — Mechanical Systems
IGOR LISOVENKO
11/06/2024
Special inspection requirement — Final
IGOR LISOVENKO
07/28/2023
Violation issued (ECB, closed)
Construction
01/19/2016
Violation issued (ECB, closed)
Construction
02/14/2014
Violation issued (ECB, closed)
Unknown
01/19/2013
Violation issued (ECB, closed)
Construction
02/23/2010
Violation issued (ECB, closed)
Construction
10/26/2009
Violation issued (ECB, closed)
Construction
01/26/2009
Violation issued (ECB, closed)
Construction
11/25/2008
Violation issued (ECB, closed)
Construction
07/12/2008
Violation issued (ECB, closed)
Construction
03/12/2007
Violation issued (ECB, closed)
Construction
11/28/2006
Violation issued (ECB, closed)
Construction
04/18/2006
Violation issued (ECB, closed)
Construction
11/17/2004
Violation issued (ECB, closed)
Construction
02/26/2002
Violation issued (ECB, closed)
Construction
02/26/2002
Violation issued (ECB, closed)
Construction
02/26/2002
Violation issued (ECB, closed)
Construction
05/14/1996
Violation issued (ECB, closed)
Construction
01/05/1994
Violation issued (ECB, closed)
Construction
08/31/1992
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
05/09/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/09/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/09/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedBG CONSTRUCTION NY INC01/30/2025
DOB NOWPlumbingPermit IssuedALL PRO PLBG & HTG INC12/16/2024
DOB NOWMechanical SystemsPermit IssuedAMERICAN PROTECTION SERVI12/16/2024
BISFPISSUEDSUPERIOR FIRE CONTROL INC03/11/2019
BISPLISSUEDORBIT PLBG & HTG INC01/29/2019
BIS—ISSUEDGIM CONSTRUCTION INC10/31/2018
BISPLISSUEDTHE PLBG & HTG SPECIALIST07/20/2015
BISPLISSUEDVITELLO P & MECHANICAL INC02/06/2014
BISOTISSUEDL.B. NORTH EAST DEV. LTD05/18/2009
BISOTISSUEDL.B. NORTHEAST DEVELOPER LTD08/03/2005
BISOTISSUEDL.B. NORTHEAST DEVELOPER PC07/29/2005
BISCCISSUEDLB NORTHEAST DEVELOPERS LTD06/03/2005
BIS—ISSUEDDCT INC12/23/2003
BISFPISSUEDMASTER FIRE SYSTEMS, INC10/03/2003
BISPLISSUEDNATIONWIDE MECHANICAL INC09/19/2003
BISOTISSUEDDCT., INC.09/16/2003
BISPLISSUEDL.L.G. PLBG & HTG INC12/17/2002
BIS—ISSUEDC.I. CONTRACTING CORP10/23/2002
BIS—ISSUEDC.I. CONTRACTING CORP07/24/2002
BISEQISSUEDC.I. CONTRACTING CORP07/24/2002
BISPLISSUEDL.L.G. PLBG & HTG INC03/25/2002
BIS—ISSUEDC.I. CONTRACTING CORP03/12/2002
BISEQISSUEDC.I. CONTRACTING CORP03/12/2002
BISOTISSUEDC.I. CONTRACTING CORP11/07/2001
BISOTISSUEDC.I. CONTRACTING CORP05/11/2001
BISOTISSUEDL.B. NORTH EAST DEVELOPERS LTD.02/10/2000
1 project · most recent 01/27/2025
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/27/2025Permit IssuedBG CONSTRUCTION NY INCVentilation Systems
Ventilation
Captiveaire DU50HFA 36,000 CFM · Exhaust Fan ×2
EA1-D.250-16Z 36,000 CFM · Makeup Air ×2
1 project · most recent 01/27/2025
Gas Water/Sanitary
FiledStatusContractorScope
01/27/2025Permit IssuedALL PRO PLBG & HTG INCGas, Water/Sanitary
1 project · most recent 11/11/2018
General Wiring
FiledStatusContractorScope
11/11/2018Permit IssuedACCURATE ELEC'L CORP.General Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
08/08/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/18/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/16/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/23/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/10/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/10/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/21/2025Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
01/27/2025Fire-Resistant Penetrations and JointsPablo Ayalaspecial
01/22/2025Fire-Resistant Penetrations and JointsPablo Ayalaspecial
01/21/2025Mechanical SystemsPablo Ayalaspecial
01/21/2025Fire-Resistant Penetrations and JointsPablo Ayalaspecial
01/21/2025FinalPablo Ayalaprogress
01/21/2025Energy Code Compliance InspectionsPablo Ayalaprogress
01/21/2025HVAC-R and service water piping design and insulationPablo Ayalaenergy_progress
12/07/2024Fire-Resistant Penetrations and JointsIGOR LISOVENKOspecial
12/05/2024Duct leakage testing, insulation and designIGOR LISOVENKOenergy_progress
11/06/2024Mechanical SystemsIGOR LISOVENKOspecial
11/06/2024FinalIGOR LISOVENKOprogress
▾Documents — 122 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/20/2026X01138710-I1Request digital key ↗
08/20/2026X01127388-P1Request digital key ↗
08/20/2026X01127388-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits24
▸BISPLAN / WORK APPROVAL APPLICATION18
03/05/2019220628471Open ↗
03/05/2019220628471Open ↗
02/27/2019220692141Open ↗
Showing 3 of 18 on file for this type
▸BISWORK PERMIT APPLICATION6
03/11/2019220692141Open ↗
01/29/2019220628471Open ↗
11/01/2018220628471Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications30
▸BISPROFESSIONAL CERTIFIED CHECKLIST7
02/27/2019220692141Open ↗
12/18/2017220628471Open ↗
12/18/2017220628471Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
05/08/2019220692141Open ↗
02/27/2019220692141Open ↗
12/18/2017220628471Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
02/27/2019220692141Open ↗
12/18/2017220628471Open ↗
05/03/2016220529612Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/20/2026X01127388-P1Open ↗
08/20/2026X01127388-I1Open ↗
08/20/2026X01127388-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/27/2026X01138710-I1Open ↗
08/27/2026X01138710-I1Open ↗
08/23/2026X01127388-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/27/2026X01138710-I1Open ↗
08/26/2026X01127388-P1Open ↗
08/24/2026X01127388-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
05/14/2009220006730Open ↗
▸Trade Schedules & Equipment13
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE6
02/06/2019220628471Open ↗
12/18/2017220628471Open ↗
05/03/2016220529612Open ↗
Showing 3 of 6 on file for this type
▸BISSELF-CERT PLUMBING NOTICE3
07/09/2014220006730Open ↗
07/02/2014220006730Open ↗
03/19/2014220006730Open ↗
▸BISSCHEDULE B - PLUMBING3
07/08/2014220006730Open ↗
08/20/2009220006730Open ↗
05/14/2009220006730Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
05/08/2019220692141Open ↗
▸Safety & Tenant Protection3
▸BISSTREET TREE CHECKLIST2
10/12/2018220628471Open ↗
06/15/2015220463344Open ↗
▸BISTenant Protection Plan and Notes1
12/18/2017220628471Open ↗
▸Environmental & Asbestos10
▸BISASBESTOS: CERTIFICATION (DEP ACP5)5
02/27/2019220692141Open ↗
12/18/2017220628471Open ↗
05/03/2016220529612Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/20/2026X01127388-P1Open ↗
08/20/2026X01127388-I1Open ↗
08/20/2026X01127388-S1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
05/14/2009220006730Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS5
04/04/2018220628471Open ↗
05/03/2016220529612Open ↗
04/14/2016220463344Open ↗
Showing 3 of 5 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS1
04/12/2016220463344Open ↗
▸Approvals, Objections & Sign-offs8
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
07/02/2019220692141Open ↗
05/08/2019220692141Open ↗
04/14/2016220463344Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE2
03/20/2018220628471Open ↗
12/18/2017220628471Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
05/14/2009220006730Open ↗
▸Cost, Insurance & Ownership10
▸BISCOST AFFIDAVIT10
05/08/2019220692141Open ↗
02/27/2019220692141Open ↗
04/04/2018220628471Open ↗
Showing 3 of 10 on file for this type
▸Filing & Intake Forms13
▸BISADDITIONAL INFORMATION6
03/05/2019220628471Open ↗
02/06/2019220628471Open ↗
11/01/2018220628471Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING COVER SHEET5
02/27/2019220692141Open ↗
12/18/2017220628471Open ↗
05/03/2016220529612Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM2
07/02/2019220692141Open ↗
05/08/2019220692141Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
12/18/2017220628471Open ↗